1 de 3

Allen-Bradley 1768-ENBT CompactLogix EtherNet/IP Communication Module

Allen-Bradley 1768-ENBT CompactLogix EtherNet/IP Communication Module

Apenas 3 item(ns) restante(s) em estoque
  • Fabricante: Allen-Bradley

  • Nº do Produto: 1768-ENBT

  • País de origem:Estados Unidos

  • Tipo de Produto: Ethernet Communication Module

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 213g

  • Dimensões: 132 x 56,7 x 105,1 mm (AxLxP)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

The 1768-ENBT is a CompactLogix EtherNet/IP Communication Module developed by Allen-Bradley to provide dedicated Ethernet networking capabilities for 1768 control systems. This module establishes reliable data transmission links across an industrial network, enabling seamless connectivity with multiple Logix5000 controllers, supervisory computers, and auxiliary automation equipment. It processes network traffic over a integrated communication interface while managing local status via an alphanumeric display and built-in diagnostic indicators. Designed as an open-type component, it installs directly within a synchronized hardware stack consisting of a 1768 controller and compatible power supplies to optimize throughput and minimize communication downtime.

Features

  • Provides automated data management over EtherNet/IP networks to reduce packet collisions and sustain optimal bandwidth.
  • Features an integrated alphanumeric display and three bi-color diagnostic status indicators (NET, Link, and OK) for rapid local troubleshooting.
  • Supports high-speed data transmission over standard Category 5 or Category 5e cabling using a rugged RJ45 connector interface.
  • Implements reliable electrical protection with a continuous functional insulation rating of 30V between the Ethernet network and internal system circuits.
  • Interfaces directly with specialized 1768 CompactLogix system components and supports flexible expansion using combined 1769-series I/O modules.

Applications

  • Distributed industrial automation and manufacturing plant network management.
  • Inter-controller data synchronization across multiple Logix5000 systems.
  • SCADA network routing and remote control system interface integration.

Technical Specifications

Parameter Specification
Backplane Current 834 mA at 5.2V DC
Power Consumption 4.34 W
Power Dissipation 4.38 W
Isolation Voltage 30V (continuous-voltage rating), Functional Insulation Type, Ethernet network to system (Type tested at 710V DC for 60 s)
Wire Size RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wiring Category 2 - on communication ports
North American Temp Code T4A
IEC Temp Code T4
Mounting Screw Torque 1.16 N.m (10 lb.in) using M4 or #8 screws
Dimensions (HxWxD), Approx. 132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.)
Weight, Approx. 0.213 kg (7.5 oz)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 5 g @ 10...500 Hz
Operating Shock 30 g
Nonoperating Shock 50 g
Emissions CISPR 11 Group 1, Class A
Enclosure Type Rating None (open-style)

Connections/Interfaces

Connector Pin Function
Pin 1 TD+ (Transmit Data +)
Pin 2 TD- (Transmit Data -)
Pin 3 RD+ (Receive Data +)
Pin 4 NC (No Connection)
Pin 5 NC (No Connection)
Pin 6 RD- (Receive Data -)
Pin 7 NC (No Connection)
Pin 8 NC (No Connection)

Installation Guidelines

  • Plan for a minimum hardware clearance of 105 mm (4 in.) at the top and bottom, and 90 mm (3.54 in.) on the sides from enclosure walls, wireways, and adjacent machinery.
  • Ensure the system is grounded through the DIN rail to the chassis ground by utilizing zinc-plated yellow-chromate steel DIN rail; avoid aluminum or plastic rails which can oxidize and cause poor conductivity.
  • Secure the mounting DIN rail to the surface approximately every 200 mm (7.87 in.) and install appropriate end-anchors to hold modules firmly.
  • If choosing panel mounting instead of DIN rail installation, mark pilot holes using the hardware as a template, drill holes for M4 or #8 screws, and tighten to 1.16 N.m (10 lb.in) of torque. Do not use screws and DIN rail concurrently.
  • Connect the network interface cable to a 100 MB Ethernet switch rather than a shared hub to increase network bandwidth and reduce lost packets.
  • Never connect or disconnect network communication cables while power is actively applied, as an electrical arc can occur and present an explosion hazard in certified environments.
  • Always wait for all diagnostic status lights on the power supply and controller to turn completely off before disconnecting any system module to allow the processor sufficient time to finish writing project parameters to non-volatile memory.
  • Mitigate static risks by touching a grounded object, wearing an approved grounding wriststrap, and strictly avoiding contact with component board pins, connectors, or internal circuit elements.

Compliance and Certifications

  • c-UL-us Listed Industrial Control Equipment, Certified for US and Canada (UL File E65584)
  • c-UL-us Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, Certified for US and Canada (UL File E194810)
  • CE Certified (European Union 2004/108/EC EMC Directive, compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2)
  • C-Tick Compliant (Australian Radiocommunications Act, compliant with AS/NZS CISPR 11)
  • Ex Certified (European Union 94/9/EC ATEX Directive, compliant with EN 60079-15 and EN 60079-0; II 3 G Ex nA IIC T4)
  • EtherNet/IP ODVA Conformance Tested
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1768-ENBT CompactLogix EtherNet/IP Communication Module

O que significa um status vermelho piscando no indicador NET?

Um indicador de rede (NET) vermelho piscando indica que uma ou mais das conexões estabelecidas nas quais o módulo de comunicação atua como dispositivo alvo expiraram o tempo de resposta.

Por que os instaladores devem esperar que todas as luzes de status se apaguem antes de separar o hardware?

Quando a energia do sistema é desligada, o controlador principal grava os dados do projeto ativo na memória não volátil. Separar os módulos antes que todas as luzes de status se apaguem interrompe esse processo, resultando na perda irreversível do programa de controle.

O que acontece se o indicador de status OK apresentar um padrão vermelho e verde piscando?

Um padrão vermelho e verde piscando no indicador OK indica que o módulo de comunicação está executando ativamente suas rotinas padrão de autoteste de inicialização.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Branco Acinzentado
Country of origin
Estados Unidos
Power source
Energia CC

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...