1 de 6

ABB 3BSE013224R1 CI810V2 Advant S800 I/O AF100 Communication Interface

ABB 3BSE013224R1 CI810V2 Advant S800 I/O AF100 Communication Interface

Apenas 7 item(ns) restante(s) em estoque
  • Fabricante: ABB

  • Nº do Produto: 3BSE013224R1

  • País de origem:Suécia

  • Tipo de Produto: PLC Communication Modules

  • Código de barras: 85389091

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 25.0 x 12.0 x 10.0 cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Integrating seamless Advant Fieldbus 100 connectivity into distributed control architectures, the ABB 3BSE013224R1 CI810V2 functions as a high-speed communication interface for S800 I/O modules. This field communication interface acts as the local link master, managing exchange rates and diagnostic reporting between connected I/O clusters and upper-level Advant Controllers (such as AC 800M or AC 450). It delivers reliable cyclic data transmission and supports redundant configurations to maximize process uptime in heavy industrial automation systems.

Features

  • Provides physical and logical connection to the Advant Fieldbus 100 (AF100) twisted-pair network.
  • Supports up to 12 S800 I/O modules per cluster, handling both digital and analog signal types.
  • Equipped with comprehensive LED diagnostics on the front face for run, fail, and traffic status monitoring.
  • Supports hot-swap operation (Hot Configuration in Run) when paired with compatible module termination units.
  • Optoelectronic galvanic isolation ensures high electromagnetic compatibility (EMC) and protects internal logic.

Applications

  • Distributed Control Systems (DCS) in oil, gas, and petrochemical facilities.
  • Power generation and turbine control systems requiring deterministic process bus communication.
  • Pulp and paper mill processing lines with dense, localized analog and digital I/O clusters.
  • Water and wastewater plant control upgrades running legacy Advant S800 I/O networks.

Technical Specifications

Parameter Specification Value
Manufacturer ABB
Model Designation CI810V2
Article Number / SKU 3BSE013224R1
Protocol Type Advant Fieldbus 100 (AF100)
Supported I/O System S800 I/O Series
Nominal Supply Voltage 24 V DC (limits 19.2 V DC to 30 V DC)
Current Consumption 100 mA typical at 24 V DC
Isolation Voltage 50 V (galvanic isolation to I/O backplane)
Operating Temperature Range 0 to +55 degC (non-condensing)
Country of Origin Sweden
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 25.0 x 12.0 x 10.0 cm

Empirical Engineering Insights

Alternative Models & Compatibility

The CI810V2 directly replaces older legacy revisions (such as CI810V1) within existing S800 structures. When upgrading, ensure the system controller's system software/firmware supports the newer V2 module revision. While form-factor compatible, failing to align controller-side hardware configuration files can prevent module identification on the AF100 bus.

Application Pitfalls & Engineering Notes

Avoid running signal cables and the AF100 bus lines in the same wire ducts as high-power AC lines to prevent magnetic coupling. In high-temperature panels exceeding 45 degC, verify active air circulation, as the thermal build-up inside tightly enclosed clusters can degrade optical link stability when fiber-optic modems are coupled to the bus.

Commissioning & Wiring Tips

Always double-check that both termination resistors are in place at the physical ends of the AF100 bus network. An un-terminated or double-terminated bus leads to high reflection coefficients and diagnostic errors. Ensure that the module is completely clicked into its slot on the Module Termination Unit (MTU) before securing the screw terminals.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all 24 V DC system power sources before performing physical replacement or wiring on the communication module backplane. Working on an active system can cause transient bus faults, halting down-stream process controllers.

1

Configure the station address on the Module Termination Unit (MTU) rotary switches prior to slotting the CI810V2 interface module.

2

Align the module guides with the slots on the MTU and push firmly until the locking mechanisms click securely into place.

3

Terminate the AF100 twisted pair cable shield to the grounding rail using low-impedance ground clamps to prevent electromagnetic interference.

4

Restore 24 V DC power and verify that the "RUN" LED lights steady green, confirming that system initialization is successful.

How is the station address set for the CI810V2 module?

The station address is configured using the physical rotary switches located on the corresponding Module Termination Unit, such as the TU810 or TU812, rather than on the communication interface module itself.

Does this communication interface support hot-swapping?

Yes, the interface supports Hot Configuration in Run when installed on compatible dual-slotted or single-slotted termination units, allowing replacement without interrupting operational control.

What transmission media is supported by the AF100 interface?

The module interfaces with Advant Fieldbus 100 via twisted pair copper media directly, but can be adapted to fiber optic networks using external modems like the TC512 or TC513.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Suécia

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...