Designed to bridge the gap between high-speed EtherCAT networks and standard K-bus assemblies, the BK1120 serves as an efficient communication interface for modular automation systems. This bus coupler maps the technical signals from standard Beckhoff Bus Terminals directly into the EtherCAT protocol, enabling seamless integration into distributed control architectures without sacrificing legacy terminal compatibility.

The BK1120 establishes a high-performance link between physical I/O points and the controller. It automatically handles the conversion of process data and local bus diagnostic information, presenting it clearly to the EtherCAT master. With dual RJ45 interfaces, this module supports flexible line and daisy-chain topologies, simplifying field wiring and reducing installation costs in complex control environments.

Features

  • Direct integration of standard K-bus terminals into high-speed EtherCAT networks.
  • Supports up to 64 standard Bus Terminals directly, and up to 255 Bus Terminals using K-bus extensions.
  • Equipped with two RJ45 ports for line topology networking up to 100 meters apart.
  • High-density data handling with up to 1024 bytes of input and 1024 bytes of output process data.
  • Integrated diagnostic LEDs for quick monitoring of power status, K-bus run, and network communication.

Applications

  • Industrial machinery and high-speed packaging lines.
  • Distributed I/O architectures in processing and manufacturing systems.
  • Retrofitting existing legacy K-bus terminal configurations to modern EtherCAT masters.
  • Building automation and HVAC control infrastructure requiring high-density point aggregation.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model BK1120
Product Type EtherCAT Bus Coupler for standard Bus Terminals
Number of Bus Terminals 64 (up to 255 with K-bus extension)
Max. Process Data Space 1024 bytes input / 1024 bytes output
Bus Interface 2 x RJ45
Distance Between Stations Max. 100 m (100BASE-TX)
Power Supply 24 V DC (-15 % / +20 %)
Input Current 70 mA + (total K-bus current)/4 (500 mA max.)
Starting Current Approx. 2.5 x continuous current
Current Supply K-Bus 1750 mA
Power Contacts Max. 24 V DC / Max. 10 A
Recommended Fuse <= 10 A
Electrical Isolation 500 V (power contact / functional ground / K-bus)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, no condensation
Weight Approx. 0.15 kg

Connections and Interfaces

Interface Type Function
RJ45 Port 1 (IN) EtherCAT signal input connection from previous station or master
RJ45 Port 2 (OUT) EtherCAT signal output connection to next station in daisy-chain
Spring Force Terminals 24 V DC power supply input and power contact distribution feed

Installation Guidelines

  • Mounting: Install on a standard 35 mm DIN rail (EN 60715). Ensure the mounting slide latches firmly onto the rail.
  • Cabling: Use category 5e (or higher) shielded Ethernet cables to guarantee proper signal integrity and noise immunity.
  • Grounding: Ensure the DIN rail is reliably connected to a low-impedance functional earth grounding point.
  • Power Supply Routing: Keep power lines as short as possible and separate them from high-frequency signal cables to prevent interference.
Loading product navigation…

What is the maximum number of Bus Terminals supported by the BK1120?

The BK1120 directly supports up to 64 standard Bus Terminals. If a K-bus extension is used, this capacity can be expanded up to 255 terminals.

What Ethernet cables should be used with the BK1120?

It is recommended to use Cat5e (or higher) shielded twisted pair (STP) Ethernet cables to ensure reliable high-speed data transmission over EtherCAT.

What is the maximum current capacity supplied to the K-bus by the BK1120?

The BK1120 provides a maximum current supply of 1750 mA to the internal K-bus for attached terminals.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیالات: آموزش عملی

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...