Description

This is a Siemens 6ES7138-4FA03-0AB0 fail-safe digital input module for the SIMATIC ET 200S distributed I/O system. It is engineered to acquire safety-related signals from field devices, providing 4 or 8 configurable channels of 24V DC inputs that communicate via the PROFIsafe protocol. The module is certified to meet high safety standards, including SIL 3 (IEC 62061) and PL e (ISO 13849), making it suitable for critical safety functions. Its compact 30mm form factor optimizes cabinet space while offering flexible integration into both PROFIBUS DP and PROFINET networks when used with compatible interface modules.

Features

  • Configurable for 4 or 8 fail-safe digital input channels.
  • Supports the PROFIsafe protocol for secure data transmission.
  • Certified for Category 4 (EN 954-1), SIL 3 (IEC 62061), and PL e (ISO 13849).
  • Compatible with both PROFIBUS DP and PROFINET networks.
  • Features optical isolation for signal integrity.
  • Includes comprehensive diagnostic capabilities.
  • Compact 30mm width for high-density installations.

Applications

  • Emergency stop circuits
  • Safety gate and light curtain monitoring
  • Automotive manufacturing lines
  • Packaging and material handling machinery
  • Distributed safety systems requiring high integrity levels

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6ES7138-4FA03-0AB0
Product Series SIMATIC ET 200S
Module Type Fail-Safe Digital Input Module
Number of Inputs 4 or 8, configurable
Input Voltage 24V DC
Safety Communication PROFIsafe
Supported Networks PROFIBUS DP, PROFINET
Safety Integrity Level SIL 3 according to IEC 62061
Performance Level PL e according to ISO 13849-1
Safety Category Category 4 according to EN 954-1
Module Width 30 mm
Shipping Weight 0.24 kg
Package Dimensions (Calculated) 10.5 x 12.5 x 4 cm
Country of Origin Germany

Installation Guidelines

CRITICAL WARNING: Installation, commissioning, and maintenance of this safety-rated module must be performed by qualified personnel with expertise in functional safety standards (e.g., IEC 61508, ISO 13849). Failure to correctly install, configure, and validate the safety function can result in serious injury or death.
  1. 1
    De-energize System: Before installation, disconnect and lock out all power sources to the control panel and the ET 200S station according to established Lockout/Tagout (LOTO) procedures. Verify that all circuits are de-energized.
  2. 2
    Mount Terminal Module: Securely mount the appropriate ET 200S terminal module (e.g., TM-E30) onto the DIN rail. Ensure a solid mechanical and electrical connection to the rail for proper grounding.
  3. 3
    Install Electronic Module: Align the 6ES7138-4FA03-0AB0 electronic module with the terminal module and firmly press it into place until it audibly clicks, ensuring it is fully seated and engaged with the backplane bus connectors.
  4. 4
    Connect Sensor Wiring: Terminate the wiring from safety sensors (e.g., E-stops, gate switches) to the designated terminals on the terminal module. Use shielded, twisted-pair cabling for all safety circuits and ensure shields are properly grounded at one end to minimize noise interference.
  5. 5
    Commission and Validate: After restoring power, use the engineering software to configure the module's PROFIsafe address and parameters. Perform a comprehensive functional test of every safety input to validate that the system behaves as designed and meets the required safety performance level.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...