Description

Designed for decentralized automation tasks in rugged environments, the EPP1816-0008 EtherCAT P Box acquires binary control signals from the physical process level and transmits them with high speed and synchronization to the control system. The unit is equipped with 16 digital inputs configured in a highly dense arrangement, accessible via a standard 25-pin D-sub interface.

Operating as an EtherCAT P device, this module integrates both ultra-fast EtherCAT communication and power distribution (for both system/sensor supply Us and peripheral voltage Up) into a single, specialized cable. The inputs conform to the EN 61131-2 Type 1 and Type 3 electronic standards, ensuring broad compatibility with 2-wire and 3-wire proximity sensors, limit switches, and photoelectric sensors. Built-in Distributed Clocks functionality guarantees precise latching of input states relative to the master system time.

Features

  • 16 digital input channels packaged in a compact, field-mountable form factor.
  • Unified EtherCAT P interface integrating power and signal on P-coded M8 connectors.
  • Concentrated sensor connection via a 25-pin D-sub socket with UNC4-40 locking threads.
  • Short-circuit proof, integrated sensor supply derived directly from the Us control voltage.
  • Hardware-supported Distributed Clocks for microsecond-precise input sampling.
  • IP67-rated enclosure allowing mounting outside electrical control cabinets.

Applications

  • High-density sensor data acquisition in assembly and packaging machinery.
  • Decentralized input mapping in conveyor and material handling systems.
  • Automated production lines requiring field-level modular expansions.
  • Machine tool control and robotics end-of-arm tool feedback integration.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Part Number / Model EPP1816-0008
Protocol EtherCAT P
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Number of Inputs 16
Input Connection D-sub socket, 25-pin, UNC4-40
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter 10 us (microseconds)
"0" Signal Voltage -3 to +5 V (conforming to EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (conforming to EN 61131-2, type 3)
Input Current Typically 3 mA (conforming to EN 61131-2, type 3)
Distributed Clocks Yes
Sensor Supply From Us control voltage, max. 0.5 A total, short-circuit proof
Current Consumption from Us Typically 100 mA
Electrical Isolation 500 V
Weight Approx. 165 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Connections and Interfaces

Connector Interface Type Function
EtherCAT P Input M8, 4-pin socket, P-coded EtherCAT P incoming communication and power feed (Us, Up)
EtherCAT P Output M8, 4-pin socket, P-coded EtherCAT P downstream communication and power forwarding
Digital Inputs 25-pin D-sub socket (UNC4-40 thread) 16-channel input terminals, including sensor supply and GND

Installation Guidelines

  • Ensure the installation surface is flat and clean to guarantee a proper seal when mounting. Secure the housing using M3 screws through the integrated mounting holes.
  • Use only pre-assembled, shielded EtherCAT P cabling with P-coded M8 connectors to protect the physical layer and preserve the IP67 protection class.
  • When connecting sensors via the 25-pin D-sub interface, verify that the total load current drawn does not exceed the maximum sensor supply rating of 0.5 A.
  • Establish a reliable, low-impedance ground connection via the mounting profile or the designated grounding point on the module's body.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What connection interface is used for the digital inputs on the Beckhoff EPP1816-0008?

The digital inputs are concentrated on a single, high-density 25-pin D-sub socket equipped with UNC4-40 locking threads.

Does this module support Distributed Clocks (DC)?

Yes, the EPP1816-0008 features integrated Distributed Clocks, allowing highly precise and synchronized input latching across the EtherCAT network.

What is the maximum sensor supply current available from the module?

The module provides a short-circuit-proof sensor supply of up to 0.5 A in total, derived from the Us control voltage.

Can this EtherCAT P box be mounted in harsh environments without an enclosure?

Yes, it is rated IP65, IP66, and IP67 in compliance with EN 60529, making it suitable for direct field mounting outside electrical cabinets.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه (به جز تعطیلات رسمی) پردازش و تحویل داده می‌شوند.


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...