1 จาก 1

X20SO4120 B&R X20 Series 4-Channel High-Current Safe Output Module

X20SO4120 B&R X20 Series 4-Channel High-Current Safe Output Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20SO4120

  • Country of origin:สหรัฐอเมริกา

  • Product Type: X20 Safe Output Module

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The X20SO4120 (X20SO4120) is a high-performance, intelligent safety output module designed for the B&R X20 system. Engineered to meet the most stringent safety requirements (up to SIL 3 / PLe), this module features 4 safe digital Type A outputs, each capable of delivering up to 2 A of current. This high-current capacity makes the X20SO4120 ideal for directly driving larger safety actuators, heavy-duty contactors, and hydraulic valves without the need for interposing relays. With integrated OSSD (Output Signal Switching Device) functionality and a diagnostic pulse width of less than 500 microseconds, the module ensures continuous monitoring for short circuits and cross-faults, maintaining maximum safety integrity in high-speed automated environments such as metal forming, robotic cells, and heavy material handling.

Technical Configuration

The hardware of the X20SO4120 is built for transparency and resilience. It features individual current monitoring for each channel, allowing the Safety CPU to detect "stuck-at" faults or load anomalies in real-time. The module identifies itself in the system via the B&R ID code 0x2007 and provides comprehensive visual diagnostics through LEDs indicating I/O function per channel, operating state, and general module status. Power management is highly efficient, with a bus consumption of just 0.25 W, while the internal I/O circuitry draws 1.3 W. By utilizing the openSAFETY protocol, the X20SO4120 provides a seamless, deterministic safety loop that minimizes the time between a fault detection and the transition to a Safe State.

Technical Specifications

Feature Specification Details
Model X20SO4120
Brand B&R Industrial Automation
B&R ID Code 0x2007
Module Type Safe Digital Output (Type A)
Number of Outputs 4
Nominal Voltage 24 VDC
Output Current 2.0 A per channel
OSSD Pulse Width Less than 500 microseconds
Current Monitoring Integrated (Per channel)
Power Consumption (Bus) 0.25 W
Power Consumption (I/O) 1.3 W
Safety Certification SIL 3, PLe
Protection Rating IP20
Shipping Weight 1.5 kg

Technical FAQs

How does the 2 A rating of the X20SO4120 compare to the X20SO4110?

The X20SO4120 provides a significantly higher output capacity (2 A per channel) compared to the X20SO4110 (0.5 A). This allows the 4120 variant to drive high-power inductive loads like large DC brakes or pneumatic manifolds directly, which would otherwise exceed the current limits of standard safe output modules.

What diagnostics are available via the status indicators?

The module features LEDs for "Operating State" and "Module Status," which indicate if the module is in safe-run mode, pre-operational mode, or a fail-safe state. Additionally, individual "I/O function" LEDs light up when an output is energized, and flash patterns can indicate specific faults like short circuits or overcurrent.

Is the OSSD pulse width adjustable?

The <500 microsecond pulse width is a fixed hardware characteristic designed to ensure that the "off-test" is too fast for the mechanical contacts of a relay or valve to respond, thus preventing chattering while maintaining a high diagnostic coverage.


Engineering & Installation Guide

  • Total Current Calculations: With a 2 A capacity per channel, a fully loaded module can draw up to 8 A. It is critical to ensure that the X20 power supply module (e.g., X20PS) feeding this segment is rated for the cumulative peak current and that the supply wiring is of sufficient gauge to prevent voltage drops during simultaneous switching.

  • Inductive Load Protection: When controlling large inductive loads, the back-EMF can be substantial. Although the X20SO4120 has internal protection, adding an external recovery diode or varistor at the load side is recommended for 2 A applications to reduce electromagnetic noise and thermal stress on the module’s transistors.

  • Safe Wiring separation: To maintain the SIL 3 rating, keep the safe output wiring physically separated from high-voltage AC cables. Use shielded cables for the 24 VDC lines if they run parallel to motor cables for long distances to prevent induced voltages from interfering with the OSSD pulse detection logic.

 

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีเหลือง
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...