Product Overview

The X67AO1323 (X67AO1323) is a ruggedized, field-mounted analog output module designed for decentralized automation environments. Featuring four high-precision outputs with a 0 to 20 mA signal range, this module is engineered to control actuators, variable frequency drives, and proportional valves directly at the machine level. With a 12-bit converter resolution and integrated reverse polarity protection, the X67AO1323 ensures reliable and stable signal transmission. Its IP67-rated construction (typical of the X67 series) makes it an ideal solution for harsh industrial conditions where cabinet space is limited and decentralized I/O is required to reduce wiring complexity and signal interference.

Technical Configuration

The hardware architecture of the X67AO1323 is optimized for 24 VDC power systems, operating efficiently within a broad voltage range of 18 to 30 VDC. The module utilizes a 12-bit digital-to-analog converter (DAC), providing a granular resolution of 4096 steps across the 0 to 20 mA range for smooth control loops. To ensure equipment safety, the module includes comprehensive protection against reverse polarity. Its thermal design is rated for extreme industrial temperatures, from -25 to 60 deg C, allowing it to be mounted directly on machinery in diverse climates. The high actuator power supply capacity of up to 12 W ensures that even demanding field devices receive consistent power without the need for additional auxiliary supply lines.

Technical Specifications

Parameter Specification
Model X67AO1323
Module Type Analog Output (Decentralized)
Number of Outputs 4
Signal Range 0 to 20 mA
Resolution 12-bit
Nominal Voltage 24 VDC
Voltage Range 18 to 30 VDC
Max. Power Consumption 12 W (Actuator Supply)
Operating Temp -25 to 60 deg C
Storage/Transport Temp -40 to 85 deg C
Net Weight 190 g
Shipping Weight 1.0 kg

Technical FAQs

Does the X67AO1323 require a separate power supply for the actuators?

The module is designed to provide power to the connected actuators directly through the X67 bus connection, up to a maximum of 12 W. However, you must verify that the total power consumption of all 4 connected devices does not exceed this 12 W limit to ensure stable operation.

How is the 12-bit resolution calculated for the 0-20 mA range?

The 12-bit resolution provides 4096 discrete steps. This means each step represents approximately 0.00488 mA (4.88 microamps). This level of precision is typically sufficient for most industrial flow control, speed regulation, and positioning tasks.

Is this module suitable for outdoor or washdown environments?

As an X67 series component, this module is built for field installation. While its operation temperature is broad (-25 to 60 deg C), ensure that all M12 connectors and unused ports are properly sealed with caps to maintain its environmental integrity against moisture and dust ingress.


Engineering & Installation Guide

  • Signal Shielding and M12 Connections: To maintain the 12-bit signal accuracy and prevent EMI interference, use shielded M12 cables for all analog outputs. The cable shield must be properly grounded through the M12 connector housing to the machine frame to ensure a low-impedance path for high-frequency noise.

  • Thermal and Mounting Considerations: Although the module is rated for up to 60 deg C, ensure it is not mounted directly against high-heat sources like large motors or industrial ovens. Natural convection should be allowed around the module housing to prevent localized overheating, especially when utilizing the full 12 W actuator power capacity.

  • Reverse Polarity and Wiring Safety: While the module features integrated reverse polarity protection for the 24 VDC supply, always verify the pinout of your M12 cables before applying power. Incorrect wiring of the current loop (0-20 mA) can lead to erratic actuator behavior or potential damage to the connected third-party devices.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...