1 trong số 3

IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module with HART

IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module with HART

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC695ALG626

  • Country of origin:Hoa Kỳ

  • Product Type: Analog Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 3.5cm x 13.5cm x 13.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

IC695ALG626 (IC695ALG626) is a high-resolution analog input module designed for GE Fanuc PACSystems RX3i control platforms. The module provides 16 single-ended or 8 differential analog input channels with integrated HART 5.0 communication capability. Engineers deploy this module in turbine control systems, refinery process skids, power generation monitoring, and critical plant instrumentation where accurate analog acquisition is required.

The design integrates four internal HART modems and supports simultaneous analog and digital device diagnostics. Software configuration eliminates hardware jumpers and simplifies commissioning. Built-in autocalibration, advanced filtering, and high noise rejection maintain measurement stability in electrically harsh environments. The module supports voltage and current ranges including 4 to 20 mA loops commonly used in field transmitters. High resolution 24 bit ADC conversion ensures precise process feedback, reducing control drift and unexpected shutdown risks.

Technical Configuration

The IC695ALG626 installs into RX3i Universal Backplane and communicates directly with RX3i CPUs. Each channel supports independent configuration for voltage or current inputs. Four internal HART modems multiplex channel groups to enable device diagnostics without additional hardware.

The module supports:

  • 16 single ended or 8 differential inputs
  • HART 5.0 communication per channel group
  • 24 bit ADC conversion with floating point output
  • Software selectable filters from 8 Hz to 500 Hz
  • Per channel scaling and alarm configuration
  • Autocalibration at startup
  • Open circuit detection and fault reporting

Voltage and current ranges include:

  • 0 to 20 mA
  • 4 to 20 mA
  • plus minus 20 mA
  • plus minus 10 V
  • 0 to 10 V
  • plus minus 5 V
  • 0 to 5 V
  • 1 to 5 V

Technical Specifications

Parameter Specification
Model IC695ALG626
Brand GE Fanuc
Series PACSystems RX3i
Module Type Analog Input with HART
Channels 16 single ended or 8 differential
ADC Resolution 24 bit
Input Ranges Voltage and current configurable
HART Support Version 5.0
Backplane Power 600 mA at 5 VDC
Power Dissipation 7.35 W maximum
Isolation 250 VAC continuous
Input Impedance Greater than 100 kOhm
Overvoltage Protection plus minus 60 VDC continuous
Overcurrent Protection plus minus 28 mA continuous
Accuracy up to 0.05 percent of range
Operating Temperature 0 to 60 deg C
Dimensions Standard RX3i module
Origin USA
Weight Approx 0.32 kg

Technical FAQs

Does IC695ALG626 support HART communication on every channel?
Yes. The module supports HART communication through four internal modems. Channels are multiplexed into modem groups.

Which CPU is required for this module?
RX3i CPU firmware version 3.5 or later is required. Machine Edition 5.5 or newer configures the module.

Can the module work with differential inputs?
Yes. Configure the module for 8 differential inputs through software configuration.

What terminal blocks are compatible?
IC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132 terminal blocks are supported.


Engineering & Installation Guide

Use shielded twisted pair wiring for 4 to 20 mA HART loops. Ground the shield at one end only to avoid ground loops.

Distribute HART devices across channel groups 1, 5, 9, and 13 to minimize update time. This reduces multiplex delay.

Install the module in slots with adequate airflow. High channel count current mode increases thermal load.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module with HART

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...