1 of 3

Module de sortie numérique Allen-Bradley 1756-OB16IS

Module de sortie numérique Allen-Bradley 1756-OB16IS

Il ne reste que 6 article(s) en stock
  • Fabricant : Allen-Bradley

  • N° de produit : 1756-OB16IS

  • Pays d'origine :États-Unis

  • Type de produit : Module de Sortie Numérique

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 200g

  • Dimensions : 3,5 cm x 14,2 cm x 14,5 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

The 1756-OB16IS is a digital output execution component built for the ControlLogix system configuration. It functions within a nominal 12/24V DC voltage envelope, featuring 16 channels that are isolated individual points designed to secure downstream circuitry against cross-signal disturbance and transient spikes. This module integrates 8 scheduled output points designed to enable precise synchronization matching coordinated machine sequences with reference to the Coordinated System Time. It installs inside standard control slots, interfacing with industrial field loads via specified removable termination assemblies to provide deterministic actuation and steady processing states under multiple manufacturing control configurations.

Features

  • Incorporates 16 isolated output channels providing basic insulation between output points and backplane circuits.
  • Features 8 scheduled outputs allowing time-stamped task performance linked directly with coordinated control architecture.
  • Provides sinking or sourcing load matching with an execution range spanning 10V DC to 30V DC field operations.
  • Delivers continuous visual verification of independent output channel execution states and module hardware health.
  • Supports electronic, software-configurable keying options to enforce accurate hardware module matching upon slot replacement.

Applications

  • High-speed sorting and discrete tracking machinery requiring timed sequence control.
  • Solenoid valve switching loops and isolated pilot relay driving circuits.
  • Multi-zone industrial heating elements requiring synchronized control pulses.

Technical Specifications

Parameter Specification
Outputs 16 individually isolated, 8 scheduled
Pilot Duty 2 A (DC-13SQ)
Voltage Category 12/24V DC sink/source
Operating Voltage Range 10...30V DC
Output Delay Time (Off to On) 1 ms max
Output Delay Time (On to Off) 2 ms max
Current Draw @ 5.1V 350 mA
Current Draw @ 24V 2.5 mA
Total Backplane Power 1.8 W
Power Dissipation, Max 3.6 W @ 60 degC (140 degF)
Thermal Dissipation 12.28 BTU/hr
Off-State Leakage Current Per Point, Max 0.5 mA per point
On-State Voltage Drop, Max 1.2V DC @ 2 A
Current Per Point, Max 2 A @ 30 degC (86 degF), 1 A @ 60 degC (140 degF) (linear derating)
Current Per Module, Max 8 A @ 30 degC (86 degF), 4 A @ 60 degC (140 degF) (linear derating)
Surge Current Per Point 4 A for 10 ms per point, repeatable every 2 s
Load Current, Min 1 mA per point
Scheduled Outputs Synchronization Within 16.7 s max, reference to the Coordinated System Time
States in Fault Mode Per Point Hold last state, On or Off (Off is default)
States in Program Mode Per Point Hold last state, On or Off (Off is default)
Isolation Voltage 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Module Keying Electronic, software configurable
Removable Terminal Block 1756-TBCH, 1756-TBS6H
RTB Keying User-defined mechanical
Slot Width 1
Wire Category 1
Wire Type Copper
Enclosure Type None (open-style)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 2 g @ 10...500 Hz
Shock, Operating 30 g
Shock, Nonoperating 50 g
Emissions IEC 61000-6-4

Installation Guidelines

  • Ensure conductor routing follows specified guidelines for Wire Category 1 paths to reduce crosstalk with high-voltage power components.
  • Use only approved ControlLogix Removable Terminal Blocks, specifically models 1756-TBCH or 1756-TBS6H, to wire external field outputs.
  • Set the software-based electronic keying attributes accurately within the project configuration to prevent mismatched module replacement errors.
  • Apply appropriate current derating factors when operating ambient conditions rise, limiting per-point current to 1 A when reaching 60 degC.
  • Mount the open-style chassis assembly inside an enclosure that offers appropriate protective barrier sealing against environmental particulates.

Compliance and Certifications

  • cULus Listed Industrial Control Equipment (UL File E65584)
  • cULus Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)
  • CE (European Union 2014/30/EU EMC Directive, EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; 2014/35/EU LVD Directive, EN 61131-2)
  • RCM (Australian Radiocommunications Act, EN 61000-6-4)
  • ATEX (European Union 2014/34/EU ATEX Directive, EN IEC 60079-0, EN IEC 60079-7, II 3 G Ex ec IIC T4 Gc, UL22ATEX2820X)
  • IECEx (IEC 60079-0, IEC 60079-7, II 3 G Ex ec IIC T4 Gc, IECEx UL 22.0065X)
  • UKex (UKEX Regulation 2016 No. 1107, Equipment protection by increased safety "e", UL22UKEX2602X, Zone 2 classification)
  • KC (Korean Registration of Broadcasting and Communications Equipment, Article 58-2 of Radio Waves Act)
  • UKCA (2016 No. 1091, 2016 No. 1101, 2016 No. 1107, 2012 No. 3032)
  • Morocco (Arrête ministériel n° 6404-15)
  • CCC (2020122309111998, CNCA-C23-01 CCC Implementation Rule Explosion-Proof Electrical Products)
Loading product navigation…

Quelle est la tension d'isolement continue fournie par l'appareil ?

L'appareil offre une tension d'isolement continue de 250 V grâce à une isolation de base entre les sorties et le fond de panier ainsi qu'entre les sorties elles-mêmes.

Comment les conditions environnementales affectent-elles le courant maximal autorisé par point ?

Le courant maximal par point est de 2 A lorsque l'appareil fonctionne à une température ambiante allant jusqu'à 30 °C, puis il diminue linéairement jusqu'à 1 A lorsque la température atteint 60 °C.

Que se passe-t-il aux sorties lorsque le contrôleur passe en mode Défaut ou Programme ?

Chaque canal de sortie peut être configuré pour maintenir son dernier état, s'allumer ou s'éteindre. La configuration par défaut impose un état éteint pour les deux modes.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Noir
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...