Description

Engineered for mounting directly on a standard 35 mm DIN rail in demanding industrial environments, the CX5240-N031-0001 functions as a compact, fanless Embedded PC powered by an Intel Atom® multi-core processor. This high-performance hardware platform is optimized for medium-to-large control tasks and data acquisition applications requiring local processing capabilities.

The unit features the factory-integrated N031 interface option, which provides a dedicated RS485 physical interface accessible via a 9-pin D-sub socket. This serial interface is configured as an endpoint with echo enabled and active line termination switched on, making it ready for reliable communication in multi-drop industrial network topologies. With direct backplane connection support, the controller serves as an intelligent master for EtherCAT Terminals or traditional Bus Terminals, enabling seamless integration into complex fieldbus configurations.

Features

  • Efficient, multi-core Intel Atom® processor execution for real-time control applications.
  • Integrated RS485 communication port (N031 configuration) with a 9-pin D-sub female connection.
  • Factory-configured endpoint setting with active termination and echo functionality.
  • Fanless design with passive convection cooling for high operational reliability and minimal maintenance.
  • Direct, modular expandability via Beckhoff I/O terminals (EtherCAT or Bus Terminals).
  • Robust housing design designed for standard DIN rail mounting in control cabinets.

Applications

  • Process automation and distributed machine control.
  • Serial communication networks utilizing localized RS485 Modbus RTU protocols.
  • Power generation monitoring and substation data aggregation.
  • Water and wastewater management systems requiring reliable, fanless PLC controllers.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model CX5240-N031-0001
Product Series CX5200 Series
Processor Type Intel Atom® processor
Interface Option N031 (RS485 interface)
Connector Type D-sub socket, 9-pin
RS485 Configuration Endpoint configuration, with echo, termination enabled
Cooling System Passive (fanless convection cooling)
I/O Terminal Connection Direct connection to EtherCAT Terminals (EL-series) or Bus Terminals (KL-series)
Shipping Weight 3.0 kg

Connections and Interfaces

D-sub 9-pin Connection Signal/Function Designation
Pin Layout RS485 Serial Interface (Endpoint, Echo On, Terminated)
Housing Connection Shield Ground

Installation Guidelines

  • Mounting: Mount the device horizontally on a standard 35 mm DIN rail (EN 60715) within an approved enclosure.
  • Thermal Management: Maintain a minimum clearance of 30 mm above and below the unit to ensure unimpeded air convection. Operating temperature limits must not exceed the specified ambient threshold.
  • Power & Grounding: Connect the functional earth terminal of the power supply connection directly to the mounting plate or DIN rail to optimize electromagnetic compatibility (EMC).
  • Signal Shielding: Use shielded cabling for the RS485 communication line and terminate the cable shield securely at the entry point of the control panel.
Loading product navigation…

What is the function of the N031 option on the Beckhoff CX5240-N031-0001?

The N031 option provides an integrated RS485 serial interface via a 9-pin D-sub socket. This interface is configured as an endpoint with active line termination and echo enabled.

Is the CX5240-N031-0001 actively cooled with internal fans?

No, this embedded PC features a completely fanless design relying on passive convection cooling, which improves hardware durability and reduces maintenance requirements.

Which I/O terminal systems are compatible with this device?

The unit supports direct, bus-side connection to both Beckhoff EtherCAT Terminals (EL series) and traditional Bus Terminals (KL series).

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...