Engineered for decentralized industrial topologies, the Beckhoff ER1258-0002 EtherCAT Box functions as an IP67-rated digital input interface designed to capture high-speed signals under extreme environmental conditions. This module features 8 digital inputs, including two channels equipped with sub-microsecond timestamping functionalities. Encased in a robust zinc die-cast housing, the Beckhoff ER1258-0002 processes signal states directly at the machine level, bypassing the need for protective control cabinets and minimizing field wiring complexity.

Key Features

  • Precise Timestamping: Channels 0 and 1 support Distributed Clocks (DC) with a 1 ns timestamp resolution for high-accuracy event logging.
  • Industrial Protection: IP65, IP66, and IP67 sealed rating for direct machine-mount installation without an enclosure.
  • Heavy-Duty Housing: Zinc die-cast construction offers superior resistance to mechanical shock, vibration, and corrosive elements.
  • Standardized Connectivity: M12 input connections paired with M8 EtherCAT and power interfaces guarantee secure, vibration-proof wiring.
  • Short-Circuit Protection: Integrated sensor supply tracking from the control voltage with a total current limit of 0.5 A.

Applications

  • High-speed packaging machinery requiring microsecond-level synchronization.
  • Decentralized assembly lines and conveyor networks exposed to moisture and dust.
  • Automotive manufacturing cells with high vibration and electromagnetic interference (EMI).
  • Test benches and measurement stations utilizing Distributed Clock technology.

Technical Specifications

Specification Parameter Value / Detail
Manufacturer Beckhoff Automation
Model Number ER1258-0002
Protocol / Fieldbus EtherCAT
Number of Inputs 8 (including 2 with timestamp configuration)
Input Connections 4 x M12 (5-pin, A-coded)
Bus Connections 2 x M8 socket (shielded, screw connection)
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 10 microseconds
Signal States (EN 61131-2, Type 3) "0" Signal: -3 to +5 V | "1" Signal: 11 to 30 V
Distributed Clocks Yes (Precision < 100 ns, Resolution 1 ns on Channel 0/1)
Current Consumption (from US) 120 mA (excluding sensor load)
Power Ports Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Electrical Isolation 500 V RMS
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Ingress Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Housing Material Zinc die-cast
Net Weight 265 g
Shipping Weight (Calculated) 2.0 kg (including secure industrial packaging)

Connections and Interfaces

Connector Port Type Typical Pin Assignment & Function
Input Channels 0 to 7 4 x M12 (2 channels per port) Pin 1: +24 V DC sensor supply; Pin 2: Input B; Pin 3: GND; Pin 4: Input A; Pin 5: FE (Functional Earth).
EtherCAT Input M8 female, 4-pin, shielded Pin 1: Tx+; Pin 2: Rx+; Pin 3: Rx-; Pin 4: Tx-. Screw-type shielding connection.
Power Supply Feed M8 male, 4-pin Pin 1: +24 V DC control voltage (US); Pin 2: +24 V DC peripheral voltage (UP); Pin 3: GNDS; Pin 4: GNDP.

Empirical Engineering Insights

Alternative Models & Compatibility

The zinc-cast ER1258-0002 serves as a highly rugged alternative to the plastic-housing EP1258-0002. They share identical functional parameters and TwinCAT XML (ESI) profiles. Ensure that TwinCAT 3 (Build 4020 or higher) is implemented to fully utilize the sub-microsecond Distributed Clock (DC) diagnostics and synchronization performance of the ER1258-0002.

Application Pitfalls & Engineering Notes

To prevent timing inaccuracies on the high-speed timestamp inputs (channels 0 and 1), avoid using sensors with switching delays greater than 5 microseconds. Standard proximity sensors often introduce an inherent delay that compromises the nanosecond synchronization capability of the hardware. Additionally, ensure the sensor supply draw does not exceed the integrated 0.5 A limit to avoid triggering the internal electronic short-circuit protection.

Commissioning & Wiring Tips

Always utilize shielded M8 fieldbus cables to connect the EtherCAT ports. The screw-type shielding on the zinc housing must establish continuous metallic contact with the cable shield to minimize electromagnetic noise on high-frequency signals. Unused M12 and M8 connections must be sealed using IP67 protective caps to prevent humidity ingress and preserve environmental ratings.

Installation Guidelines

CRITICAL WARNING: De-energize all primary control and peripheral power supplies (US and UP) before mounting or connecting the module. Failure to isolate power lines can result in electrical shock, critical hardware damage, or unpredictable machine behavior. Ensure ground potential (FE) is established via the mounting holes.
  1. 1

    Mount the zinc die-cast housing onto a flat, grounded metal surface using two M3 screws through the 3.5 mm diameter mounting holes. Torque the mounting screws to 0.8 Nm.

  2. 2

    Secure the incoming and outgoing EtherCAT lines to the M8 sockets. Ensure the screw collar is fully tightened to maintain the IP67 sealing integrity.

  3. 3

    Connect the 24 V DC power supply lines to the 4-pin M8 feed interface, monitoring current limits to prevent overloading downstream units.

  4. 4

    Attach digital inputs to the M12 sockets using A-coded cables. Configure input filters and distributed clock variables within the TwinCAT system manager.

Loading product navigation…

What is the difference between Beckhoff ER1258-0002 and EP1258-0002?

The ER series features a zinc die-cast housing designed for high mechanical loads and aggressive environments, whereas the EP series is housed in plastic. Electrical functions, signal processing, and TwinCAT parameters are identical.

How do the timestamp inputs on channels 0 and 1 work?

Channels 0 and 1 utilize Distributed Clocks (DC) to log the exact time of state transitions with a resolution of 1 ns and a precision of 10 ns. This data is transmitted to the master controller within the cyclic EtherCAT frame.

What is the maximum sensor supply current for this module?

The sensor supply provides a maximum cumulative current of 0.5 A across all ports. It is fully short-circuit proof, shutting down automatically when the limit is exceeded.

Does the ER1258-0002 support both NPN and PNP sensors?

No, the inputs are designed as positive-switching (PNP) inputs conforming to EN 61131-2 Type 1 and Type 3 specifications.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...