1 จาก 1

Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232/485 Modbus TCP/RTU Gateway

Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232/485 Modbus TCP/RTU Gateway

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: IE-GWT-MB-2TX-1RS232/485

  • Country of origin:เยอรมนี

  • Product Type: Modbus Gateways

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Dimensions: 29 mm x 124.5 mm x 89.2 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Facilitating seamless protocol translation between serial Modbus RTU/ASCII and Ethernet-based Modbus TCP networks, the Weidmuller 1504470000 (model IE-GWT-MB-2TX-1RS232/485) serves as an industrial-grade communication gateway designed for high-reliability automation environments. This device bridges legacy serial field devices with modern Ethernet control architectures, ensuring low-latency data transmission and robust network integration.

Key Features

  • Dual Ethernet ports (2TX) allowing for daisy-chain network topologies and simplified cabling.
  • Software-selectable serial interface supporting RS-232, RS-422, and RS-485 configurations.
  • Redundant 24 V DC power inputs to maximize system uptime and operational resilience.
  • Integrated Serial Redirection and Priority Control for optimized traffic management.
  • Compact, space-saving IP30 plastic housing designed for standard DIN rail mounting.

Applications

  • Substation automation and power monitoring network integration.
  • Connecting legacy serial PLCs and RTUs to modern SCADA host systems.
  • Water and wastewater treatment facility remote telemetry.
  • Factory automation and machine-to-machine (M2M) communication bridging.

Technical Specifications

Parameter Value
Manufacturer Weidmuller
Article Number (SKU) 1504470000
Model Designation IE-GWT-MB-2TX-1RS232/485
Ethernet Ports 2x RJ45 (10/100BaseT(X))
Serial Ports 1x RS-232/425/485 (DB9 male or terminal block options)
Supply Voltage 24 V DC (Redundant inputs)
Connector Type 1 removable 7-pole terminal block
Operating Temperature -40 to 75 degC
Storage Temperature -40 to 85 degC
Ambient Relative Humidity 5% to 95% (non-condensing)
Protection Class IP30
Housing Material Plastic
Mounting Type DIN rail
Dimensions (W x H x D) 29 mm x 124.5 mm x 89.2 mm
Net Weight 190 g
Shipping Weight (Calculated) 1.0 kg

Connections and Interfaces

Interface / Terminal Functional Assignment
7-Pole Terminal Block Redundant Power Input 1 (V1+, V1-), Redundant Power Input 2 (V2+, V2-), Functional Earth (FE)
RJ45 Ports (1 & 2) 10/100BaseT(X) Ethernet interfaces with auto MDI/MDI-X crossover detection
Serial Port RS-232 (TxD, RxD, GND) / RS-485 (Data+, Data-, GND) software-configurable pins

Empirical Engineering Insights

Alternative Models & Compatibility

The IE-GWT-MB-2TX-1RS232/485 is backward compatible with standard Modbus RTU devices operating over RS-485 2-wire networks. When replacing older single-port serial servers, the dual Ethernet ports on this model eliminate the need for an external switch in simple line topologies, reducing overall panel hardware costs.

Application Pitfalls & Engineering Notes

In high-density electrical cabinets, ensure adequate clearance around the IP30 plastic housing to maintain natural convection cooling. While rated up to 75 degC, operating continuously at extreme temperatures without proper ventilation can accelerate component aging. Always verify that the Modbus TCP client timeout settings are configured to accommodate the serial bus latency, especially when polling multiple daisy-chained RTU slaves.

Commissioning & Wiring Tips

When wiring the RS-485 network, always install a 120-ohm termination resistor at both physical ends of the communication line to prevent signal reflections. Ensure the Functional Earth (FE) terminal on the 7-pole block is connected directly to a low-impedance ground plane to safeguard the internal transceiver circuits from transient voltage spikes and electromagnetic interference.

Installation Guidelines

CRITICAL WARNING

Disconnect all power sources before attempting installation, wiring, or removal of the gateway. Failure to de-energize the system can result in electrical shock, equipment damage, or unexpected control system behavior.

1

Mount the gateway onto a standard TS 35 DIN rail, ensuring the locking mechanism snaps firmly into place.

2

Connect the Functional Earth (FE) terminal to the local ground system to ensure proper noise immunity.

3

Wire the redundant 24 V DC power supplies to the removable 7-pole terminal block, verifying correct polarity before energizing.

4

Connect the RJ45 Ethernet cables and the serial interface lines, securing all physical connections.

What is the purpose of the dual Ethernet ports on the Weidmuller 1504470000?

The dual RJ45 ports (2TX) allow for daisy-chaining multiple Ethernet devices in a line topology, reducing the need for external network switches and simplifying field wiring.

Does this gateway support redundant power inputs?

Yes, the device features redundant 24 V DC power inputs via a removable 7-pole terminal block to ensure continuous operation if one power source fails.

How do I configure the serial port for RS-485 or RS-232?

The serial interface configuration (RS-232, RS-422, or RS-485) is software-selectable through the gateway's web-based management utility or configuration software.

What is the operating temperature range of the IE-GWT-MB-2TX-1RS232/485?

The gateway is designed for harsh environments, supporting an operating temperature range of -40 to 75 degC.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...