1 از 1

Beckhoff IP2300-B310 Fieldbus Box 8-Channel Digital I/O Module

Beckhoff IP2300-B310 Fieldbus Box 8-Channel Digital I/O Module

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: IP2300-B310

  • کشور سازنده:آلمان

  • نوع محصول: Fieldbus I/O Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 2000g

  • ابعاد: 126 mm x 30 mm x 26.5 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Decentralized automation tasks in harsh environments are directly addressed by the Beckhoff IP2300-B310, an IP67-rated Fieldbus Box designed to bridge field sensors and actuators directly with a PROFIBUS DP network without requiring a protective control cabinet. This space-saving module integrates four digital inputs featuring a fixed 3 ms filter alongside four short-circuit-proof digital outputs rated at 0.5 A per channel. Utilizing robust M8 circular connectors, the device minimizes cabling overhead, isolates network noise, and provides local diagnostic feedback via dedicated status LEDs for seamless diagnostics on the factory floor.

Features

  • Direct Machine Mounting: IP67-rated enclosure permits cabinet-free deployment, lowering thermal loads within main enclosures and optimizing cable runs.
  • Robust Fieldbus Connectivity: Embedded PROFIBUS DP interface supporting transmission speeds up to 12 Mbaud with automatic baud rate detection.
  • Comprehensive Digital I/O: Built with 4 digital inputs (24 V DC, 3 ms filter) and 4 digital outputs (24 V DC, 0.5 A load capacity).
  • Enhanced Circuit Protection: Output stages are short-circuit and overload protected, ensuring resilient field operations during actuator failures.
  • M8 Connector Interface: High-density, screw-lock M8 connections guarantee mechanical stability in high-vibration machinery.

Applications

  • Decentralized material handling and heavy conveyor systems.
  • Robotic end-of-arm tooling and end-effector sensor consolidation.
  • Pneumatic valve terminal control in automotive assembly areas.
  • Packaging machinery requiring distributed IP67-rated I/O architectures.

Technical Specifications

Manufacturer Beckhoff
Model Reference IP2300-B310
Product Series Fieldbus Box (IPxxxx Series)
Fieldbus Protocol PROFIBUS DP (up to 12 Mbaud)
Digital Inputs 4 channels, 24 V DC (nominal)
Input Filter Delay 3.0 ms
Digital Outputs 4 channels, 24 V DC, short-circuit proof
Max. Output Current 0.5 A per channel (2.0 A total module load)
Connection Style M8 screw-type connectors for digital channels
Control Voltage 24 V DC (-15% / +20%)
Current Consumption Approx. 40 mA from control voltage + sensor load
Protection Class IP67 (when all connection ports are sealed)
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Shipping Weight (Calculated) 0.35 kg (excluding outer shipping carton)
Package Dimensions (Calculated) 126 mm x 30 mm x 26.5 mm

Connections and Interfaces

M8 Port Pin Input Function / Assignment Output Function / Assignment
Pin 1 +24 V DC sensor supply (Us) Not connected (NC) / Reserve
Pin 3 0 V Ground (GNDs) 0 V Ground (GNDp)
Pin 4 Digital Input Signal (DI1 to DI4) Digital Output Signal (DO1 to DO4)

Alternative Models & Compatibility

This unit serves as a standard Profibus I/O module. When transitioning from older IP2300 hardware revisions, confirm the rotary address switch behavior matches your master configuration. If moving to industrial Ethernet architectures like EtherCAT, direct equivalents are available within the Beckhoff EP2308-0001 EtherCAT Box series, which features a similar I/O density and M8 form factor.

Application Pitfalls & Engineering Notes

When switching highly inductive DC loads (such as heavy pneumatic solenoids or magnetic brakes), flyback currents can degrade the internal output switches over time. While the digital outputs are electronically protected, deploying an external flyback diode directly at the inductive load terminals is recommended to maximize hardware longevity. Additionally, avoid exceeding the maximum group limit of 2.0 A total output current across all active output channels to prevent thermal shutdown of the internal driver IC.

Commissioning & Wiring Tips

The PROFIBUS DP address must be defined manually using the two decimal rotary switches protected beneath the clear threaded cap on the front of the module. To ensure the IP67 seal rating remains valid, verify that the clear cap is tightened to its proper torque specification (0.6 Nm) and that any unused M8 ports are securely sealed using standard IP67-rated protective plugs.

Installation Guidelines

CRITICAL WARNING

Isolate all power sources supplying the host control panel and field equipment before beginning physical mounting or wiring of this fieldbus module. Dangerous electrical shock risks, short-circuits, and unexpected actuator triggering may occur if connections are modified while power is active.

1

Securely mount the fieldbus box to a flat, rigid machine surface using two M4 bolts through the pre-cast mounting holes. Ensure the surface is free from sharp vibration sources.

2

Configure the desired PROFIBUS address (from 1 to 99) via the integrated rotary switches before connecting power or fieldbus cables.

3

Connect the incoming fieldbus cable to the designated PROFIBUS interface and terminate the line if the module sits at the physical end of the bus trunk.

4

Attach the M8 I/O cables, ensuring the locking collars are fully tightened to maintain the IP67 water and dust seal. Cap any unused channels immediately.

Loading product navigation…

How do you set the PROFIBUS station address on this module?

The PROFIBUS address is defined manually using two decimal rotary switches positioned beneath the protective clear cap on the front of the enclosure. The addresses range from 1 to 99.

What is the physical connection type for the I/O channels?

All eight digital input and output channels interface through standard screw-locking M8 circular connectors, offering IP67 protection when properly tightened.

What are the output protection ratings for the digital outputs?

Each digital output is individually protected against short circuits and thermal overload. The maximum continuous current per channel is 0.5 Amps, with a collective module limit of 2.0 Amps.

Can this unit function in environments exposed to moisture and dust?

Yes, when all ports are mated with IP67-compliant M8 cables or sealed with protective caps, the entire housing is rated to IP67, preventing dust and moisture ingress.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...