1 จาก 1

Mitsubishi Electric Q02UCPU MELSEC Q Series PLC CPU Module

Mitsubishi Electric Q02UCPU MELSEC Q Series PLC CPU Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: Q02UCPU

  • Country of origin:สหรัฐอเมริกา

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 120 mm x 110 mm x 40 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Engineered for high-speed sequence control within demanding industrial environments, the Mitsubishi Electric Q02UCPU serves as a highly reliable central processing unit for the MELSEC Q Series automation platform. This Universal Model CPU delivers optimized instruction execution speeds and expanded memory capacity to handle complex automation tasks, making it a cornerstone for modular control architectures.

Key Features

  • High-Speed Processing: Achieves a basic instruction execution speed of 40 nanoseconds (LD instruction), minimizing scan cycle times.
  • Expanded Memory: Features a 20k-step (80 KB) program capacity alongside dedicated multi-port memory structures.
  • Dual Communication Ports: Equipped with built-in USB (Mini-B) and RS-232 interfaces for direct programming, diagnostics, and peripheral interfacing.
  • Scalable I/O Architecture: Supports up to 2048 local I/O points and up to 8192 remote I/O points across network links.
  • Multi-CPU Support: Compatible with multi-CPU configurations, allowing up to four CPUs to reside on a single Q-series base unit for distributed processing.

Industrial Applications

  • Automotive assembly lines and robotic cell synchronization.
  • High-speed packaging, filling, and labeling machinery.
  • Water treatment facilities and distributed pump station control.
  • Semiconductor fabrication tool handling and cleanroom automation.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Q02UCPU
Series MELSEC-Q Series (Universal Model)
Program Capacity 20k steps (80 KB)
LD Instruction Speed 40 ns (0.04 microseconds)
Local I/O Points 2048 points
Total I/O Points (Local + Remote) 8192 points
Internal Current Consumption (5 VDC) 0.33 A
Communication Interfaces USB (Mini-B), RS-232 (6-pin Mini-DIN)
Memory Type Flash ROM, SRAM (via optional memory card)
Mounting Type Base unit rack mount
Country of Origin Japan
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 120 mm x 110 mm x 40 mm

Connections and Interfaces

Connector / Port Interface Type Function / Assignment
USB Port Mini-B Female High-speed programming, monitoring, and diagnostics via GX Works2 / GX Developer.
RS-232 Port 6-pin Mini-DIN Serial connection for HMIs, legacy programming tools, or point-to-point serial communication protocols.

Empirical Engineering Insights

Alternative Models & Compatibility

The Q02UCPU is part of the "Universal" Q-series lineup, which directly replaces older "Basic" and "High-Performance" CPUs such as the Q02CPU. Note that Universal models require a compatible Universal-ready base unit (e.g., Q33B-E, Q38DB) to utilize advanced features and high-speed bus communication. Ensure your programming software is updated to GX Works2 or GX Developer Version 8.76D or later to support the Universal instruction set.

Application Pitfalls & Engineering Notes

When designing multi-CPU systems, calculate the total 5 VDC current draw. The Q02UCPU draws 0.33 A internally. If paired with high-density I/O modules or multiple coprocessor modules, verify that the system power supply module (e.g., Q61P or Q62P) has sufficient overhead to prevent voltage drops during peak processing cycles.

Commissioning & Wiring Tips

When utilizing the RS-232 serial interface in electrically noisy environments (near VFDs or high-power contactors), always use double-shielded serial cabling. Ground the cable shield at the PLC chassis ground terminal only to prevent ground loops that can corrupt serial data packets.

Installation Guidelines

CRITICAL WARNING

Always completely de-energize the main power supply to the base unit before inserting or removing the CPU module. Hot-swapping the CPU can cause permanent damage to the internal ASIC chips, corrupt the system memory, or cause unpredictable machinery behavior.

1

Ensure the base unit is securely mounted to the DIN rail or control panel backplate and grounded correctly.

2

Insert the lower module fixing projection of the Q02UCPU into the module guide hole of the base unit.

3

Push the top of the module firmly against the base unit until it is fully seated in the connector.

4

Tighten the module fixing screw to a torque of 0.36 to 0.48 N·m to ensure mechanical stability and proper grounding.

What software is required to program the Q02UCPU?

The module is programmed using Mitsubishi Electric's GX Works2 or GX Developer (Version 8.76D or later). Connection is established via the built-in Mini-USB or RS-232 ports.

Does the Q02UCPU have an integrated Ethernet port?

No, the Q02UCPU does not feature a built-in Ethernet port. It relies on USB and RS-232 for direct communications. For built-in Ethernet, consider models like the Q02UDVCPU or Q03UDECPU.

What is the internal current consumption of this CPU module?

The Q02UCPU draws 0.33 A from the 5 VDC internal bus supplied by the base unit power supply module.

Can I use older Q-series base units with this Universal CPU?

Universal CPUs require compatible base units (such as the Q3_DB or Q3_B series) to utilize high-speed communication paths. Check your base unit part number for compatibility before installation.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...