1 of 1

Honeywell 51201420-005 Field Terminal Adapter (FTA) I/O Cable

Honeywell 51201420-005 Field Terminal Adapter (FTA) I/O Cable

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51201420-005

  • Country of origin:United States

  • Product Type: Field Terminal Adapter Cables

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The Honeywell 51201420-005 is a 5-meter non-shielded Field Terminal Adapter (FTA) I/O Cable designed to provide reliable signal connectivity between field devices and Honeywell control system termination assemblies. This cable is engineered for seamless integration in industrial automation cabinets, facilitating efficient data communication and signal distribution for various I/O configurations.

Features

  • Cable Length: 5 meters, suitable for standard cabinet-to-rack wiring configurations
  • Design: Non-shielded construction optimized for standard I/O signal transmission
  • Compatibility: Designed for use with Honeywell Field Terminal Adapter (FTA) systems
  • Application: Ideal for organized field-level signal termination and controller interconnectivity

Applications

  • Distributed Control System (DCS) I/O signal distribution
  • Cabinet-to-rack interconnection in industrial automation
  • Data transmission between control modules and field termination assemblies

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 51201420-005
Product Type Field Terminal Adapter (FTA) I/O Cable
Cable Length 5 meters
Shielding Non-shielded
Estimated Lead Time 4 - 6 weeks
Shipping Weight 3.0 kg

Installation Guidelines

  • Routing: Route the cable through dedicated signal wireways, ensuring it is kept separate from high-voltage power lines to prevent signal noise.
  • Bend Radius: Observe the manufacturer's recommended minimum bend radius during installation to prevent internal conductor damage or strain.
  • Termination: Ensure the connectors are fully seated and locked into the corresponding FTA and I/O module ports to maintain reliable electrical contact.
  • Cable Management: Use cable ties or wire ducting to secure the 5-meter length, preventing physical strain on the connectors caused by excess weight or vibration.

What is the length of the 51201420-005 cable?

The 51201420-005 is a 5-meter I/O cable.

Is this cable shielded?

No, this specific model is a non-shielded FTA cable.

What is the typical lead time for this cable?

The estimated lead time for this product is 4 to 6 weeks.

What is the primary function of an FTA cable?

An FTA cable acts as the interface link between the controller I/O modules and the field terminal adapter, allowing for efficient signal routing in DCS cabinets.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...