The EL2809 (EL2809) is a high-density 16-channel digital output terminal from the Beckhoff EL series, designed for the efficient switching of industrial actuators within an EtherCAT terminal network. This compact module provides 16 individual digital outputs, allowing for the direct control of ohmic, inductive, or lamp loads in space-constrained control panels. Engineered to minimize downtime, the EL2809 integrates robust diagnostic and protective features, including short-circuit proofing and reverse voltage protection, ensuring system reliability in demanding factory automation and process control environments.
Technical Configuration
The EL2809 utilizes the high-speed EtherCAT E-bus for communication, consuming approximately 140 mA. Each of the 16 channels is capable of switching currents up to 0.5 A, making it versatile for driving solenoid valves, relays, or indicator lamps. To ensure operational safety, the module incorporates comprehensive electrical isolation up to 500 V between the E-bus and field potential. Furthermore, the terminal is designed to handle breaking energy up to 150 mJ per channel, providing protection against inductive flyback during the switching of coils or inductive loads.
Technical Specifications
Feature
Specification
Model
EL2809
Brand
BECKHOFF
Origin
Germany
Shipping Weight
1.5 kg
Number of Channels
16
Output Current
0.5 A per channel
Short Circuit Protection
Yes (typ. < 2 A)
Breaking Energy
< 150 mJ per channel
Electrical Isolation
500 V
Current Consumption
140 mA (E-bus)
FAQs
Is the EL2809 compatible with inductive loads like solenoid valves?
Yes, the terminal is specifically designed to support ohmic, inductive, and lamp loads. It includes features to handle the energy released when switching off inductive components, up to 150 mJ per channel.
What level of protection does the EL2809 provide against wiring errors?
The terminal features integrated reverse voltage protection and is short-circuit proof on every channel, which prevents permanent hardware damage in the event of field-side wiring faults.
Does this terminal require additional power supply modules?
The E-bus is powered via the EtherCAT network; however, the field power for the 16 outputs must be supplied through the designated power contacts on the terminal to drive the connected actuators.
Installation and Operational Recommendations
Inductive Load Management: When switching large inductive loads that exceed the 150 mJ breaking energy rating, ensure external flyback diodes or suppression circuits are implemented to prevent premature wear on the terminal’s output drivers.
Wiring Density: Due to the high density of 16 channels, ensure that field cabling is neatly organized and properly labeled. Use ferrules on all flexible conductors to ensure a secure, low-resistance connection within the spring-clamp terminals.
Thermal Considerations: In applications where all 16 channels are active simultaneously at high current loads (approaching 0.5 A per channel), ensure adequate ventilation within the control cabinet. Continuous operation at maximum current capacity generates heat, and ambient temperatures should be strictly maintained within the specified operating range to maximize component longevity.
Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.
Retours et garantie
Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.
Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).
Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel
Politique de remboursement et de retour
.
Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...
Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...
Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...
Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...
Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...
Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...
Choisir une sélection entraîne un rechargement complet de la page.