Mitsubishi Electric GT2308-VTBA GOT2000 Series HMI

Mitsubishi Electric GT2308-VTBA GOT2000 Series HMI

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Mitsubishi Electric

  • Nº do Produto: GT2308-VTBA

  • País de origem:Estados Unidos

  • Tipo de Produto: HMI Touch Panels

  • Pagamento: T/T, Western Union

  • Peso: 8000g

  • Dimensões: 241 x 194 x 56 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed to streamline industrial process control and machine-level visualization, the Mitsubishi Electric GT2308-VTBA operates as a high-performance operator terminal within the GOT2000 Series. Featuring an 8.4-inch TFT color display, this Human-Machine Interface (HMI) delivers clear diagnostic data and system controls to plant floor operators, running on a 100 to 240VAC input power supply. The integration of high-resolution graphics and responsive analog resistive touch control ensures exact parameter adjustment in demanding environments.

Features

  • VGA Color Display: High-resolution 8.4-inch TFT display supporting 65,536 colors with an adjustable 16-level backlight intensity.
  • Versatile Communication: Integrated Ethernet, RS-232, and RS-422/485 serial ports to support multi-channel connectivity.
  • Robust Data Logging: Standard SD/SDHC card slot supporting up to 32GB of external storage for recipe, project, and log files.
  • Durable Touch Surface: High-durability analog resistive film touch screen rated for over 1 million physical operations.
  • Environmental Resilience: High protective construction rating safeguarding internal hardware against challenging industrial conditions.

Applications

  • Automotive assembly lines and conveyor control systems.
  • Packaging, labeling, and high-speed sorting machines.
  • Water treatment facilities and chemical processing plants.
  • Heating, ventilation, and industrial air conditioning (HVAC) systems.

Technical Specifications

Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number GT2308-VTBA
Series GOT2000 Series
Display Type TFT Color LCD
Screen Size 8.4 inches
Resolution 640 x 480 Dots (VGA)
Input Supply Voltage 100 to 240VAC (+10%, -15%)
Supply Frequency 50/60Hz (plus/minus 5%)
Max Power Consumption 11W or less (9W standalone, 6W backlight off)
Memory Capacity 9MB Flash ROM (Storage), 9MB RAM (Operation)
Inrush Current 40A or less (4ms duration at 25 degC ambient)
Battery Type GT11-50BAT Lithium Battery (approx. 5 years life)
Front Panel Protection IP67F
Rear Protection (Cabinet) IP2X
Dimensions (W x H x D) 241 x 194 x 56 mm
Panel Cutout Dimensions 227 x 176 mm
Net Weight 1.5 kg
Shipping Weight (Calculated) 2.2 kg

Connections and Interfaces

Interface Channel Connector Shape & Specification
Ethernet 1ch RJ-45 modular jack, 10BASE-T/100BASE-TX transfer speeds
RS-232 Serial 1ch D-sub 9-pin male connector (speeds up to 115,200 bps)
RS-422 / RS-485 Serial 1ch D-sub 9-pin female connector (speeds up to 115,200 bps)
USB Host 1ch USB Type-A port (Full-Speed 12 Mbps)
USB Device 1ch USB Mini-B port for PC communication/programming
SD Card Slot 1ch SDHC compliant slot (maximum 32GB)

Alternative Models & Compatibility

The GT2308-VTBA shares the identical 227 x 176 mm panel cutout dimensions of legacy models GT1665 and GT1565. This standardization allows for direct drop-in hardware replacement during control cabinet upgrades. When upgrading legacy applications, always use GT Works3 software to convert the source HMI project and update the PLC communication parameters to align with modern GOT2000 firmware dependencies.

Application Pitfalls & Engineering Notes

Do not install the HMI in configurations where it will be continuously exposed to direct sunlight or temperatures exceeding the operational limit of 55 degC, as thermal saturation will degrade LCD response times and shorten the life of the non-replaceable LED backlight. Ensure that high-frequency motor control lines or VFD power cabling are routed separately from the HMI serial communication cables to prevent electromagnetic noise induction on the RS-422/485 serial bus.

Commissioning & Wiring Tips

For reliable ground loop suppression, connect the HMI protective earth terminal to a dedicated ground system using 0.75 to 2 mm² wire. Secure all AC input connections to the terminal block using M3 ring terminals (such as RAV1.25-3) and torque the terminal screws precisely to 0.5 to 0.8 N·m. Always back up the active HMI project directly to an external SDHC card or through GT Works3 prior to firmware updates.

Installation Guidelines

CRITICAL WARNING:

Isolate and verify the de-energization of all power distribution blocks leading to the installation area before mounting or wiring the terminal. Contact with line voltage (100 to 240VAC) can cause catastrophic system failure, heavy electrical shock, or personal injury.

1
Verify the enclosure panel cutout parameters are prepared at exactly 227 mm wide by 176 mm high, with a maximum panel thickness of 5 mm.
2
Confirm that the waterproof packing/gasket is correctly seated in the mounting groove of the HMI unit to guarantee IP67F protection.
3
Slide the HMI into the cutout from the front of the panel and secure it using the supplied mounting brackets, tightening them to a torque range of 0.36 to 0.48 N·m.
4
Route power and communications lines. Apply 100-240VAC to the designated input terminals and execute initial display calibration.
Loading product navigation…

Can the GT2308-VTBA directly replace older GT1665 HMIs?

Yes, the GT2308-VTBA features identical panel cutout dimensions of 227 x 176 mm, allowing direct physical drop-in installation. Project graphics and parameters must be migrated using GT Works3.

What is the life expectancy of the LCD backlight on this terminal?

The built-in LED backlight is rated for approximately 50,000 hours of continuous operation at 25 degC before intensity drops to 50 percent. The backlight is not field-replaceable.

Is a battery required to maintain standard operations on the HMI?

The terminal utilizes a GT11-50BAT lithium battery to backup the real-time clock and retentive variables. The HMI will boot and run without a battery, but time-dependent functions and alarm logs will reset.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...