The 1768-ENBT is a CompactLogix EtherNet/IP Communication Module developed by Allen-Bradley to provide dedicated Ethernet networking capabilities for 1768 control systems. This module establishes reliable data transmission links across an industrial network, enabling seamless connectivity with multiple Logix5000 controllers, supervisory computers, and auxiliary automation equipment. It processes network traffic over a integrated communication interface while managing local status via an alphanumeric display and built-in diagnostic indicators. Designed as an open-type component, it installs directly within a synchronized hardware stack consisting of a 1768 controller and compatible power supplies to optimize throughput and minimize communication downtime.

Features

  • Provides automated data management over EtherNet/IP networks to reduce packet collisions and sustain optimal bandwidth.
  • Features an integrated alphanumeric display and three bi-color diagnostic status indicators (NET, Link, and OK) for rapid local troubleshooting.
  • Supports high-speed data transmission over standard Category 5 or Category 5e cabling using a rugged RJ45 connector interface.
  • Implements reliable electrical protection with a continuous functional insulation rating of 30V between the Ethernet network and internal system circuits.
  • Interfaces directly with specialized 1768 CompactLogix system components and supports flexible expansion using combined 1769-series I/O modules.

Applications

  • Distributed industrial automation and manufacturing plant network management.
  • Inter-controller data synchronization across multiple Logix5000 systems.
  • SCADA network routing and remote control system interface integration.

Technical Specifications

Parameter Specification
Backplane Current 834 mA at 5.2V DC
Power Consumption 4.34 W
Power Dissipation 4.38 W
Isolation Voltage 30V (continuous-voltage rating), Functional Insulation Type, Ethernet network to system (Type tested at 710V DC for 60 s)
Wire Size RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wiring Category 2 - on communication ports
North American Temp Code T4A
IEC Temp Code T4
Mounting Screw Torque 1.16 N.m (10 lb.in) using M4 or #8 screws
Dimensions (HxWxD), Approx. 132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.)
Weight, Approx. 0.213 kg (7.5 oz)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 5 g @ 10...500 Hz
Operating Shock 30 g
Nonoperating Shock 50 g
Emissions CISPR 11 Group 1, Class A
Enclosure Type Rating None (open-style)

Connections/Interfaces

Connector Pin Function
Pin 1 TD+ (Transmit Data +)
Pin 2 TD- (Transmit Data -)
Pin 3 RD+ (Receive Data +)
Pin 4 NC (No Connection)
Pin 5 NC (No Connection)
Pin 6 RD- (Receive Data -)
Pin 7 NC (No Connection)
Pin 8 NC (No Connection)

Installation Guidelines

  • Plan for a minimum hardware clearance of 105 mm (4 in.) at the top and bottom, and 90 mm (3.54 in.) on the sides from enclosure walls, wireways, and adjacent machinery.
  • Ensure the system is grounded through the DIN rail to the chassis ground by utilizing zinc-plated yellow-chromate steel DIN rail; avoid aluminum or plastic rails which can oxidize and cause poor conductivity.
  • Secure the mounting DIN rail to the surface approximately every 200 mm (7.87 in.) and install appropriate end-anchors to hold modules firmly.
  • If choosing panel mounting instead of DIN rail installation, mark pilot holes using the hardware as a template, drill holes for M4 or #8 screws, and tighten to 1.16 N.m (10 lb.in) of torque. Do not use screws and DIN rail concurrently.
  • Connect the network interface cable to a 100 MB Ethernet switch rather than a shared hub to increase network bandwidth and reduce lost packets.
  • Never connect or disconnect network communication cables while power is actively applied, as an electrical arc can occur and present an explosion hazard in certified environments.
  • Always wait for all diagnostic status lights on the power supply and controller to turn completely off before disconnecting any system module to allow the processor sufficient time to finish writing project parameters to non-volatile memory.
  • Mitigate static risks by touching a grounded object, wearing an approved grounding wriststrap, and strictly avoiding contact with component board pins, connectors, or internal circuit elements.

Compliance and Certifications

  • c-UL-us Listed Industrial Control Equipment, Certified for US and Canada (UL File E65584)
  • c-UL-us Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, Certified for US and Canada (UL File E194810)
  • CE Certified (European Union 2004/108/EC EMC Directive, compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2)
  • C-Tick Compliant (Australian Radiocommunications Act, compliant with AS/NZS CISPR 11)
  • Ex Certified (European Union 94/9/EC ATEX Directive, compliant with EN 60079-15 and EN 60079-0; II 3 G Ex nA IIC T4)
  • EtherNet/IP ODVA Conformance Tested
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1768-ENBT CompactLogix EtherNet/IP Communication Module

Was bedeutet ein blinkender roter Status am NET-Anzeiger?

Ein blinkender roter Netzwerk-(NET)-Anzeiger zeigt an, dass eine oder mehrere der aufgebauten Verbindungen, bei denen das Kommunikationsmodul als Zielgerät fungiert, eine Zeitüberschreitung erfahren haben.

Warum müssen Installateure warten, bis alle Statusleuchten erloschen sind, bevor sie die Hardware trennen?

Wenn die Systemspannung ausgeschaltet wird, schreibt der Hauptcontroller seine aktiven Projektdaten in den nichtflüchtigen Speicher. Das Trennen der Module, bevor alle Statusleuchten erloschen sind, unterbricht diesen Vorgang, was zum unwiederbringlichen Verlust des Steuerprogramms führt.

Was passiert, wenn die OK-Statusanzeige ein blinkendes rotes und grünes Muster zeigt?

Ein blinkendes rotes und grünes Muster auf der OK-Anzeige zeigt an, dass das Kommunikationsmodul aktiv seine standardmäßigen Selbsttest-Routinen beim Hochfahren ausführt.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Color pattern
Grauweiß
Country of origin
Vereinigte Staaten
Power source
Gleichstromversorgung

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...