1 из 1

Delta Electronics DOP-112MX DOP-100 Series Advanced Multimedia HMI

Delta Electronics DOP-112MX DOP-100 Series Advanced Multimedia HMI

Остался в наличии только 10 товар(ы)
  • Производитель: Delta Electronics

  • Номер продукта: DOP-112MX

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: HMI Panels

  • Оплата: Т/Т, Western Union

  • Вес: 3000г

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Designed to serve as a high-performance operator control center, the Delta Electronics DOP-112MX integrates sophisticated visualization and multimedia capabilities within demanding industrial environments. This 12.1-inch DOP-100 Series human-machine interface offers a high-resolution XGA display combined with advanced connectivity options to optimize machine monitoring, real-time data logging, and interactive process management.

Equipped with a fast ARM Cortex-A8 processor, the unit handles heavy graphic rendering and simultaneous serial and Ethernet communication tasks without latency. The advanced multimedia type designation signifies its onboard video input capabilities, audio output interface, and extended flash memory storage, making it suitable for security monitoring, visual inspection feedback, and interactive training prompts directly on the factory floor.

Key Features

  • High-definition 12.1-inch XGA TFT display offering 65,536 colors for crisp visualization of detailed piping and instrumentation diagrams (P&IDs).
  • Advanced multimedia configuration featuring direct analog video input interface and stereo audio output.
  • Dual integrated Ethernet ports (LAN1 and LAN2) enabling secure logical network separation between field control networks and enterprise systems.
  • Rugged IP65 / NEMA 4 rated front panel construction protecting sensitive inner electronics from water jets and fine particulate ingress.
  • Onboard multi-com ports supporting RS-232, RS-422, and RS-485 interfaces for simultaneous multi-protocol PLC connectivity.

Applications

  • Water & Wastewater Treatment: Centralized visualization of pumping arrays, chemical dosing systems, and remote telemetry terminal units.
  • Packaging & Material Handling: Local machine control interfaces requiring real-time diagnostic video feeds and high-speed communications.
  • Automotive Assembly Lines: Integration of process cameras via analog input for live panel inspection and local operator validation.
  • HVAC Control Systems: Management of large-scale building management systems with extensive Modbus-RTU and BACnet networking.

Technical Specifications

Parameter Specification Value
Manufacturer Delta Electronics
Model Number DOP-112MX
Product Series DOP-100 Series
Display Size & Type 12.1 inch TFT LCD (65,536 colors)
Resolution XGA (1024 x 768 pixels)
Processor (MCU) ARM Cortex-A8 (800MHz)
Memory Flash ROM 8 GB
System RAM 1 GB
Power Input DC +24V (allowable range DC +19.2V to DC +28.8V)
Power Consumption 14W (typical)
Operating Temperature 0 to 50 degC
Storage Temperature -20 to 60 degC
Front Protection Degree IP65 / NEMA 4 (Indoor use only)
Net Weight 2,110 g
Shipping Weight (Calculated) 3.0 kg
Panel Cutout Dimensions 302 mm x 228 mm

Connections and Interfaces

Port / Interface Signal / Circuit Pin Assignment
COM1 RS-232 (Supports hardware flow control RXD, TXD, RTS, CTS, GND)
COM2 RS-485 / RS-422 (D+, D- Differential Pair / TXD+, TXD-, RXD+, RXD-)
COM3 RS-422 / RS-485 (Configurable via internal system software)
LAN1 RJ-45 Ethernet port (10/100 Mbps, Auto MDI/MDI-X)
LAN2 RJ-45 Ethernet port (10/100 Mbps, isolated network node capability)
USB Host USB Type-A Host (Ver 2.0 for flash drives, barcode scanners, and mice)
USB Client USB Mini-B Client (Ver 2.0 for firmware programming and software downloads)
Audio / Video In Stereo Audio Line Out / Analog CVBS camera input interface

Empirical Engineering Insights

Alternative Models & Compatibility

The DOP-112MX is a drop-in replacement for legacy DOP-B series 10-inch and 12-inch units. However, ensure to verify the physical cabinet cutout dimensions, as legacy models may have differed slightly. Project conversion from older DOPSoft v2 files to DOPSoft v4 requires checking screen layout aspect ratio mapping, as the DOP-112MX runs at XGA (1024 x 768) resolution, which might stretch assets designed for SVGA formats.

Application Pitfalls & Engineering Notes

When utilizing both LAN1 and LAN2 ports, do not assign IP addresses in the identical subnet. Doing so will cause routing tables within the Linux-based operating system of the HMI to crash or drop network packets selectively. Always maintain physical and logical segregation (e.g., LAN1 on 192.168.1.XX for the control network and LAN2 on 10.10.1.XX for database/SCADA reporting).

Commissioning & Wiring Tips

For electrical noise resilience, ground the HMI chassis through the designated functional ground terminal using a 16 AWG or thicker wire to a single-point industrial earth ground. Ensure that the RS-485 serial cables are shielded, and termination resistors (120 Ohm) are switched in place on the last physical node of the network chain to prevent message packet drops.

Installation Guidelines

CRITICAL WARNING: Verify that the incoming supply line is fully de-energized and locked out before connecting the 24V DC terminal block. Connecting electrical power while live can arc-damage the terminal connectors and compromise integrated circuitry. Do not exceed 28.8V DC power input.
1
Verify the panel cutout meets the exact dimensions of 302 mm x 228 mm with an allowable cabinet plate thickness between 1.6 mm and 6.0 mm.
2
Ensure the integrated waterproof gasket is seated correctly and flush within the front bezel recess before pushing the HMI into the cutout panel.
3
Tighten the standard mounting brackets evenly around the perimeter of the panel to a torque specification of 0.5 to 0.7 N-m to achieve IP65 sealing. Do not overtighten, as this may warp the plastic bezel.
4
Connect the dedicated functional ground (FG) terminal, insert the communications cabling, and lastly plug in the wired 24V DC terminal connector block.
Loading product navigation…

Which programming software is required for configuring the Delta DOP-112MX HMI?

Configuration requires Delta DOPSoft software (Version 4.00 or higher). Communication, graphics, and script actions are compiled in DOPSoft and downloaded to the panel via a Mini-B USB interface or Ethernet.

How are the two Ethernet ports configured on the DOP-112MX?

The ports operate on independent network modules. To ensure proper packet delivery, configure them on separate IP subnets (e.g., LAN1 for local PLC communication, LAN2 for WAN or corporate SCADA connection).

Does this advanced multimedia model support direct camera feeds?

Yes. The DOP-112MX includes built-in analog video inputs that accept standard PAL or NTSC CVBS signals, enabling live-camera viewing on the HMI screen.

Can I back up recipes and event history logs to an external storage device?

Yes, logs and files can be stored locally on the unit's 8 GB internal flash memory or routed directly to external storage via the integrated USB Host 2.0 interface or via network transfer protocols.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом на верёвке до аккумуляторных шахтных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как...