Siemens

Siemens 6ES7710-3DA03-1FB1 SIMATIC Field PG Programming Device

SKU 6ES7710-3DA03-1FB1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7710-3DA03-1FB1

  • Country of origin:Germany

  • Product Type: Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 29.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7710-3DA03-1FB1 is a SIMATIC Field PG programming device, designed for the configuration, programming, and diagnostics of Siemens SIMATIC automation systems. This unit features a Pentium III 850 MHz processor with a 256 KB 2nd level cache, 64 MB of SDRAM, and a 30 GB EIDE hard disk drive. It includes an integrated DVD/CD ROM drive and a Superdisk LS 240 drive for data transfer and media access. The device comes pre-installed with the Windows 2000 MUI GEFSI operating system and essential Siemens programming software, including STEP 7 Professional, STEP 5, and STEP 7 MicroWIN, making it ready for immediate use in industrial automation environments. A power cable suitable for various European regions (GER, FR, NL, SP, BEL, AUSTRIA, SWD, FIN) is also included.

Features

  • Pentium III 850 MHz Processor
  • 256 KB 2nd Level Cache
  • 64 MB SDRAM (1x64 MB)
  • 30 GB EIDE Hard Disk Drive
  • Integrated DVD/CD ROM Drive
  • Integrated Superdisk LS 240 Drive
  • Pre-installed Windows 2000 MUI GEFSI Operating System
  • Pre-installed Siemens STEP 7 Professional, STEP 5, and STEP 7 MicroWIN Software
  • Includes regional power cable for specified European countries

Applications

  • Programming and configuration of Siemens SIMATIC S7, S5, and MicroWIN PLCs.
  • Diagnostics and troubleshooting of industrial automation systems.
  • On-site commissioning and maintenance tasks for Siemens-based control systems.
  • Development and testing of automation projects.

Technical Specifications

Manufacturer Siemens
Product Range SIMATIC Field PG
Product Sub-Range Field PG
Product Type Pentium III Programming Device
Processor Pentium III 850 MHz
Cache 256 KB 2nd Level Cache
RAM 64 MB SDRAM (1x64 MB)
Hard Drive 30 GB EIDE HDD
Optical Drive DVD / CD ROM Drive
Floppy Drive Superdisk LS 240 Drive
Operating System Windows 2000 MUI GEFSI
Pre-installed Software STEP 7 Professional, STEP 5, STEP 7 MicroWIN
Software Installation Date 08/2001
Product Lifecycle Status Phase-Out
Package Dimensions (Calculated) 29.00 x 25.00 x 25.00 cm
Shipping Weight 4.00 kg
Commodity Code 84713000
Export Control Classification Number (ECCN) N

Installation Guidelines

  1. Power Connection: Connect the provided power cable to a suitable mains supply according to local electrical standards. Ensure the power source matches the device's voltage requirements.
  2. Environmental Considerations: Operate the Field PG in a clean, dry environment within its specified temperature and humidity ranges to prevent damage. Avoid areas with excessive dust, vibration, or direct sunlight.
  3. Ventilation: Ensure adequate airflow around the device to prevent overheating. Do not block ventilation openings.
  4. Peripheral Connections: Connect any necessary external peripherals (e.g., programming cables, external monitors) to the appropriate ports.
  5. Initial Startup: Power on the device. The pre-installed operating system and software should be ready for use. Verify proper functionality before commencing programming tasks.
  6. Data Backup: Regularly back up critical project data to external storage to prevent loss.

FAQ

What is the primary function of the Siemens 6ES7710-3DA03-1FB1?

It is a SIMATIC Field PG programming device used for configuring, programming, and diagnosing Siemens SIMATIC automation systems, including S7, S5, and MicroWIN PLCs.

What operating system is pre-installed on this Field PG?

The device comes with Windows 2000 MUI GEFSI pre-installed.

Which Siemens programming software is included with the device?

It includes pre-installed STEP 7 Professional, STEP 5, and STEP 7 MicroWIN software.

What are the main storage components of this programming device?

The Field PG features a 30 GB EIDE hard disk drive, an integrated DVD/CD ROM drive, and a Superdisk LS 240 drive.

What is the product lifecycle status of this device?

The Siemens 6ES7710-3DA03-1FB1 is currently in the Phase-Out stage of its product lifecycle.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...