1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff CX8010 Embedded PC with EtherCAT Slave

Beckhoff CX8010 Embedded PC with EtherCAT Slave

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: CX8010

  • Menşei ülke:Almanya

  • Ürün Türü: Embedded PCs

  • Ödeme: T/T, Western Union

  • Ağırlık: 500g

  • Boyutlar: 64 mm x 100 mm x 73 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Directing decentralized execution tasks within real-time automation topologies is the primary function of the Beckhoff CX8010. This compact, DIN-rail-mounted control unit integrates an ARM9 400 MHz processor with a specialized EtherCAT slave interface, permitting seamless integration as a high-performance decentralized node under a primary EtherCAT master. Operating on the Windows Embedded CE 6 operating system, the controller uses the TwinCAT 2 PLC software environment to execute deterministic control loops, processing local logic while maintaining cyclic communication over its physical interfaces. Built-in, automatic terminal detection accommodates either E-bus or K-bus I/O architectures, allowing engineers to scale localized signal acquisition without external adapter hardware.

Key Features

  • Dual Bus Support: Automatic sensing and management of Beckhoff E-bus (EtherCAT) and K-bus (standard bus terminal) components.
  • Integrated UPS: Capable of supplying power for 1 second to write up to 1 MB of persistent data to the non-volatile storage during a voltage sag.
  • Deterministic Processing: ARM9 core design running at 400 MHz optimized for low-overhead PLC logic execution under IEC 61131-3 standards.
  • Flexible Storage Options: External microSD slot supporting memory expansion beyond the default 512 MB configuration.
  • Comprehensive Ex Ratings: Engineered for hazardous locations with ATEX, IECEx, and cFMus Class I Division 2 certification.

Applications

  • Decentralized Processing Nodes: Distributed control architectures where independent, local decisions must be synchronized with a centralized master controller.
  • Substation Protocol Conversion: Bridging operational localized I/O nodes with high-level plant monitoring via the integrated 10/100 Mbit/s Ethernet port.
  • OEM Modular Machinery: Packaging, assembly, and conveyor subsystems requiring dedicated local computing, small physical footprints, and direct DIN-rail installation.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model Number CX8010
Processor ARM9, 400 MHz, 1 Core
Flash Memory 512 MB microSD (expandable)
Main Memory 64 MB DDR2 RAM (non-expandable)
Persistent Memory 1-second UPS (retains 1 MB persistent data)
Operating System Windows Embedded CE 6
Control Software TwinCAT 2 PLC runtime
Fieldbus Interface EtherCAT IN & OUT (2 x RJ45)
Local I/O Capacity E-bus or K-bus automatic detection (up to 2 A power supply)
Maximum Power Consumption 3 W
Dimensions (W x H x D) 64 mm x 100 mm x 73 mm
Environmental Temperature Operating: 0 to 55 degC | Storage: -25 to 85 degC
Relative Humidity 95% non-condensing
Protection Rating IP20
Ex Markings ATEX II 3 G Ex nA IIC T4 Gc / IECEx Ex nA IIC T4 Gc / cFMus Cl. I Div. 2
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Port / Physical Interface Technical Assignment & Function
1 x RJ45 (Ethernet) 10/100 Mbit/s Network link for system programming, visualization, and host connectivity.
2 x RJ45 (EtherCAT) Dedicated EtherCAT IN and OUT ports configured to act as an EtherCAT slave interface.
1 x USB Device Service-only USB connection positioned securely behind the front access panel.
I/O Bus Contact Slide Mechanical logic interface feeding power and data channels to connected E-bus or K-bus terminals.

Alternative Models & Compatibility

The CX8010 is specifically tailored as an EtherCAT slave. If your system design requires protocol mastership or communication over alternative industrial standards, consider the CX8090 (Ethernet/IP / Modbus TCP) or the CX8031 (PROFIBUS slave). Due to the hardware architecture running Windows CE 6, the CX8010 is not compatible with TwinCAT 3 runtime projects. Existing TwinCAT 2 software platforms must be utilized for compilation and program download.

Application Pitfalls & Engineering Notes

Ensure that the total power demand of the attached slice terminals does not exceed the 2 A current supply limit of the internal E-bus/K-bus power contacts. When designing dense terminal assemblies, utilize specialized power supply terminals (such as the EL9410) to inject additional current. The 1-second persistent data UPS is capacitive-based and relies on an internal charge cycle. If consecutive power loss cycles occur within rapid succession, the capacitor will not have recharged sufficiently to complete a secure write operation to the microSD card.

Commissioning & Wiring Tips

To maintain signal integrity on the EtherCAT line, use shielded Cat5e SF/UTP cables grounded directly at the panel penetrations. Ensure that the DIN rail has a direct, low-resistance ground path. At initial power-up, the CX8010 scans the physical Bus Terminal backplane. Do not mix K-bus and E-bus terminals within the same mechanical group, as the system will fault during the auto-detection phase. Always ensure the front protective flap is fully closed during operational runs to maintain the IP20 environmental rating and prevent contamination of the battery compartment.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources prior to mounting, disassembling, or wiring the controller. Failure to disconnect high-voltage systems can lead to structural damage to the CPU logic cards, terminal failure, or electrical shock. Confirm that all local safety standards are respected before energizing the device.

1

Mount the CX8010 vertically on standard 35 mm DIN rail (EN 60715) with the release tab pointing downward.

2

Slide local I/O terminals (E-bus or K-bus) onto the right-hand connection point until the mechanical lock clicks home.

3

Connect the 24V DC auxiliary power supply to the terminals on the integrated power supply module.

4

Connect network cables to the EtherCAT slave ports (IN/OUT) and complete initialization via TwinCAT System Manager.

Loading product navigation…

Can the CX8010 be configured to run TwinCAT 3 software?

No. The CX8010 is equipped with an ARM9 processor running Windows Embedded CE 6, which restricts its runtime configuration exclusively to the TwinCAT 2 programming environment.

How does the system distinguish between E-bus and K-bus terminals?

The CX8010 features an automatic physical bus detection sequence at startup. It queries the electronic data of the connected backplane to configure the corresponding bus control loop.

How is persistent variables data saved on sudden power failure?

The unit integrates a capacitive-based 1-second UPS. On loss of primary power, this storage holds sufficient energy to write up to 1 MB of persistent data to the non-volatile memory.

Does the CX8010 support fieldbus master operation?

No. The CX8010 is specifically configured as an EtherCAT slave interface unit. If master functionality is required, other models in the CX series must be used.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...