1 von 1

Delta Electronics VFD450C43A C2000 Series Variable Frequency Drive

Delta Electronics VFD450C43A C2000 Series Variable Frequency Drive

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: Delta Electronics

  • Produkt-Nr.: VFD450C43A

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Variable Frequency Drives

  • Zahlung: T/T, Western Union

  • Gewicht: 500g

  • Abmessungen: 275 mm x 330 mm x 275 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Optimized for high-performance field-oriented control in demanding automation environments, the Delta Electronics VFD450C43A functions as a highly adaptable 3-phase AC motor drive within the C2000 Series. This variable frequency drive supports both induction and permanent magnet motors, featuring a dual-rating design that allows seamless transitions between Normal Duty (ND) and Heavy Duty (HD) profiles. Engineered with integrated PLC capabilities and modular expansion options, it delivers precise speed, torque, and position control for sophisticated industrial machinery.

Features

  • Dual-Rating Capability: Easily configured for Normal Duty (45 kW / 60 HP) or Heavy Duty (37 kW / 50 HP) operation based on application dynamics.
  • Advanced FOC Control: High-bandwidth field-oriented control ensures rapid torque response and exceptional low-speed stability.
  • Built-In Logical Control: Features an integrated PLC for executing localized logic routines without requiring external microcontrollers.
  • Robust Harmonics Mitigation: Built-in DC reactor significantly reduces mains-borne harmonic distortion and stabilizes DC bus voltage.
  • Flexible Communication: Native MODBUS protocol support, expandable with optional fieldbus modules for high-speed network integration.

Applications

  • Heavy-duty hoisting, crane trolley movements, and winching mechanisms.
  • High-capacity extrusion lines, plastic molding machinery, and chemical mixers.
  • Municipal water distribution pumps and large-scale HVAC air handling units.
  • Industrial manufacturing conveyors and automated material handling systems.

Technical Specifications

Parameter Normal Duty (ND) Specification Heavy Duty (HD) Specification
Applicable Motor Output 45 kW (60 HP) 37 kW (50 HP)
Rated Output Current 91 A 86 A
Rated Output Capacity 73 kVA 69 kVA
Max Output Frequency 0.00 to 599.00 Hz 0.00 to 300.00 Hz
Carrier Frequency 2 to 10 kHz (Default: 6 kHz) 2 to 6 kHz (Default: 2 kHz)
Input Voltage / Phase 3-Phase, 380 to 480 VAC (50/60 Hz)
Cooling Method Forced Air Cooling
Enclosure Rating IP20 / UL Type 1
Dimensions (W x H x D) 275 mm x 330 mm x 275 mm
Net Weight 27.0 kg
Shipping Weight (Calculated) 28.0 kg

Connections and Interfaces

Terminal / Port Function Description
R/L1, S/L2, T/L3 3-Phase AC mains power input connections
U/T1, V/T2, W/T3 3-Phase AC output connection to the motor
+1, +2 External DC reactor connection point (jumpered by default)
RE/PE Dedicated low-impedance ground safety earth connection
Control Terminals Analog inputs/outputs, digital inputs, relay outputs, and RJ-45 MODBUS interface

Alternative Models & Compatibility

When transitioning from legacy Delta legacy drives such as the VFD-F or VFD-B series, ensure that you map control terminal parameters to the new C2000 environment. While physical footprint variances are minimal for Frame C, check your cabinet depth clearance since the integrated DC reactor structure modifies the overall chassis projection slightly compared to older models.

Application Pitfalls & Engineering Notes

Operating at elevated carrier frequencies (above 6 kHz in Normal Duty or above 2 kHz in Heavy Duty) yields lower motor acoustic noise but increases thermal losses in the drive's output IGBT bridge. In hot enclosure environments exceeding 40 degC, you must apply appropriate current de-rating curves to prevent premature over-temperature faults (oH1/oH2). Additionally, dynamic braking applications with heavy duty cycles require a correctly sized external dynamic braking unit (DBU) and resistor network.

Commissioning & Wiring Tips

To prevent electromagnetic interference (EMI) from disrupting nearby instrumentation, utilize symmetrical shielded motor cabling and ground the shield at both the drive plate and motor junction box. Ensure the control terminal shield is grounded strictly at the drive end. Before operating permanent magnet motors, complete a full rotational or stationary auto-tune procedure using the digital keypad to map stator resistance and inductance metrics accurately.

Installation Guidelines

CRITICAL WARNING: Hazardous residual voltage remains stored in the internal DC bus capacitors even after mains power is disconnected. Prior to starting any wiring work or maintenance inside the chassis, disconnect all incoming power supplies and wait a minimum of 10 minutes. Use a reliable digital multimeter to verify that the DC bus voltage across terminals (+1 and -) has dropped below 36 VDC.
1

Mount the drive vertically on a flat, non-flammable surface to allow unhindered vertical convective cooling airflow through the heatsink fin assembly.

2

Connect the safety protective earth (PE) conductor to the designated chassis grounding terminal prior to running power and control wiring.

3

Verify proper phase torque settings on the primary power terminals (R/L1, S/L2, T/L3) and the motor connection terminals (U/T1, V/T2, W/T3) to prevent loose-connection hot spots.

Loading product navigation…

What is the primary difference between Normal Duty and Heavy Duty on this drive?

Normal Duty (ND) is rated for 45 kW (60 HP) with a max carrier frequency of 10 kHz, while Heavy Duty (HD) is configured for 37 kW (50 HP) with a carrier frequency capped at 6 kHz, offering higher overload tolerance for high-torque startups.

Can this unit control permanent magnet (PM) motors?

Yes. This drive features advanced field-oriented control (FOC) algorithms supporting both induction and permanent magnet synchronous motors (PMSM) via standard open-loop or closed-loop feedback interfaces.

What should I do if the drive triggers an oH1 fault?

Check for airflow obstructions through the heatsink, ensure the internal cooling fan is running properly, and verify that the ambient enclosure temperature has not exceeded 40 degC. Consider dropping the carrier frequency parameter to reduce internal IGBT thermal load.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...