Siemens 6AV7894-0CB00-0AA0 SIMATIC HMI IPC677C Panel PC

SKU 6AV7894-0CB00-0AA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7894-0CB00-0AA0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371098

  • Payment: T/T, Western Union

  • Weight: 17450g

  • Dimensions: To be determined

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7894-0CB00-0AA0 is a SIMATIC HMI IPC677C Panel PC, designed for industrial human-machine interface (HMI) applications. This unit integrates a 19-inch touch display with a resolution of 1280x1024 pixels, featuring a front-side USB interface for convenient access. It is equipped with a Celeron P4505 processor (2 cores/2 threads, 1.86 GHz, 2 MB cache), 1 GB DDR3 1066 DIMM RAM, and a 250 GB SATA HDD. Connectivity options include two 10/100/1000 Mbit/s Ethernet ports, four USB V2.0 ports, and one serial (COM1) port. For fieldbus communication, it supports PROFIBUS/MPI, compatible with CP 5611-A2. The system also features a watchdog, temperature, and fan monitoring, along with an onboard RAID controller. Power is supplied via a 110/230 V AC unit with NAMUR, provided without a line cable. It includes 2 MB buffered SRAM and two free PCI slots, delivered without an operating system or expansion software.

Features

  • 19-inch Touch Display with 1280x1024 Resolution
  • Celeron P4505 Processor (2C/2T, 1.86 GHz, 2 MB Cache)
  • 1 GB DDR3 1066 DIMM RAM and 2 MB Buffered SRAM
  • 250 GB SATA Hard Disk Drive
  • Dual 10/100/1000 Mbit/s Ethernet Interfaces
  • Multiple USB V2.0 Ports (4x rear, 1x front-side)
  • One Serial (COM1) Interface
  • PROFIBUS/MPI (CP 5611-A2-compatible) Communication
  • Integrated Watchdog, Temperature, and Fan Monitoring
  • Onboard RAID Controller
  • Two Free PCI Expansion Slots
  • 110/230 V AC Power Supply Unit with NAMUR

Applications

The Siemens SIMATIC HMI IPC677C Panel PC is suitable for a wide range of industrial automation applications requiring robust HMI functionality, data processing, and communication capabilities. Typical deployments include:

  • Machine control and visualization
  • Process monitoring and data acquisition
  • Operator stations in manufacturing plants
  • Building automation systems
  • Logistics and material handling systems
  • Distributed control systems (DCS) interfaces

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange IPC677C
Type of Product PC panels
PLM Product Phase Phase-Out
Display Size 19 inches
Display Type Touch
Display Resolution 1280 x 1024 pixels
Processor Celeron P4505 (2C/2T, 1.86 GHz, 2 MB Cache)
RAM 1 GB DDR3 1066 DIMM
Buffered SRAM 2 MB
Storage 250 GB HDD SATA
Optical Drive None
Ethernet Ports 2x 10/100/1000 Mbit/s
USB Ports 4x USB V2.0 (rear), 1x USB (front-side)
Serial Ports 1x (COM1)
Fieldbus Interface PROFIBUS/MPI (CP 5611-A2-compatible)
Expansion Slots 2x PCI (free)
Power Supply 110/230 V AC (with NAMUR)
Monitoring Watchdog, Temperature, Fan
RAID Controller Onboard
Operating System None
Expansion Software None
Commodity Code 85371098
Export Control Regulations (ECCN) N
Country of Origin To be determined
Package Dimensions (Calculated) To be determined
Shipping Weight 17.45 kg

Connections / Interfaces

Connector Type Function / Quantity
Ethernet 2x 10/100/1000 Mbit/s
USB V2.0 4x (rear panel)
USB 1x (front-side)
Serial 1x (COM1)
PROFIBUS/MPI 1x (CP 5611-A2-compatible)
PCI 2x (free expansion slots)

Installation Guidelines

  1. Safety First: Ensure all power to the system and connected components is de-energized and locked out before beginning installation or maintenance.
  2. Mounting: Mount the Panel PC securely into a suitable panel cutout or enclosure, ensuring proper ventilation and access to ports.
  3. Power Connection: Connect the 110/230 V AC power supply unit. Ensure the power cable (not included) is correctly rated and securely terminated. Adhere to NAMUR guidelines for power supply integration if applicable to your system.
  4. Grounding: Establish a robust protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Ethernet Connections: Connect industrial Ethernet cables to the 10/100/1000 Mbit/s ports for network communication. Use shielded cables in noisy industrial environments.
  6. USB and Serial Peripherals: Connect USB devices (e.g., keyboard, mouse, storage) to the available USB V2.0 ports. Utilize the COM1 serial port for compatible serial devices.
  7. PROFIBUS/MPI Connection: If using PROFIBUS/MPI, connect the appropriate bus cable to the interface. Ensure correct termination and addressing according to the PROFIBUS/MPI network specifications.
  8. Cooling: Ensure adequate airflow around the Panel PC to prevent overheating, especially given its fan monitoring capabilities. Do not obstruct ventilation openings.
  9. Initial Power-Up: After all connections are verified, re-energize the system. Monitor the Panel PC for proper boot-up and system status indicators.

FAQ

What type of display does the 6AV7894-0CB00-0AA0 feature?

It features a 19-inch touch display with a resolution of 1280x1024 pixels, including a front-side USB interface.

What processor is used in this Panel PC?

The Panel PC is equipped with a Celeron P4505 processor, which has 2 cores/2 threads, operates at 1.86 GHz, and includes a 2 MB cache.

Does this unit come with an operating system?

No, the 6AV7894-0CB00-0AA0 is delivered without an operating system or any expansion software.

What communication interfaces are available?

It provides two 10/100/1000 Mbit/s Ethernet ports, four rear USB V2.0 ports, one front-side USB port, one serial (COM1) port, and a PROFIBUS/MPI interface compatible with CP 5611-A2.

What is the power supply requirement for this Panel PC?

The unit requires a 110/230 V AC power supply unit with NAMUR, though the line cable is not included.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.