Designed to act as a high-reliability operator interface directly within control cabinets, the Beckhoff CP6733-0000-0050 integrates medium-scale computing performance with a robust touchscreen display. This built-in industrial panel PC is engineered to withstand demanding factory environments, combining a durable IP65-rated front panel with efficient passive cooling. Leveraging the Intel Atom processor architecture, the unit delivers consistent execution for TwinCAT-based control systems and local visualization tasks while maintaining low power consumption and a compact installation depth.

Key Features

  • Industrial Display: High-resolution industrial-grade touch screen with options for functional front laminates.
  • Durable Construction: Robust front-side IP65 ingress protection paired with a sheet-steel rear cover.
  • Toolless Integration: Utilizes specialized pull-out clamping levers for quick and secure mounting without loose hardware.
  • Broad Connectivity: Equipped with dual integrated Gigabit Ethernet interfaces and multiple USB ports for peripheral integration.
  • Flexible Storage Options: Supports CFast card configurations alongside traditional storage expansion slots.

Applications

  • Machine-level Human-Machine Interface (HMI) in automated manufacturing environments.
  • Assembly line and packaging machine visualization and control.
  • Built-in cabinet terminals for material handling and logistics monitoring systems.
  • Distributed control nodes in process engineering applications.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model/Part Number CP6733-0000-0050
Device Type Economy Built-in Panel PC
Processor Option Intel Atom E38xx series (1.46 GHz Single-Core to 1.91 GHz Quad-Core compatible)
System Memory 2 GB DDR3L RAM (expandable ex factory up to 8 GB)
Ethernet Interfaces 2 x 100/1000BASE-T on-board ports
USB Ports 4 x USB 2.0 ports
Display Output 1 x DVI-D port
Storage Slots CFast slots / 2.5-inch SSD or HDD mounting options
Operating Voltage 24 V DC
Protection Rating Front side IP65, Rear side IP20
Operating Temperature 0 to 55 degC
Housing Material Aluminum front, sheet-steel rear cover
Country of Origin Germany
Shipping Weight (Calculated) 5.0 kg
Package Dimensions (Calculated) 450 x 400 x 180 mm

Connections and Interfaces

Interface Type Connection Specification / Function
Power Input 3-pin screw-terminal power plug for 24 V DC supply and grounding connection
LAN 1 / LAN 2 RJ45 connectors for independent 100/1000BASE-T Ethernet channels
USB Ports 4 x Type-A USB 2.0 connectors for external peripherals and keyboard tools
DVI Connection 1 x DVI-D port for connecting a secondary digital display clone or desktop

Alternative Models & Compatibility

The CP6733-0000-0050 belongs to the modular CP67xx family. When swapping within this series, note that processing capability dictates the TwinCAT performance level (TC2/TC3 Performance Level 40 for single-core or Level 50 for quad-core chips). Always match the operating system (such as Windows Embedded Compact 7 or Windows 10 IoT) to the runtime configuration of your control project. Ensure firmware and TwinCAT builds are verified before migrating a physical unit.

Application Pitfalls & Engineering Notes

To ensure long-term thermal stability, the panel’s rear ventilation (IP20-rated) must remain unobstructed inside the enclosure. If the ambient temperature inside the control cabinet exceeds 50 degC, active circulation fans should be introduced to prevent automatic CPU thermal throttling. Avoid exposing the front touchscreen to continuous, direct high-pressure chemical washdowns, as this can degrade the front sealing gasket over extended operating lifecycles.

Commissioning & Wiring Tips

Always route the 24 V DC power cables separately from high-voltage variable frequency drive (VFD) output cables to minimize electromagnetic interference. Ground the chassis using the integrated grounding lug located directly next to the power plug. When formatting new CFast flash cards, ensure you write a bootable Beckhoff partition image matching the native OS of the target runtime, otherwise the system will fail to boot past the BIOS screen.

Installation Guidelines

CRITICAL WARNING: Prior to cabinet installation or modification, ensure all incoming 24 V DC power feeds are completely de-energized and locked out. Confirm that the physical cabinet cutout is clear of burrs to prevent tearing the front IP65 sealing gasket during mounting.
1
Verify that the panel cutout dimensions precisely match the specification sheet for the CP6733 chassis series.
2
Carefully insert the panel PC from the front of the cutout, ensuring the integrated perimeter seal lies completely flat against the cabinet door.
3
Engage the pull-out clamping levers from the rear of the PC, tightening them uniformly until the front seal is compressed firmly against the cabinet wall.
4
Connect the functional ground wire to the chassis grounding point, insert the 24 V DC supply terminal block, and secure the communication connections.
Loading product navigation…

What is the ingress protection rating of the CP6733-0000-0050?

The front side of the Panel PC features an IP65 protection rating when correctly installed in a panel cutout, while the rear side is rated IP20 and relies on passive ambient ventilation.

Can this panel PC be used with TwinCAT control platforms?

Yes, the CP6733 series fully supports TwinCAT 2 and TwinCAT 3 runtime environments, with a hardware performance category rating of Level 40 or 50 depending on the integrated processor configuration.

What power input is required for standard operation?

The unit operates on a standard 24 V DC power supply. An external uninterruptible power supply (UPS) is highly recommended to protect critical system memory configurations.

How do you mount this device into an enclosure?

It is equipped with integrated pull-out clamping levers that latch directly into the side walls of a standard panel cutout, allowing secure mounting without requiring loose parts.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...