1 de 1

Beckhoff CX1100-0930 CX Series UPS Module

Beckhoff CX1100-0930 CX Series UPS Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: CX1100-0930

  • País de origem:Alemanha

  • Tipo de Produto: UPS Modules

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 95 mm x 100 mm x 91 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Integrating directly into the modular PC/104 bus architecture, the Beckhoff CX1100-0930 provides highly reliable, capacitive-based uninterruptible power supply capabilities for CX series Embedded PCs. This module is engineered to bridge short-term voltage fluctuations and secure volatile operational data by initiating a controlled shutdown sequence during primary power failures. By employing capacitive storage technology, it offers a maintenance-free alternative to traditional battery-backed systems, operating efficiently without risk of degradation or chemical leakage in harsh thermal environments.

Features

  • Capacitive Storage Medium: Features a 40 As capacity that eliminates regular battery maintenance intervals and shelf-life concerns.
  • Adjustable Retention Time: Provides load-dependent holdup durations that can be fully customized to meet specific system requirements.
  • Local Diagnostics indicators: Three integrated LEDs provide real-time status feedback for 24 V DC input, 24 V DC output, and capacitive charge state.
  • Embedded Bus Interface: Communicates directly via a high-speed, 16-bit ISA bus conforming to the standard PC/104 hardware layout.
  • Industrial Protection: IP20-rated housing built to resist severe industrial vibration and shock according to European standards.

Applications

  • Securing persistent memory (NOVRAM writing operations) during sudden primary power interruptions.
  • Enabling orderly, controlled OS shutdowns for Windows CE or Windows Embedded systems.
  • Protecting localized processing nodes in networks prone to voltage sags and grid fluctuations.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Article Number CX1100-0930
Input Voltage 24 V DC (-15% / +20%)
Storage Technology Capacitive
Capacity 40 As (Ampere-seconds)
Max. Output Current 2.0 A (at 24 V DC)
Charging Current Max. 4.0 A
Retention Time Adjustable, load-dependent
CPU Bus Interface 16-bit ISA (PC/104 standard)
Max. Power Loss 2.0 W
Diagnostic Displays LEDs for 24 V DC Input, 24 V DC Output, and Charge
Protection Rating IP20
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Dimensions (W x H x D) 95 mm x 100 mm x 91 mm
Net Weight 650 g
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The CX1100-0930 is mechanically and electrically dedicated to the legacy CX1000 and CX1020 Embedded PC systems. If replacing an older module or a battery-backed variant (such as the CX1100-0900 series), confirm that your operating system image contains the necessary registry settings to interact with the 16-bit ISA bus address allocation. This module will not directly interface with newer CX2000 systems using PCI Express-based system interfaces.

Application Pitfalls & Engineering Notes

Because this module utilizes capacitive storage, the 40 As total energy capacity is highly dependent on the total active current draw of the CPU stack. High processing loads or extensive connected I/O terminals during a power-fail transition will drastically shorten the retention window. System integrators must design efficient, non-blocking data-dump routines in TwinCAT to write persistent data (NOVRAM) to the boot media immediately upon detecting a mains failure signal.

Commissioning & Wiring Tips

During initial commissioning, verify that the 24 V DC power supply is sized to handle the maximum charging current overhead of 4.0 A. If the primary supply exhibits a voltage sag below 20.4 V DC (the lower limit of the -15% tolerance) during the module's charging phase, the system may initiate an unintentional low-voltage shutdown sequence. Check that the "Charge" LED switches from flashing (charging active) to solid green (fully charged) within the boot-up timeline.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all 24 V DC system power before executing assembly or disassembly. Capacitive units retain an electrical charge even after primary power disconnection. Allow a minimum of three minutes for internal energy dissipation before handling the physical bus connectors or dismantling the PC/104 block.

1

Align the CX1100-0930 interface with the adjoining CX series module, ensuring the 16-bit ISA (PC/104) male and female pin connectors match precisely without offset.

2

Slide the module onto the standard DIN rail until the locking latch clicks firmly, and secure the module stack together using the mechanical side-locking mechanism.

3

Connect the 24 V DC primary supply cables to the terminals, verifying polarity, and ensure a low-impedance connection to the central functional earth terminal.

4

Energize the power source and verify that the "Input" and "Charge" LEDs illuminate, indicating active voltage input and ongoing capacitive energy buffering.

Loading product navigation…

What is the primary operational advantage of the capacitive storage in the CX1100-0930?

Unlike traditional battery backup units, capacitive storage is maintenance-free, has a significantly longer operational lifespan, works across wider thermal ranges without degradation, and avoids hazardous leakage risks.

Does this module require software drivers to operate under TwinCAT?

Yes. Proper shutdown orchestration requires the installation and configuration of the Beckhoff UPS driver on the target operating system (e.g., Windows CE or Windows Embedded) connected via the PC/104 bus.

How long can the CX1100-0930 maintain power to the CPU?

The holdup duration is load-dependent. With a total capacity of 40 As (Ampere-seconds) and a maximum output current of 2.0 A, the actual backup window varies based on the current consumption of the active CPU and connected modules.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...