Description

Designed for decentralized control architectures, the Beckhoff IP2042-B518 operates as a high-performance Fieldbus Box distributing 8 digital output channels directly in rugged field environments via a CANopen interface. This robust device allows the direct connection of 24 V DC actuators, such as solenoid valves, contactors, and indicators, without requiring an additional protective terminal enclosure. Featuring integrated T-connector bus interfaces and M12 output connections, it offers an exceptionally high output capacity of up to 2 A per channel (12 A cumulative total), ensuring reliable power distribution in high-load industrial applications.

Features

  • High Current Output: Employs 8 digital channels handling 2 A each, individually protected against short circuits.
  • Integrated T-Connector: Simplifies network trunk line wiring with a pre-integrated M12 daisy-chain interface.
  • Automatic Network Adaptation: Instantly detects communication speeds from 10 kbaud up to 1 Mbaud on the CANopen network.
  • Environmentally Sealed Housing: Standard XXL polyamide casing with IP65, IP66, and IP67 protection ratings.
  • Advanced Diagnostics: Built-in variable mapping, emergency objects, and Node/Life Guarding options for reliable network status tracking.

Applications

  • Decentralized packaging machine lines requiring direct, cabinet-free mounting.
  • Automotive assembly automation with high-density localized actuator clusters.
  • Heavy material handling and conveyor automation systems.
  • Pneumatic valve manifold control and distributed solenoid piloting.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Reference IP2042-B518
Output Count 8 digital outputs
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 2 A per channel (short-circuit proof)
Aggregate Output Limit Max. 12 A (Ch 0-3: sum 4 A | Ch 4-5: sum 4 A | Ch 6-7: sum 4 A)
Fieldbus System CANopen (up to 16 Rx / 16 Tx PDOs)
Baud Rates 10 kbaud to 1 Mbaud (automatic auto-detection)
Control Voltage Current Draw 45 mA + sensor current load (max 0.5 A)
Electrical Isolation Control voltage to fieldbus: 500 V
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Environmental Protection IP65/66/67 (conforms to EN 60529)
Housing Material Polyamide PA6
Device Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector / Terminal Type Pin Number Function / Signal Assignment
CANopen Bus Interface (M12) Pin 1 Shield / Functional Earth
Pin 2 V+ (Bus Power, optional)
Pin 3 CAN Ground (GND)
Pin 4 CAN High (CAN_H)
Pin 5 CAN Low (CAN_L)
Power Supply Inlet (M8 Feed) Pin 1 Control Voltage +24 V DC (Us)
Pin 2 Load Voltage +24 V DC (Up)
Pin 3 GND Us
Pin 4 GND Up

Alternative Models & Compatibility

The IP2042-B518 is fully compatible with standard Beckhoff CANopen structures. It serves as a direct drop-in replacement for equivalent legacy IP2042 modules using the -B510 and -B518 variants. Users upgrading or replacing modules must ensure that the master PLC controller possesses the correct EDS file to support the extended diagnostics and flexible variable mapping capabilities of the -B518 series.

Application Pitfalls & Engineering Notes

Pay close attention to internal power budget grouping rules. While individual channels are short-circuit protected and rated for 2 A, physical thermal constraints within the housing limit aggregate current draws. Specifically, channels 0-3 must not exceed a combined total of 4 A; channels 4-5 must not exceed 4 A; and channels 6-7 are restricted to 4 A. Exceeding these thermal grouped limits can cause regional shut-down or local safety tripping.

Commissioning & Wiring Tips

To optimize signaling efficiency on long CANopen network segments, always utilize properly shielded, twisted-pair copper cabling specifically designed for industrial CAN networks. Additionally, a 120-ohm bus termination resistor must be installed on the unused M12 port if this specific module constitutes the physically final node on the CANopen network bus trunk line.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources (control voltage Us and load voltage Up) prior to mechanical installation, cable connection, or hardware service. Failure to de-energize circuits may cause localized arc faults, damage internal solid-state components, and compromise the network interface.

1
Position the module on a flat mounting surface and align the physical fixing points. Securely mount using two 3.5 mm diameter M3 screws. Do not over-torque.
2
Connect the incoming CANopen network feed line to the integrated M12 plug interface, and loop output networks using the integrated M12 socket.
3
Attach the M8 supply cabling, verifying separate wiring paths for the control voltage (Us) and output load voltage (Up). Tighten the lock rings to ensure an IP67 liquid-tight seal.
Loading product navigation…

What are the channel group current limits for the IP2042-B518?

While each channel supports up to 2 A individually, the module has sum limits: channels 0 to 3 are capped at 4 A total, channels 4 and 5 at 4 A, and channels 6 and 7 at 4 A. The overall maximum module current is 12 A.

Does this Fieldbus Box require a separate CANopen termination resistor?

Yes. If the IP2042-B518 is the last physical device on the CANopen bus trunk, a matching 120-ohm termination resistor must be installed on the outgoing M12 bus connection.

How do I configure the baud rate on this module?

The module features automatic baud rate detection ranging from 10 kbaud up to 1 Mbaud, aligning itself with the active master on the network automatically.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...