1 de 1

BECKHOFF C9900-E545 Control Panel Accessories Push-Button Extension

BECKHOFF C9900-E545 Control Panel Accessories Push-Button Extension

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: C9900-E545

  • País de origem:Alemanha

  • Tipo de Produto: Push-Button Extensions

  • Pagamento: T/T, Western Union

  • Peso: 5000g

  • Dimensões: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed to integrate directly onto the right-hand side of compatible operator interfaces, the C9900-E545 provides supplementary physical operator control elements for CP6xxx and CP7xxx series Control Panels and Panel PCs. This hardware extension is engineered specifically for 15-inch displays configured without integrated keyboards, delivering structured control feedback in demanding industrial environments.

The layout incorporates 16 illuminated push-buttons alongside a dedicated safety element. Operator signals utilize a dual-transmission design: primary control transmission and signal lamp illumination route via CP-Link or USB interfaces, while a terminal strip allows secondary hardwiring of normally-open contacts for critical process operations. Customizable label inserts permit site-specific marking of individual buttons to align with plant system configurations.

Features

  • Compatible with right-side mounting on 15-inch CP6x02-00xx and CP7x02-00xx panels.
  • Equipped with 16 square push-buttons (30 x 30 mm) featuring integrated signal lamps.
  • Includes 1 standard-compliant emergency stop button for direct integration into safety circuits.
  • Dual-contact output design: signals transmit via digital interface (CP-Link or USB) and via secondary direct terminal-row connection.
  • Removable caps enable custom physical labeling of all push-buttons.

Applications

  • Human-Machine Interface (HMI) expansion for CNC and machine tool control.
  • Automotive assembly line operator stations.
  • Specialty machine manufacturing requiring localized tactile controls and emergency stop functions.

Technical Specifications

ParameterSpecification
Manufacturer BECKHOFF
Part Number / Model C9900-E545
Compatibility CP6xxx and CP7xxx series Control Panels / Panel PCs (15-inch display without keyboard)
Mounting Location Right-hand side of the host panel
Push-Buttons 16 x illuminated push-buttons (Siemens Signum square, 30 x 30 mm)
Emergency Stop Switch 1 x Siemens Signum emergency stop (directly wireable)
Signal Interface CP-Link or USB (for primary contacts and signal lamps)
Auxiliary Interface Terminal row (for hardwiring second normally-open contacts)
Shipping Weight 5 kg

Connections and Interfaces

Interface Type Function Assignment
USB / CP-Link Connection Primary normally-open (NO) contact transmission and signal lamp control power.
Internal Terminal Strip Direct connection points for secondary normally-open (NO) contacts.
Emergency Stop Terminals Dedicated dry contact points for direct safety circuit integration.

Installation Guidelines

  • Ensure all power is disconnected from the main Control Panel or Panel PC prior to mounting the extension.
  • Align the structural fastening points on the right flange of the 15-inch panel housing to secure the mechanical link.
  • Route the USB/CP-Link internal cables to the host motherboard connectors without pinching.
  • Observe regional safety standards when wiring the emergency stop switch to the main safety monitoring relay.
Loading product navigation…

Which specific panels are compatible with the BECKHOFF C9900-E545?

The C9900-E545 is designed for mounting on the right-hand side of BECKHOFF CP6xxx and CP7xxx series Control Panels and Panel PCs with 15-inch displays that do not contain an integrated physical keyboard.

Can the emergency stop button be integrated into a safety PLC loop?

Yes, the emergency stop switch is designed to be directly wireable via independent terminals, allowing integration into standard safety relays or safety PLC architectures.

How are the 16 signal lamps powered and controlled?

The signal lamps are controlled and powered exclusively through the USB or CP-Link connection linked to the host system.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...