1 -ın, -in, -un, -ün (bağlama göre değişir) 1

BECKHOFF IP5009-B528 DeviceNet Fieldbus Box

BECKHOFF IP5009-B528 DeviceNet Fieldbus Box

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: IP5009-B528

  • Menşei ülke:Almanya

  • Ürün Türü: Fieldbus Boxes

  • Ödeme: T/T, Western Union

  • Ağırlık: 2000g

  • Boyutlar: 2 x 2 x 0.25 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Decentralized field automation requirements are directly addressed by the IP5009-B528, a high-performance DeviceNet fieldbus box engineered by Beckhoff for direct mounting in demanding industrial environments. This station connects digital and analog peripheral signals directly to DeviceNet networks without requiring a protective control cabinet. By utilizing integrated M12 tee-connector ports and M8 power feed-through interfaces, this module enables efficient line-topology wiring directly on the machinery.

The module supports configuration flexibility through either the Beckhoff KS2000 software suite or directly via the master controller using explicit messaging. The integrated electronics dynamically adapt to network transfer rates up to 500 kbaud. Electrical isolation of 500 V between the control voltage and the fieldbus line provides robust protection against transient noise and grounding loops, securing reliable I/O data transmission across varying plant distances.

Features

  • DeviceNet Integration: Full compatibility with DeviceNet physical layer and protocol specifications.
  • Automatic Baud Rate Detection: Automatically syncs with the master station at transmission speeds up to 500 kbaud.
  • Integrated Tee-Connector: Built-in 1 x M12 plug (5-pin) and 1 x M12 socket (5-pin) interfaces eliminate the need for external T-pieces.
  • Flexible I/O Mapping: Handles digital and analog peripheral signals based on the specific module extension and I/O layout.
  • Power Daisy-Chaining: Features an M8 male input and M8 female downstream power connection to feed control and load voltages.
  • Robust Environmental Housing: Rated up to IP67 for dust and water ingress protection, allowing direct machinery mounting without enclosures.

Applications

  • Automotive assembly lines and robotic welding cells
  • Packaging machinery and material handling conveyor networks
  • Water and wastewater processing systems with decentralized control nodes
  • General factory automation requiring IP67 distributed field I/O

Technical Specifications

ManufacturerPart Number / ModelFieldbus ProtocolData Transfer RatesBus InterfaceData Transfer MediumControl Voltage SupplyLoad Voltage SupplyPower Supply ConnectionBox Supply CurrentElectrical IsolationI/O Communication TypesOperating TemperatureStorage TemperatureVibration/Shock ResistanceEMC Immunity/EmissionProtection ClassInstallation PositionShipping Weight
BECKHOFF
IP5009-B528
DeviceNet
Automatic detection up to 500 kbaud
1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (tee-connector integrated)
Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
24 V DC (-15 % / +20 %)
According to connected I/O type
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
45 mA + current consumption of sensors (max. 0.5 A)
Control voltage/fieldbus: 500 V; Control voltage/I/O: according to I/O type
Bit strobe, polling, cyclic, change of state (COS)
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65/66/67 (conforms to EN 60529)
Variable
2.0 kg

Connections and Interfaces

Connection Interface Connector Type Function
Bus Input M12 Plug, 5-pin DeviceNet upstream fieldbus network connection
Bus Output M12 Socket, 5-pin DeviceNet downstream connection (integrated T-connector)
Power Input M8 Male Socket, 4-pin Feed control voltage (24 V DC) and sensor/actuator power
Power Output M8 Female Socket, 4-pin Downstream control and load voltage loop-through

Installation Guidelines

  • Mounting: Secure the unit to a flat, rigid machine surface using the integrated mounting flanges. Avoid mounting orientations that expose the connection points to continuous fluid pooling.
  • Grounding: Ensure a low-impedance connection to the machine ground. Use the provided mounting holes or local functional earth contacts.
  • Cabling and Torquing: All unused M12 and M8 ports must be sealed with appropriate protective caps to maintain the IP65/66/67 rating. Tighten mating connectors to the manufacturer-specified torque limits.
  • Cable Routing: Route fieldbus communication cables away from high-noise power lines, motor cables, and variable frequency drives to prevent electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What fieldbus protocol does the Beckhoff IP5009-B528 utilize?

The IP5009-B528 utilizes the DeviceNet fieldbus protocol, supporting automatic baud rate detection up to 500 kbaud.

How is the IP5009-B528 fieldbus box configured?

The module can be configured using the Beckhoff KS2000 configuration software or directly via the main controller using explicit messaging.

Does this module require an external junction or T-connector for network wiring?

No, the IP5009-B528 features an integrated tee-connector with 1 x M12 plug (5-pin) and 1 x M12 socket (5-pin) for direct network line routing.

What are the environmental ratings for this device?

The device features an IP65, IP66, and IP67 ingress protection rating, making it suitable for cabinet-free installation directly on machinery.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...