1 de 1

BECKHOFF KS3142 Bus Terminal

BECKHOFF KS3142 Bus Terminal

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: KS3142

  • País de origem:Alemanha

  • Tipo de Produto: Bus Terminals

  • Pagamento: T/T, Western Union

  • Peso: 70g

  • Dimensões: 6.8 cm x 1.2 cm x 10.0 cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Acquisition of analog sensor signals within automated industrial networks is performed efficiently using the BECKHOFF KS3142 analog input terminal. This high-precision Bus Terminal provides dual-channel connection capabilities for field sensors operating with standard 0 to 20 mA signal currents. Utilizing a robust differential input design and a 16-bit analog-to-digital converter, the module delivers highly accurate measurement data directly to the K-bus process image. The distinctive feature of the KS-series housing is its pluggable wiring level, which enables fast assembly and easy replacement of the terminal block without disconnecting the established field-side wire connections.

Features

  • Two-channel analog input module processing 0 to 20 mA field signals.
  • High-resolution 16-bit analog-to-digital conversion with increased measuring accuracy.
  • Configurable conversion time and integral 50 Hz filter to eliminate signal noise.
  • Pluggable connection level allows quick terminal swapping during maintenance operations.
  • Differential inputs with 500 V galvanic isolation between the K-bus and field signals.
  • Integrated surge voltage resistance up to 35 V DC for enhanced field protection.

Applications

  • Machine building and precision assembly equipment
  • Industrial process instrumentation loops
  • Water and wastewater treatment facility monitoring
  • Power generation and thermodynamic plant controls

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model KS3142
Number of Inputs 2
Power Supply Via the K-bus
Signal Current 0 to 20 mA
Technology Differential input
Internal Resistance typ. 100 Ohm shunt
Common-mode Voltage (UCM) max. +/-10 V
Resolution 16 bit
Conversion Time 140 ms (configurable)
Filter 50 Hz (configurable)
Measuring Error < +/-0.05% (relative to full scale value)
Surge Voltage Resistance 35 V DC
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus typ. 85 mA
Bit Width in Process Image Input: 2 x 16-bit data (2 x 8-bit control/status optional)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Wiring Type Spring actuation by screwdriver (pluggable connector)
Connection Cross-section Solid/stranded: 0.08 to 1.5 mm², Fine-wire: 0.14 to 1.5 mm²
Connection Cross-section AWG Solid/stranded: AWG 28 to 16, Fine-wire: AWG 26 to 16
Stripping Length 9 to 10 mm
Current Load Power Contacts Imax: 10 A
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.07 kg

Installation Guidelines

  • Mounting: Snap directly onto a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking latch engages securely.
  • Wiring: Insert a small screwdriver into the clamp spring release slot to open the connection point, insert the stripped conductor (9 to 10 mm stripping length), and release the spring clamp.
  • Pluggable Block: Ensure the power supply is completely switched off before engaging or disengaging the pluggable terminal wiring block.
  • Shielding: Connect analog signal shields to the nearest functional ground bar to prevent environmental electromagnetic interference from affecting signal integrity.

Compliance and Certifications

  • CE
  • UL
  • ATEX
  • Ex Marking: II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What is the key advantage of the KS3142 pluggable wiring design?

The pluggable terminal block on the KS3142 allows the core unit to be unplugged and replaced during maintenance without having to disconnect or tag the individual signal lines.

Can the conversion times and filters of the KS3142 be adjusted?

Yes, both the conversion time (default 140 ms) and the internal 50 Hz filter parameters can be configured through the bus coupler software settings.

Does the KS3142 have standard ATEX ratings for hazardous locations?

Yes, the module is certified under ATEX with the Ex marking: II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...