DELTA AH10SCM-5A AH500 Series Serial Communication Module

DELTA AH10SCM-5A AH500 Series Serial Communication Module

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: AH10SCM-5A

  • Country of origin:Тайван

  • Product Type: Network Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Product Overview

The AH10SCM-5A (AH10SCM5A) is a high-performance serial communication module designed for the Delta AH500 redundant rack-based PLC system. Engineered for complex multi-device networking, this module provides dual-channel RS-422/485 connectivity, enabling the PLC to act as a central coordinator in large-scale industrial architectures. With a focus on system resilience, the AH10SCM-5A features a full isolation design between power and signal circuits, ensuring that transient electrical noise from the field does not compromise the CPU's integrity. It is an essential component for applications requiring high-speed data exchange with Variable Frequency Drives (VFDs), sensors, and third-party instruments in sectors such as water treatment, HVAC (via BACnet), and smart manufacturing.

Technical Configuration

The AH10SCM-5A is a versatile Master/Slave communication hub supporting high-speed transmission up to 460.8 kbps. It is equipped with two independent serial ports that can be configured for various protocols, including Modbus RTU/ASCII and BACnet Slave. A key technical advantage is the "UD Link" (User Defined Link) capability, which allows engineers to customize communication formats for non-standard serial devices. Furthermore, the module supports hot-swapping, allowing for maintenance or replacement without shutting down the entire PLC rack, thereby maximizing system uptime in continuous processing environments.

Technical Specifications

Attribute Specification
Model AH10SCM-5A
Brand DELTA
Origin Taiwan
Module Type Serial Communication Module (RS-422 / RS-485)
Communication Ports 2 Ports
Max Baud Rate 460.8 kbps
Power Consumption 1.2 W (Internal)
Protocols Modbus RTU/ASCII, BACnet Slave, UD Link, PLC Link
Isolation Full isolation (Power and Signal)
Operating Temp -20 to 60 deg C
Special Features Hot-swapping, Automatic Data Exchange
Weight 0.5 kg (Shipping weight 2.0 kg)

Technical FAQs

Can the AH10SCM-5A manage data exchange automatically without complex PLC ladder logic?

Yes. The module supports an "Automatic Data Exchange" function. Once the communication parameters and data addresses are configured in the software, the module handles the polling and data mapping between the PLC registers and the slave devices independently of the CPU scan cycle.

Is this module compatible with building automation systems?

Absolutely. The AH10SCM-5A supports the BACnet Slave function, making it compatible with building management systems (BMS). This allows the AH500 PLC to report status and receive commands from higher-level HVAC and lighting control networks.

What is the benefit of the full isolation design in this module?

The full isolation design prevents ground loops and protects the internal PLC backplane from high-voltage transients that may occur on long-distance RS-485 field wiring. This is critical for maintaining communication stability in environments with heavy electromagnetic interference.


Engineering & Installation Guide

  • Hot-Swapping Protocol: When utilizing the hot-swap feature, ensure the module's locking levers are fully released before extraction. The AH500 backplane will automatically detect the removal; however, ensure that the "Automatic Data Exchange" settings are backed up in the CPU to allow the replacement module to resume operation immediately upon insertion.

  • Termination Resistors: For long-distance RS-485 networks (exceeding 100 meters), ensure that a 120-ohm termination resistor is enabled at both physical ends of the communication line. This prevents signal reflection and ensures data integrity at the maximum 460.8 kbps baud rate.

  • Shielding and Grounding: Use shielded twisted-pair (STP) cables for all RS-422/485 connections. The shield should be grounded at a single point (typically at the PLC cabinet side) to prevent circulating currents while providing effective protection against RFI/EMI.

 

Key Features:

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Черно
Country of origin
Тайван

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...