Beckhoff EP6002-0002 EtherCAT Box Serial Interface Module

Beckhoff EP6002-0002 EtherCAT Box Serial Interface Module

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: EP6002-0002

  • کشور سازنده:آلمان

  • نوع محصول: Serial Interface Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 165g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Industrial serial communication tasks demanding IP67-level environmental protection are directly addressed by the Beckhoff EP6002-0002 serial interface module. This ruggedized EtherCAT Box enables the decentralized integration of up to two serial end devices directly in the field, bypassing the need for protective control cabinets. Each of the two channels can be configured independently, allowing simultaneous operation of RS232, RS422, or RS485 protocols. The module executes rapid, bi-directional data transfer to the controller via the high-performance EtherCAT protocol, establishing an efficient interface for bar code scanners, operator terminals, serial sensors, and legacy industrial devices.

The transmission parameters, including baud rates up to 115,200 baud, parity, and stop bits, are software-selectable to match diverse device requirements. To prevent signal interference and isolate delicate terminal equipment, the EP6002-0002 features integrated 500 V electrical isolation between the communication interfaces and the internal EtherCAT system logic. Encased in a compact, field-ready housing with a high ingress rating, it supports flexible mounting and straightforward integration into highly distributed factory automation topologies.

Features

  • Dual-channel design supporting independent interface selection (RS232, RS422, or RS485) per channel.
  • Direct integration into high-speed EtherCAT networks via dual M8 shielded connection ports.
  • Generous onboard data buffering with an 864-byte receive buffer and 128-byte transmit buffer per channel.
  • Electrically isolated, short-circuit proof +5 V DC auxiliary sensor power supply (20 mA per channel).
  • Robust IP65/66/67 protection rating for direct machine mounting in harsh industrial environments.
  • High-quality M12 connector interfaces ensuring secure, vibration-resistant connections for serial peripherals.

Applications

  • Decentralized barcode reader and RFID scanner integration on material handling conveyors.
  • Field connection of serial weight indicators and industrial scales in packaging systems.
  • Direct interfacing with legacy variable speed drives and positioning systems using Modbus RTU (via RS485).
  • Connecting operator panels, serial displays, and diagnostic terminals in process plant layouts.

Technical Specifications

ManufacturerPart Number / ModelProtocolBus InterfaceNumber of ChannelsSelectable InterfacesData Transfer RatesBit DistortionData Buffer
  • Maximum Cable Length
  • RS232RS422 / RS485Sensor SupplyNominal VoltageCurrent Consumption from USPower Supply ConnectionElectrical IsolationProtection RatingOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionDevice Weight
    Beckhoff Automation GmbH & Co. KG
    EP6002-0002
    EtherCAT
    2 x M8 socket, shielded, screw-type connection
    2 (TxD and RxD, full duplex)
    RS232, RS422, RS485
    300 to 115,200 baud (9600 baud preset, 8 data bits, no parity, 1 stop bit)
    Less than 3 percent
    864 bytes receive buffer, 128 bytes transmit buffer
    Max. 15 m
    Approx. 1000 m
    +5 V DC, 20 mA per channel, electrically isolated
    24 V DC (-15 percent / +20 percent)
    Typ. 130 mA + sensor supply current
    Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
    500 V
    IP65, IP66, IP67 (conforms to EN 60529)
    -25 to +60 degC
    -40 to +85 degC
    Conforms to EN 60068-2-6 / EN 60068-2-27
    Conforms to EN 61000-6-2 / EN 61000-6-4
    Approx. 165 g

    Connections and Interfaces

    Connection Type Connector / Socket Pinout Function
    EtherCAT Bus 2 x M8 socket, shielded Inbound and outbound EtherCAT communication lines
    Serial Interfaces 2 x M12 socket, 5-pin, A-coded RS232 / RS422 / RS485 connection and +5 V DC sensor supply
    Power Supply Infeed 1 x M8 male connector, 4-pin 24 V DC control and peripheral voltage input (US/UP)
    Power Supply Loop 1 x M8 female connector, 4-pin 24 V DC downstream power distribution to adjacent modules

    Installation Guidelines

    • Mounting: Mount the unit directly onto a flat, even surface using standard M3 bolts through the designated mounting holes. Do not exceed the maximum mounting torque.
    • Grounding and Shielding: Ensure the module is properly grounded. Use shielded M8 and M12 cables to maintain high electromagnetic compatibility (EMC) standards and minimize signal noise.
    • Cable Tightening: Hand-tighten all M8 and M12 circular connectors to ensure internal seals are compressed. Torque to nominal OEM recommendations to preserve the IP67 ingress protection rating.
    • Power Distribution: Observe voltage drops when daisy-chaining multiple modules via the M8 power loop. Do not exceed the maximum current carrying capacities of the power connections.

    Compliance and Certifications

    • CE
    • UL
    • ATEX: II 3 G Ex nA IIC T4 Gc
    Loading product navigation…

    Which serial communication protocols are supported by the Beckhoff EP6002-0002?

    The EP6002-0002 supports RS232, RS422, and RS485 serial standards. Each of the two channels can be configured independently to use any of these physical layers.

    What is the ingress protection rating of the EP6002-0002 EtherCAT Box?

    The module features an IP65/66/67 rating, making it completely dust-tight and resistant to high-pressure water jets and temporary immersion. This allows direct installation on machinery without an enclosure.

    Does the EP6002-0002 provide power to connected serial devices or sensors?

    Yes, it provides an electrically isolated, short-circuit-proof auxiliary sensor supply of +5 V DC up to 20 mA per channel.

    What are the configuration defaults for the serial interfaces on this module?

    The preset configuration is set to 9600 baud, 8 data bits, no parity, and 1 stop bit, but it can be adjusted via EtherCAT startup parameters up to 115,200 baud.

    What ATEX hazardous area classification does the EP6002-0002 carry?

    The module is certified with the Ex marking II 3 G Ex nA IIC T4 Gc, permitting safe installation in Zone 2 hazardous environments.

    ارسال سریع جهانی

    • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
    • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
    • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

    بازگشت کالا و گارانتی

    • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
    • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

    سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


    برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

    TECHNICAL SPECIFICATIONS

    Country of origin
    آلمان

    محصولات مشاهده‌شده اخیر

    دانش فنی

    عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

    این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

    عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

    این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

    منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

    این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

    منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

    منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

    راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

    فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

    راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

    گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...