Mitsubishi Electric AJ65BT-64RD3 CC-Link Temperature Input Unit

Mitsubishi Electric AJ65BT-64RD3 CC-Link Temperature Input Unit

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Mitsubishi Electric

  • شماره محصول: AJ65BT-64RD3

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: RTD Input Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 1400g

  • ابعاد: 65 mm x 151.9 mm x 63 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

For highly precise thermal monitoring within automated industrial environments, the AJ65BT-64RD3 serves as an industrial-grade platinum resistance temperature detector (RTD) input module. This remote device station interfaces directly with CC-Link networks, allowing seamless integration of temperature sensor telemetry into central PLC and DCS systems.

The module supports four independent 3-wire RTD input channels compatible with standard Pt100 and JPt100 sensors. It translates raw analog sensor signals into either 16-bit or high-resolution 32-bit signed binary values, ensuring precise digital conversion. Electrical isolation via internal photocouplers isolates the sensor input circuitry from the CC-Link communication line, safeguarding the network from common-mode voltage spikes and electromagnetic noise.

Features

  • Supports up to 4 independent 3-wire RTD channels (Pt100 and JPt100 compatibility).
  • Fast conversion speed of 40 ms per channel for real-time monitoring.
  • Flexible digital output configuration with 16-bit or 32-bit signed binary modes.
  • High-integrity photocoupler isolation between the sensor inputs and the CC-Link transmission system.
  • Removable 2-piece terminal block interfaces (7-point and 27-point M3.5 screw terminals) to simplify field wiring and module replacement.

Applications

  • Thermal monitoring of industrial furnaces and ovens.
  • Chemical and petrochemical process temperature tracking.
  • HVAC, refrigeration, and cooling system management.
  • Power generation plant turbine and bearing temperature diagnostics.

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model AJ65BT-64RD3
Module Type CC-Link RTD Temperature Input Unit
Number of Channels 4
Compatible Sensors Pt100, JPt100 (3-wire type)
Measurement Range -180 to 600 degC (both Pt100 and JPt100)
Resolution 0.025 degC
Sensor Output Current 1 mA
Accuracy (25 degC +/- 5 degC) +/- 0.1% of full scale
Accuracy (0 to 55 degC) +/- 0.25% of full scale
Conversion Speed 40 ms / channel
CC-Link Station Type Remote Device Station (Ver.1, occupies 4 stations)
Isolation Method Photocoupler isolation (between inputs and CC-Link line; non-isolated between channels)
Withstand Voltage 500 VAC for 1 minute (between power, communication, input, and ground terminals)
Insulation Resistance 10 MOhm or more (at 500 VDC)
Power Requirements 24 VDC (18 to 30 VDC allowable), 0.17 A
Terminal Connection Type 7-point terminal block (M3.5 screws) for power and CC-Link; 27-point terminal block (M3.5 screws) for sensor I/O
Operating Temperature 0 to 55 degC
Storage Temperature -20 to 75 degC
Ambient Humidity 10 to 90% RH (non-condensing)
Dimensions (H x W x D) 65 mm x 151.9 mm x 63 mm
Weight 0.38 kg (Shipping Weight: 1.4 kg)

Installation Guidelines

  • Install the module inside a clean, dust-free industrial control cabinet rated for IP54 or higher.
  • Ensure the system is completely powered down before connecting or disconnecting the CC-Link cable and RTD wiring.
  • Utilize CC-Link dedicated cabling to ensure signal integrity across the fieldbus network.
  • Ground the shielded wire of the CC-Link cable and connect the module's ground terminal to a low-impedance ground point.
  • Maintain a minimum clearance around the module to allow proper heat dissipation.
Loading product navigation…

What sensor types are compatible with the AJ65BT-64RD3?

The module is compatible with 3-wire Pt100 and JPt100 platinum resistance temperature detectors (RTDs).

What is the conversion rate of this temperature input unit?

The AJ65BT-64RD3 features a fast conversion speed of 40 milliseconds per channel.

Does the AJ65BT-64RD3 provide isolation between individual channels?

No, while there is photocoupler isolation between the sensor inputs and the CC-Link communication/power line, individual channels are not isolated from each other.

What terminal block type is used for wiring connections?

The unit features removable 2-piece terminal blocks with M3.5 screws: a 7-point block for power and communication, and a 27-point block for RTD channel connections.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...