Operating as a central visualization bridge in modern control architectures, the Mitsubishi Electric GT2508-STBD graphic operation terminal delivers reliable performance for machine-level monitoring. This high-performance HMI features an 8.4-inch TFT color display with SVGA resolution (640 x 480 pixels), providing clear system diagnostics and process representation in space-constrained industrial panels. Engineered for integration with MELSEC PLCs and third-party controllers, it incorporates multi-touch capabilities to allow gestures such as pinching, zooming, and scrolling. The unit operates on standard 24 VDC power, features a black bezel, and hosts extensive connectivity interfaces, including Ethernet, serial, and USB ports to handle high-speed data transfers and logging.

Key Features

  • High-Contrast Display: 8.4-inch TFT color LCD screen rendering 65,536 colors at SVGA resolution.
  • Intelligent Multi-Touch: Supports dual-point touch commands for safe, multi-step operation and screen navigation.
  • Flexible Connectivity: Built-in Ethernet, RS-232, and RS-422/485 serial ports for diverse field communication.
  • Storage Expansion: Dedicated SD memory card slot and dual USB ports (Host and Device) for project management and diagnostics logging.
  • Robust Protection: Front panel rating conforms to IP67F standard protection against dust and water ingress when mounted.

Applications

  • Automotive assembly line work cells.
  • Water treatment processing and localized pumping stations.
  • Packaging, sorting, and material handling systems.
  • Chemical batching and food production control desks.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Identifier GT2508-STBD
Series GOT2000 / GT25
Display Size 8.4 Inches
Display Type TFT Color LCD
Resolution SVGA (640 x 480 pixels)
Backlight Unit LED (Non-replaceable, long-life)
Rated Input Voltage 24 VDC (+25%, -20%)
Frame Color Black
Memory Capacity User Memory: 32 MB
Panel Cutout Dimensions 227 mm x 176 mm
Operating Temperature Range 0 to 55 degC
Shipping Weight 8.0 kg (including secure packaging)

Connections and Interfaces

Interface Port Function / Connection Assignment
Ethernet Port 1x RJ45, 100BASE-TX/10BASE-T for PLC communication and network configuration
RS-232 Port 1x D-Sub 9-pin (Male) for legacy controller integration or barcode readers
RS-422/485 Port 1x D-Sub 9-pin (Female) for high-speed differential serial networks
USB Host Port 1x USB Type A (USB 2.0) for connecting external mice, keyboards, or storage
USB Device Port 1x USB Mini-B (USB 2.0) for project upload/download via local PC connection

Empirical Engineering Insights

Alternative Models & Compatibility

The GT2508-STBD serves as a standard form-factor replacement for legacy GOT1000 Series 8.4-inch units. When migrating from older installations, note that while the unit matches standard panel cutout profiles (227 mm x 176 mm), it has a slim-body design requiring less depth clearance inside the cabinet. Project conversion is managed seamlessly through MELSOFT GT Works3 software.

Application Pitfalls & Engineering Notes

When utilizing the logging and data backup functions, ensure that only industrial-grade SD cards are deployed. Standard consumer-grade SD cards face rapid write-cycle exhaustion under continuous parameter logging regimes, which can lead to file system corruption and system lockups. Ensure at least 100 mm of physical clearance at the rear and top of the unit for unrestricted cooling airflow.

Commissioning & Wiring Tips

For reliable performance in high-noise environments, the frame ground (FG) terminal must be wired directly to a dedicated Class D electrical ground with a resistance of 100 ohms or less. Avoid running the 24 VDC power lines in the same wire duct as high-voltage AC motor lines or VFD outputs to prevent electrical noise coupling into the sensitive logic boards.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary power systems before initiating any panel cutting or physical installation. Confirm that the input supply matches the required 24 VDC standard. Operating outside the designated voltage tolerance (19.2 to 28.8 VDC) risks catastrophic damage to the terminal's internal components.
1 Prepare a clean cutout measuring 227 mm x 176 mm. Ensure the panel thickness is within 2.0 mm and 4.0 mm to guarantee physical stability.
2 Check that the environmental sealing gasket is fully seated and free of debris in its rear bezel groove before inserting the terminal into the panel.
3 Insert the supplied mounting clamps into the terminal side-recesses and tighten the screws evenly to a target torque of 0.36 to 0.48 N-m to achieve a complete IP67F seal without distorting the frame.
4 Connect the communication cables to their dedicated ports, ensuring secure physical connections to prevent vibration-induced disconnects during operation.
Loading product navigation…

What configuration software is required for the GT2508-STBD HMI?

Screen design and project setup must be configured using MELSOFT GT Works3 (GT Designer3 version 1.155B or later).

Does this model support projects built for legacy GOT1000 HMIs?

Yes. GT Designer3 includes a dedicated migration utility to automatically convert legacy projects for installation on GOT2000 hardware.

What is the acceptable supply voltage range for the terminal?

The unit operates on a nominal 24 VDC power supply with an allowable operational tolerance range of 19.2 VDC to 28.8 VDC.

How do you achieve the specified IP67F protection rating?

The terminal must be installed using the supplied mounting clamps, tightened to a uniform torque between 0.36 and 0.48 N-m, with the continuous gasket fully seated.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...