1 จาก 1

Mitsubishi Electric FR-A820-0.75k FREQROL-A800 High Performance Inverter

Mitsubishi Electric FR-A820-0.75k FREQROL-A800 High Performance Inverter

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A820-0.75k

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Engineered to meet the demands of highly dynamic industrial motor applications, the Mitsubishi Electric FR-A820-0.75k is a premium FREQROL-A800 series variable frequency drive designed for high-precision speed and torque control. This drive accommodates multiple operating duties, including Normal Duty (ND) at 0.75 kW, Heavy Duty (HD) at 0.4 kW, and Light/Super Light Duty (LD/SLD) up to 1.5 kW, allowing electrical engineers to configure a single physical chassis for varying load profiles. By integrating advanced motor control algorithms like real sensorless vector control and PM sensorless vector control, the FR-A820-0.75k maintains stable performance and high starting torque across a broad frequency spectrum of 0.2 to 590 Hz.

Features

  • Multi-Duty Capability: Selectable SLD, LD, ND, and HD ratings to adapt to variable torque, constant torque, and high-overload profiles.
  • Advanced Control Algorithms: Selectable V/F control, advanced magnetic flux vector control, real sensorless vector control, and PM sensorless vector control.
  • Robust Overload Margins: Up to 200% for 3 seconds and 150% for 60 seconds under default Normal Duty (ND) configurations.
  • Integrated Safety Function: Features built-in safety stop capabilities conforming to international functional safety standards.
  • High-Speed Communications: Built-in RS-485 interface with native support for Modbus RTU, CC-Link, and common industrial fieldbuses.

Applications

  • Conveyor and Material Handling Systems: Providing smooth acceleration ramps and precise multi-stage speed profiles.
  • Machine Tool Spindles: Requiring stable high-speed performance and rapid, controlled braking cycles.
  • Centrifugal Pumps and Fans: Utilizing optimum excitation control to maximize energy efficiency under variable torque loads.
  • Packaging and Textile Machinery: Delivering consistent torque and tension control at low operational speeds.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Number FR-A820-0.75k
Series Name FREQROL-A800
Power Supply Voltage 3-Phase 200 to 240 VAC, 50 Hz / 60 Hz
Allowable Voltage Fluctuation 170 to 264 VAC
Motor Capacity (ND / Default) 0.75 kW
Motor Capacity (HD / High Duty) 0.4 kW
Motor Capacity (LD / SLD) 1.5 kW
Rated Output Current (ND) 5.0 A
Output Frequency Range 0.2 to 590 Hz (Vector/Sensorless limits to 400 Hz)
Cooling Method Self-cooling
Protective Rating IP20 (Closed Type)
Ambient Operating Temperature -10 to +50 degC (LD, ND, HD ratings, non-freezing)
Ambient Storage Temperature -20 to +65 degC
Net Weight 2.2 kg
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

Terminal / Port Function Assignment
Terminals 2, 4 Analog input: 0 to 10 V, 0 to 5 V, or 4 to 20 mA (selectable)
Terminal 1 Auxiliary analog input: -10 to +10 V or -5 to +5 V
Digital Inputs (12 Points) Configurable control signals (Start, Forward/Reverse, Jog, Reset, Speed Selection)
Open Collector Outputs (5 Points) Configurable status signals (Run, Up-to-speed, Overload Alarm)
Relay Outputs (2 Points) Fault and high-current alarm configuration
RJ-45 Connector RS-485 Modbus RTU interface / Parameter unit connection

Alternative Models & Compatibility

The FR-A820-0.75k directly replaces older generation FR-A720-0.75K inverters. While basic terminal block signals are layout-compatible, always review software and parameter sets using FR Configurator2 to ensure custom terminal logic mappings transition smoothly without triggering internal interlocking conflicts.

Application Pitfalls & Engineering Notes

When sizing this VFD for high starting torque loads in Heavy Duty (HD) mode, remember the maximum motor capacity is reduced to 0.4 kW. Attempting to run a 0.75 kW motor under high-vibration, high-duty cycles on the HD parameter mapping will cause rapid thermal accumulation and lead to E.THT (Inverter Overload) faults. Ensure proper clearance of at least 50 mm above and below the self-cooling frame inside sealed enclosures to avoid heat trapping.

Commissioning & Wiring Tips

For setups utilizing Real Sensorless Vector Control or PM Sensorless Vector Control, performing an offline auto-tuning sequence (Parameter 96) is highly critical. Tuning must be executed with the motor uncoupled from the gearbox or mechanical load to prevent incorrect stator resistance and inductance readings, which are the root cause of E.OC1 (Overcurrent during acceleration) errors at low speeds.

Installation Guidelines

CRITICAL WARNING: Before starting installation or maintenance, isolate all primary three-phase power supplies. Wait at least 10 minutes for the internal DC bus capacitors to discharge fully. Verify zero-voltage potential on the charge indicator LED and across terminals P/+ and N/- using a calibrated multimeter before touching internal terminals.
1
Mount the drive vertically on a flat, non-flammable surface inside a dust-free enclosure using the specified mounting screws to secure the chassis.
2
Route incoming three-phase AC mains power lines to terminal lugs R/L1, S/L2, and T/L3. Never connect mains utility voltage to the motor output terminals U, V, and W.
3
Verify that all ground connections are terminated securely using a dedicated earth terminal. Use shielded control cables for all analog and digital reference wiring to prevent electromagnetic noise interference.

What are the output capacity differences between ND and HD duty cycles on this VFD?

Under Normal Duty (ND), the drive is rated for 0.75 kW motors with a 5.0 A continuous output. Under Heavy Duty (HD), the allowable motor capacity decreases to 0.4 kW, providing a tighter current limit but yielding higher instantaneous overload torque percentages.

Does this drive support permanent magnet motor vector control?

Yes, the FR-A820-0.75k natively supports PM sensorless vector control, allowing open-loop speed and torque regulation of PM motors up to a frequency of 400 Hz.

What is the function of the external 24 VDC control power input?

Connecting an external 24 VDC supply keeps the drive's control circuitry, network communication modules, and diagnostic parameters online even when the primary 3-phase mains distribution lines are completely isolated.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...