1 de 1

Mitsubishi Electric GT2708-VTBD GOT2000 Series Graphic Operation Terminal

Mitsubishi Electric GT2708-VTBD GOT2000 Series Graphic Operation Terminal

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Mitsubishi Electric

  • Nº do Produto: GT2708-VTBD

  • País de origem:Estados Unidos

  • Tipo de Produto: Human-Machine Interfaces

  • Pagamento: T/T, Western Union

  • Peso: 1500g

  • Dimensões: 241 mm x 194 mm x 52 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Engineered for high-resolution industrial visualization, the GT2708-VTBD is an 8.4-inch TFT color human-machine interface (HMI) within the high-performance GOT2000 Series. This terminal acts as a central control and monitoring hub, enabling seamless interaction between operators and automation systems. Equipped with a VGA display, it provides crisp graphical readouts of complex processes, machinery status, and diagnostic alarms.

The unit features an active-matrix TFT LCD designed for reliability in harsh industrial environments. Its self-cooling design and extensive terminal connectivity allow it to integrate cleanly into standard electrical control panels. Ideal for interfacing with programmable logic controllers (PLCs), motion controllers, and variable frequency drives, the terminal ensures stable operation under varying mechanical and electrical demands.

Features

  • High-clarity 8.4-inch TFT color screen supporting VGA (640 x 480) resolution.
  • Flexible layout configurations accommodating both horizontal and vertical mounting orientations.
  • Low-power standalone mode that reduces consumption to 8 W when the backlight is disabled.
  • Robust physical architecture compliant with international standards for mechanical shock and vibration.
  • Self-cooling system requiring no active fan components, minimizing dust intake.

Applications

  • Automotive assembly and robotic integration cells.
  • Water and wastewater treatment plant control stations.
  • Packaging, food, and beverage processing lines.
  • Power generation and auxiliary process monitoring.

Technical Specifications

ManufacturerPart Number / ModelSeriesDisplay SizeDisplay TypeResolutionFrame ColorInput Power Supply VoltageMaximum Power ConsumptionPower Consumption (Standalone)Power Consumption (Backlight Off)Inrush CurrentOperating Ambient Temperature (Horizontal)Operating Ambient Temperature (Vertical)Storage Ambient TemperatureOperating/Storage HumidityImpact ResistanceInsulation ResistanceWithstand VoltageCooling MethodExternal Dimensions (W x H x D)Weight
Mitsubishi Electric
GT2708-VTBD
GOT2000 Series (GT27)
8.4 inches
TFT Color LCD
VGA (640 x 480 pixels)
Black
24VDC (+25%, -20%)
39 W or less
13 W
8 W
5A or less (for 20 ms at 25 degC, max load)
0 to 55 degC
0 to 50 degC
-20 to 60 degC
10 to 90% RH (non-condensing)
Conforms to JIS B 3502 and IEC 61131-2 (147 m/s2 [15G], 3 times in X, Y, and Z axes)
10 MOhm or higher via 500VDC insulation tester (between power terminal and ground)
350VAC for 1 minute (between power terminal and ground)
Self-cooling
241 mm x 194 mm x 52 mm
1.5 kg (excluding mounting brackets)

Connections and Interfaces

Applicable Wire SizeTerminal Screw TypeTightening TorqueCompatible Solderless Terminals
Interface/Terminal Component Specification / Type
0.75 to 2 mm2
M3 Screw Clamp Terminals
0.5 to 0.8 N.m
RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A

Installation Guidelines

  • Mount the terminal inside a sealed electrical control enclosure to safeguard against greasy fumes, corrosive gases, and conductive dust.
  • Ensure adequate surrounding clearance to maintain clear self-cooling airflow paths.
  • Verify that the operating angle does not exceed thermal limitations (derate maximum operating temperature to 50 degC if mounted vertically).
  • Ground the terminal using the designated ground point with a dedicated Class D ground connection (100 ohms or less) to minimize electromagnetic interference.

Compliance and Certifications

  • IEC 61131-2 (Industrial-process control instruments - Specifications and tests)
  • JIS B 3502 (Japanese Industrial Standards for Programmable Controllers)
Loading product navigation…

What is the acceptable input voltage range for the GT2708-VTBD?

The terminal is rated for 24VDC with an acceptable input voltage tolerance of +25% to -20% (19.2VDC to 30VDC).

Does the HMI support vertical installation, and are there environmental restrictions?

Yes, vertical installation is supported. However, the maximum allowable operating ambient temperature is derated to 50 degC compared to 55 degC for horizontal installation.

What size and type of wire is required for the power terminal block?

The terminal block accepts wire sizes ranging from 0.75 to 2 mm2, utilizing M3 clamp screws with a recommended tightening torque of 0.5 to 0.8 N.m.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...