1 از 1

BECKHOFF EL6751 EtherCAT Terminal CANopen Master/Slave Module

BECKHOFF EL6751 EtherCAT Terminal CANopen Master/Slave Module

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: EL6751

  • کشور سازنده:آلمان

  • نوع محصول: EtherCAT Terminals

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 70g

  • ابعاد: 24 mm x 100 mm x 52 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Engineered to bridge fieldbus technologies, the Beckhoff EL6751 serves as a high-performance 1-channel CANopen master/slave interface within an EtherCAT Terminal system. This communication terminal enables the seamless integration of CANopen-compliant fieldbus devices directly into the high-speed EtherCAT network. It can act as a CANopen network master and manager, or optionally operate as a CANopen slave, providing flexible architecture options for decentralized industrial networks.

The EL6751 offers robust galvanic decoupling and a standard 9-pin D-sub interface to ensure clean, noise-immune signal transmission in harsh industrial environments. By supporting both standard CANopen communication profiles and RAW-CAN protocol options, this terminal accommodates a wide range of legacy and modern automation devices.

Features

  • Single-channel communication interface supporting CANopen master, CANopen manager, or optional CANopen slave operation.
  • Galvanically decoupled D-sub interface (9-pin) conforming to standard CANopen specifications.
  • Flexible data transfer rates ranging from 10 kbaud up to 1,000 kbaud (1 Mbaud).
  • Comprehensive hardware diagnostics via integrated status LEDs.
  • Supports RAW-CAN protocol for customized CAN bus communication requirements.
  • Compact 24 mm terminal housing with integrated slot-and-key side-by-side mounting.

Applications

  • Industrial manufacturing plants utilizing distributed fieldbus architectures.
  • Integration of legacy CANopen-compliant sensors, actuators, and drives into EtherCAT networks.
  • Heavy machinery and specialized control systems requiring CANopen master/slave configuration.
  • Process automation and water treatment plants utilizing hybrid fieldbus solutions.

Technical Specifications

CategorySpecification ParameterValue / Details
Identification Manufacturer BECKHOFF
Part Number / Model EL6751
Communication & Fieldbus Fieldbus Type CANopen
Number of Channels 1
Supported Baud Rates 10, 20, 50, 100, 125, 250, 500, 800, 1000 kbaud
Protocol Compatibility CANopen Network Master, CANopen Manager, CANopen Slave, RAW-CAN
Interface Type D-sub connector, 9-pin (galvanically decoupled)
Electrical Specifications Current Consumption (E-bus) Typ. 230 mA
Hardware Diagnostics Status LEDs
Environmental & Mechanical Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20 (variable installation position)
Standards & Testing Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Ex Marking II 3 G Ex nA IIC T4 Gc
Physical Dimensions Housing Material Polycarbonate
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Installation / Mounting 35 mm DIN rail (EN 60715) with locking mechanism
Weight Approx. 70 g

Connections and Interfaces

Connector Pin (D-sub 9) Function / Signal
Pin 2 CAN_L (CAN bus signal dominant low)
Pin 3 CAN_GND (Ground)
Pin 7 CAN_H (CAN bus signal dominant high)
Pin 9 CAN_V+ (Optional external positive supply)
Pins 1, 4, 5, 6, 8 Reserved / Not connected

Installation Guidelines

  • Mounting: Mount the terminal on a standard 35 mm DIN rail (conforming to EN 60715). Ensure the locking mechanism is securely engaged.
  • Wiring: Use the dedicated push-in connection technology for E-bus integration. For the CANopen interface, utilize a shielded 9-pin D-sub connector.
  • Shielding & Grounding: Ensure proper shield grounding of the CAN network cable to maintain electromagnetic compatibility (EMC) and prevent signal degradation.
  • Hazardous Areas: When operating under ATEX II 3 G Ex nA IIC T4 Gc conditions, install the terminal inside an enclosure providing at least IP54 protection conforming to EN 60079-15.

Compliance and Certifications

  • CE
  • UL Listed
  • ATEX (II 3 G Ex nA IIC T4 Gc)
Loading product navigation…

What is the primary function of the Beckhoff EL6751?

The Beckhoff EL6751 serves as a 1-channel CANopen communication interface terminal, allowing the integration of CANopen devices (operating as either master, manager, or slave) into a high-performance EtherCAT network.

What data transfer rates does the EL6751 support?

The EL6751 supports CANopen data transfer rates of 10, 20, 50, 100, 125, 250, 500, 800, and 1000 kbaud.

Is the D-sub interface on the EL6751 galvanically isolated?

Yes, the 9-pin D-sub connector interface on the EL6751 terminal is galvanically decoupled to prevent electrical noise and ground loops.

Does this terminal support custom CAN protocols?

Yes, the EL6751 supports RAW-CAN, allowing developers to implement customized CAN-based protocols.

What are the environmental temperature limits for the EL6751?

The operating temperature range is -25 degC to +60 degC, and the storage temperature range is -40 degC to +85 degC.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...