Siemens

Siemens 6SE7016-2FB87-1FD0 SIMOVERT MASTERDRIVES du/dt Filter

SKU 6SE7016-2FB87-1FD0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6SE7016-2FB87-1FD0
  • Origin Germany
  • Product Type: du/dt Filter
  • Barcode: 85049099
  • Payment: T/T, Western Union
  • Weight: 0.02 kg
  • Dimensions: 48.30cm x 40.60cm x 35.60cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

The 6SE7016-2FB87-1FD0 is a SIMOVERT MASTERDRIVES du/dt filter designed to protect motor insulation and extend the operational lifespan of drive systems. By reducing voltage rise times (du/dt) at the output of frequency inverters, this filter mitigates high-frequency voltage peaks that can lead to premature motor failure. It is compatible with three-phase supply configurations, supporting 380–460 V AC at 6.1 A or 500–575 V AC at 6.2 A, ensuring versatility across different industrial power architectures.

Features

  • Protection: Reduces steep voltage slopes (du/dt) to protect motor windings and insulation systems.
  • Compatibility: Designed for use with SIMOVERT MASTERDRIVES inverter configurations.
  • Current Ratings: Supports 6.1 A at 380–460 V AC and 6.2 A at 500–575 V AC.
  • Robust Design: Industrial-grade construction suitable for continuous operation in demanding production environments.
  • Flexibility: Acts as a base unit for drive systems, allowing for additional technical options.

Applications

  • Protection of AC motors in high-frequency switching drive environments.
  • Extension of cable lengths between inverters and motors.
  • Industrial production lines utilizing SIMOVERT MASTERDRIVES power sections.
  • Retrofitting and maintenance of legacy automation drive systems.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range SIMOVERT
Subrange MASTERDRIVES
Device Type du/dt Filter
Input Voltage (1) 380-460 V AC
Rated Current (1) 6.1 A
Input Voltage (2) 500-575 V AC
Rated Current (2) 6.2 A
Dimensions (WxHxD) 48.30 x 40.60 x 35.60 cm
Weight 20.00 kg
Commodity Code 85049099

Installation Guidelines

  • Positioning: Install the filter as close to the inverter output as possible to minimize the length of unfiltered cable runs.
  • Cooling: Ensure adequate ventilation in the control cabinet; the filter generates heat during operation and requires unobstructed airflow.
  • Grounding: Maintain high-quality electrical grounding connections to ensure effective suppression of electromagnetic interference and safe operation.
  • Wiring: Use shielded cabling for connections between the filter and the motor to comply with electromagnetic compatibility (EMC) standards.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary purpose of the 6SE7016-2FB87-1FD0?
It is a du/dt filter that reduces high voltage peaks and steep voltage rises at the inverter output, protecting motor insulation.
Can this filter be used on different voltage systems?
Yes, it supports 380-460 V AC at 6.1 A and 500-575 V AC at 6.2 A.
Are there additional configurations available for this base drive?
Yes, the module serves as a base configuration, and additional technical options may be available depending on specific application needs.
Reviews

6SE7016-2FB87-1FD0

Stock & lead time on request

Call
1 of 6

Siemens 6SE7016-2FB87-1FD0 SIMOVERT MASTERDRIVES du/dt Filter

Only 8 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6SE7016-2FB87-1FD0

  • Country of origin:Germany

  • Product Type: du/dt Filter

  • Barcode: 85049099

  • Payment: T/T, Western Union

  • Weight: 20g

  • Dimensions: 48.30cm x 40.60cm x 35.60cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

The 6SE7016-2FB87-1FD0 is a SIMOVERT MASTERDRIVES du/dt filter designed to protect motor insulation and extend the operational lifespan of drive systems. By reducing voltage rise times (du/dt) at the output of frequency inverters, this filter mitigates high-frequency voltage peaks that can lead to premature motor failure. It is compatible with three-phase supply configurations, supporting 380–460 V AC at 6.1 A or 500–575 V AC at 6.2 A, ensuring versatility across different industrial power architectures.

Features

  • Protection: Reduces steep voltage slopes (du/dt) to protect motor windings and insulation systems.
  • Compatibility: Designed for use with SIMOVERT MASTERDRIVES inverter configurations.
  • Current Ratings: Supports 6.1 A at 380–460 V AC and 6.2 A at 500–575 V AC.
  • Robust Design: Industrial-grade construction suitable for continuous operation in demanding production environments.
  • Flexibility: Acts as a base unit for drive systems, allowing for additional technical options.

Applications

  • Protection of AC motors in high-frequency switching drive environments.
  • Extension of cable lengths between inverters and motors.
  • Industrial production lines utilizing SIMOVERT MASTERDRIVES power sections.
  • Retrofitting and maintenance of legacy automation drive systems.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range SIMOVERT
Subrange MASTERDRIVES
Device Type du/dt Filter
Input Voltage (1) 380-460 V AC
Rated Current (1) 6.1 A
Input Voltage (2) 500-575 V AC
Rated Current (2) 6.2 A
Dimensions (WxHxD) 48.30 x 40.60 x 35.60 cm
Weight 20.00 kg
Commodity Code 85049099

Installation Guidelines

  • Positioning: Install the filter as close to the inverter output as possible to minimize the length of unfiltered cable runs.
  • Cooling: Ensure adequate ventilation in the control cabinet; the filter generates heat during operation and requires unobstructed airflow.
  • Grounding: Maintain high-quality electrical grounding connections to ensure effective suppression of electromagnetic interference and safe operation.
  • Wiring: Use shielded cabling for connections between the filter and the motor to comply with electromagnetic compatibility (EMC) standards.
Key Features:

What is the primary purpose of the 6SE7016-2FB87-1FD0?

It is a du/dt filter that reduces high voltage peaks and steep voltage rises at the inverter output, protecting motor insulation.

Can this filter be used on different voltage systems?

Yes, it supports 380-460 V AC at 6.1 A and 500-575 V AC at 6.2 A.

Are there additional configurations available for this base drive?

Yes, the module serves as a base configuration, and additional technical options may be available depending on specific application needs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors differently. Compare current ripple, low-speed torque, field control, feedback, reversing, braking energy, electromagnetic effects, and retrofit risks...