Product Overview

The X20PD2113 (X20PD2113) is a specialized digital output module within the B&R X20 system, designed for high-performance switching in decentralized automation architectures. Unlike standard source modules, the X20PD2113 features 6 digital outputs utilizing sink connection technology. This configuration is essential for interfacing with specific industrial actuators and electronic loads that require a ground-switching (NPN) logic. Engineered for the 24 VDC signal environment, this module provides a robust solution for machine builders in the printing, textile, and electronics assembly sectors where precision timing and specific electrical compatibility are required to maintain high throughput and minimize operational latency.

Technical Configuration

The X20PD2113 hardware is built to provide maximum electrical reliability across its 6 output channels. In a sink configuration, the module acts as a switch to the negative potential (0 VDC), allowing current to flow from the load through the module to the common ground. This is a critical requirement for integrating the B&R X20 system with third-party sensors or specialized valve manifolds that operate on NPN logic. Each channel is designed to handle a 24 VDC signal supply, and the module integrates seamlessly with the X20 backplane, providing real-time diagnostics to the central PLC. This allows for immediate detection of communication loss or power supply fluctuations, ensuring that the safety and logic integrity of the system remain uncompromised.

Technical Specifications

Feature Specification Details
Model X20PD2113
Brand B&R Industrial Automation
Module Type Digital Output Module
Number of Outputs 6
Connection Type Sink (NPN switching)
Signal Supply 24 VDC
I/O Grid X20 System
Protection Rating IP20
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Weight Approx. 0.06 kg (Net)
Shipping Weight 1.5 kg

Technical FAQs

What is the primary difference between the X20PD2113 and a standard source module?

The X20PD2113 is a "Sink" module, meaning it switches the ground (negative) side of the load. Standard "Source" modules switch the positive 24 VDC side. You must ensure your field device is compatible with NPN (Sink) logic to prevent short circuits or non-operation.

How does the 6-output configuration affect the process image?

The module occupies a specific bit-width in the X20 process image. In the PLC configuration (Automation Studio), these 6 outputs are mapped to digital bits, allowing for direct logical control. Diagnostic bits are also available to monitor the internal status of the module.

Can I mix Sink and Source modules in the same X20 rack?

Yes. One of the primary advantages of the X20 system is its modularity. You can install the X20PD2113 alongside source modules, analog modules, and safety modules on the same backplane, provided the total power consumption does not exceed the limit of the power supply module.


Engineering & Installation Guide

  • Sink Logic Wiring Safety: When wiring the X20PD2113, remember that the load is always "live" (connected to 24 VDC) and the module completes the circuit to ground. Ensure that the field wiring is properly insulated, as a stray wire touching the cabinet frame could inadvertently energize the actuator by creating an accidental path to ground.

  • Backplane Power Calculations: Before adding multiple X20PD2113 modules to a single bus segment, verify the current requirements for the internal X20 bus. If the total internal consumption of the I/O modules exceeds the capacity of the Bus Controller, an additional X20PS (Power Supply) module must be inserted to boost the backplane power.

  • Interference Mitigation: Since sink outputs are often used with high-speed electronic components, ensure that signal cables are kept away from high-power AC lines. Use shielded cables if the module is switching at high frequencies to prevent electromagnetic interference from affecting neighboring analog signals or communication lines.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.