Description
Designed for multi-loop thermal management within the Sysmac automation platform, the Omron NX-TC3405 provides high-speed, high-precision temperature control across four independent channels. This NX Series module interfaces directly with the NX I/O bus, processing analog inputs from a wide variety of thermocouples and RTDs to drive precise heating or cooling control loops. With its compact form factor and integrated safety/fault detection capabilities, it optimizes panel space while maintaining high thermal stability in challenging industrial environments.
Key Features
-
4-Channel Isolated Input: Supports B, C (WRe5-26), E, J, JPt100, K, L, N, P (PLII), Pt100, R, S, T, and U sensor profiles.
-
High-Speed Processing: Extremely fast conversion time of 50 ms per unit ensures rapid closed-loop response.
-
PNP PWM Outputs: Four digital outputs rated at 24 VDC (21 mA per point) optimized for solid-state relay (SSR) control.
-
Heater Burnout Detection: Real-time monitoring of heater currents to detect failure events instantly.
-
Push-in Plus Terminals: Dual detachable 2-connector design reduces wiring time and guarantees vibration-resistant terminations.
Applications
- Plastics extrusion, blow molding, and injection molding barrel zone control.
- Form-fill-seal packaging machinery and sealing jaws.
- Industrial baking ovens, drying tunnels, and heat treatment furnaces.
- Semiconductor wafer processing chambers and environmental test equipment.
Technical Specifications
| Manufacturer |
Omron |
| Model Number |
NX-TC3405 |
| Module Type |
Temperature Control (4-Channel) |
| Control Loops |
4 Loops (Heat or Cool) |
| Input Types |
Thermocouple (B, C, E, J, K, L, N, P, R, S, T, U) / RTD (Pt100, JPt100) |
| Digital Outputs |
4 PNP PWM (24 VDC, 21 mA / point) |
| Conversion Time |
50 ms / unit |
| I/O Connection Type |
Push-In Plus (Detachable, 2 Connectors) |
| Enclosure Rating |
IP20 |
| Product Dimensions |
100 mm (H) x 24 mm (W) x 80 mm (D) |
| Unit Weight |
140 g |
| Shipping Weight (Calculated) |
1.00 kg |
| Package Dimensions (Calculated) |
150 mm x 120 mm x 50 mm |
Alternative Models & Compatibility
The NX-TC3405 belongs to the modular NX-series, which is compatible with NJ/NX CPU units and EtherCAT Coupler Units (such as the NX-ECC203). When replacing older systems or configuring custom control setups, note that the NX-TC3405 features PNP outputs (source logic). For NPN (sink logic) requirements, the NX-TC3406 should be specified. Furthermore, if only two control loops are required, consider the 2-channel NX-TC2405 to optimize panel layout and hardware costs.
Application Pitfalls & Engineering Notes
An essential engineering consideration is the 21 mA current limit per output point on the digital control channels. Attempting to directly switch high-draw inductive loads or mechanical relays will damage the internal output stage. Routing these outputs through a compatible solid-state relay (SSR) with a logic-level input is highly recommended. For accurate temperature readings, ensure that the thermocouple cold-junction sensor on the terminal block is not exposed to direct drafts from cooling fans inside the electrical cabinet, as local air currents can skew cold-junction compensation algorithms.
Commissioning & Wiring Tips
During initial configuration within Sysmac Studio, ensure that the selected input type corresponds exactly to the connected sensor (such as K-type or Pt100) to prevent calculation errors. Keep sensor wires separate from high-voltage AC lines to minimize electromagnetic noise coupling. Utilize shielded twisted-pair cables for thermocouple runs and ground the shield only at the control panel side. The Push-in Plus terminals support solid wires up to 1.5 mm2 or standard ferruled stranded wires; avoid tinned, bare stranded wires to ensure a reliable long-term gas-tight connection.
Installation Guidelines
CRITICAL WARNING
Ensure the entire PLC system is de-energized prior to installing, removing, or wiring the module. Working on live equipment risks destroying the sensitive internal bus interface of the NX backplane and presents a shock hazard. Confirm that the heater circuits are completely isolated before connecting the heater burnout sensing inputs.
1
Mount the module onto the DIN rail by aligning the top channel hook and pressing downward until the locking latch clicks firmly into place.
2
Slide the unit horizontally along the rail until it connects securely with the adjacent NX-series module, engaging the internal bus connectors.
3
Insert pre-insulated ferrules directly into the Push-in Plus terminals to complete the sensor and SSR output connections.