Description

The 6GK1102-0AB00 is a SINEC H1 SSV 102 B fan-out unit designed to facilitate network expansion within industrial communication architectures. This unit features 5 interfaces and is specifically designed for 19-inch mounting rack installation, providing a centralized point for connecting multiple H1 network nodes. As a key component of the legacy SINEC H1 communication system, it supports reliable data distribution in industrial environments.

Features

  • System Type: SINEC H1 SSV 102 B Fan-Out Unit
  • Interfaces: 5 integrated interfaces
  • Mounting: 19-inch rack-mount design
  • Function: Industrial network expansion and signal distribution

Applications

  • Legacy industrial network infrastructure
  • SINEC H1 network node distribution
  • Centralized industrial communication rack systems

Technical Specifications

Feature Specification
Manufacturer Siemens
Brand Siemens
Product Range Sinec
Product Type Communication modules
Interfaces 5
Mounting 19-inch rack
Dimensions 26.00 cm x 25.50 cm x 12.50 cm
Weight 2.70 kg
Product Phase Obsolete

Installation Guidelines

  • Mounting: Designed for secure installation in a standard 19-inch industrial communication rack. Ensure proper mechanical fastening to support the weight of the unit.
  • Wiring: Connect the H1 network cables to the 5 available interfaces. Ensure proper shielding and connector seating to maintain signal integrity across the H1 bus.
  • Grounding: Connect the unit chassis to the rack ground to minimize electromagnetic interference and ensure safe operation within the electrical cabinet.
  • Ventilation: While compact, ensure adequate airflow within the rack to prevent internal component degradation over extended operation.
  • Compatibility: Verify system-wide compatibility with existing SINEC H1 network infrastructure prior to integration.

FAQ

What is the primary function of the 6GK1102-0AB00?

It serves as a fan-out unit for the SINEC H1 industrial communication network, allowing for the connection of multiple network nodes.

How many interfaces does this unit provide?

The unit is equipped with 5 interfaces.

Is this unit compatible with a standard 19-inch rack?

Yes, it is designed specifically for 19-inch rack-mount installations.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany
Power source
DC Power

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.