1 of 1

IE3202 | BECKHOFF | Boîtier d'extension

IE3202 | BECKHOFF | Boîtier d'extension

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : IE3202

  • Pays d'origine :Allemagne

  • Type de produit : Boîtier d'extension

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for precise decentralized temperature acquisition, the BECKHOFF IE3202 Fieldbus Box extension module interfaces directly with resistive sensors in rugged, industrial environments. This IP67-rated analog input device facilitates the direct connection of up to four resistance thermometers without requiring protective control cabinets. By digitizing signals close to the physical process, it reduces noise susceptibility and cabling complexity.

The IE3202 supports a broad spectrum of RTD configurations, including standard Pt100, Pt200, Pt500, and Pt1000 sensors, alongside Ni100, Ni120, and Ni1000 variants. It also accommodates direct resistance measurements, such as those from potentiometers. Each of the four channels utilizes screw-type M12 connectors that can be wired in 2-wire, 3-wire, or 4-wire configurations (preset to 4-wire) to compensate for cable resistance errors and optimize measurement precision.

Operating as an IP-Link extension module, this device integrates seamlessly with Beckhoff Coupler Box modules, transferring digitized process data over high-speed IP-Link communication channels. The robust housing, high-resolution digitization, and configurable filtering capabilities make it an ideal choice for challenging distributed control architectures.

Features

  • Four independent analog inputs dedicated to RTD and resistance measurements.
  • Flexible M12 screw-type connections supporting 2-, 3-, and 4-wire configurations.
  • Compatible with a comprehensive range of platinum (Pt) and nickel (Ni) sensors.
  • High-resolution data acquisition at 0.1 degC per digit for sensitive thermal monitoring.
  • Configurable conversion times ranging from a standard 250 ms down to 65 ms.
  • Five configurable digital input filter variations for advanced noise rejection.
  • IP-Link interface for fast, reliable data exchange with fieldbus couplers.
  • Heavy-duty IP65/66/67 protection rating for direct mounting in harsh industrial zones.

Applications

  • Decentralized process temperature tracking in plant engineering and machine construction.
  • Thermal monitoring of motors, bearings, and critical mechanical assemblies.
  • Food processing and washdown-heavy environments requiring direct-to-machine installation.
  • HVAC, chemical processing, and environmental monitoring systems.

Technical Specifications

ManufacturerPart Number / ModelNumber of InputsConnection MethodSensor TypesMeasuring RangeResolutionMeasurement Error / UncertaintyConversion TimeNominal VoltageMeasuring CurrentInput FilterSensor SupplyCurrent Consumption from USPower Supply ConnectionBit Width in Process ImageElectrical IsolationOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection RatingInstallation PositionWeight
BECKHOFF
IE3202
4
Screw-type M12 for 2-, 3-, and 4-wire connections (preset: 4-wire)
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g., potentiometer)
-250 to +850 degC (Pt sensors); -60 to +250 degC (Ni sensors)
0.1 degC per digit
less than ±1 degC
Approx. 250 ms, configurable down to 65 ms
24 V DC (-15 % / +20 %)
typ. 0.5 mA
5 variations, configurable
Derived from control voltage US
40 mA (excluding sensor current)
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Input: 4 x 16-bit data (4 x 8-bit control/status optional)
Channels/control voltage: 500 V; Between channels: None; Control voltage/fieldbus: Yes, via IP-Link
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65/66/67 (conforms to EN 60529)
Variable
2.0 kg

Connections and Interfaces

Power FeedPower DownstreamAnalog Inputs 1 - 4
Connection Point Connector Type Functional Assignment
M8 Male, 4-pin Control voltage US input
M8 Female, 4-pin Loop-through control voltage US to subsequent modules
M12 Female, 5-pin RTD sensor connection (supporting 2-, 3-, or 4-wire layouts)

Installation Guidelines

  • Mounting: Mount the unit directly onto a flat, vibration-resistant surface using appropriate fastening screws. Ensure sufficient clearance for connecting and disconnecting cables.
  • Shielding & Grounding: To minimize electromagnetic interference, use shielded sensor cables. Connect the cable shields to the metal M12 connector housings wherever possible.
  • Environmental Protection: To maintain the IP65/66/67 seal, tighten all M12 and M8 connectors to their specified torque limits. Seal any unused connection ports with industrial-grade protective caps.
  • Cabling: Maintain separation between sensor input lines and high-power AC power cables or variable frequency drive outputs to prevent noise coupling.

Compliance and Certifications

  • CE: European Conformity
  • UL: Underwriters Laboratories Listed
Loading product navigation…

Which temperature sensor types are compatible with the Beckhoff IE3202?

The IE3202 is compatible with several RTD types, including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, and Ni1000. It also supports general resistance and potentiometer measurements.

Does the IE3202 support 3-wire RTD configurations?

Yes, the M12 screw-type terminals can be wired for 2-wire, 3-wire, or 4-wire sensors. The device is preset for 4-wire operation out of the box.

What is the ingress protection rating of the IE3202 Fieldbus Box?

It is rated at IP65, IP66, and IP67, making it dust-tight and highly resistant to water jets and temporary submersion. This allows direct installation on machines without control cabinets.

How does the IE3202 transfer its measurement data to the main PLC system?

The IE3202 acts as an extension module that connects to a master Fieldbus Box (Coupler Box) via the high-speed fiber-optic IP-Link interface, which then bridges the data to the main fieldbus protocol.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...