1 of 1

KL1889 | Beckhoff | Bornier HD Bus

KL1889 | Beckhoff | Bornier HD Bus

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : KL1889

  • Pays d'origine :Allemagne

  • Type de produit : Bornier de bus HD

  • Paiement : Virement bancaire, Western Union

  • Poids : 55g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered for high-density space conservation in control cabinets, the BECKHOFF KL1889 is a High-Density (HD) Bus Terminal featuring sixteen digital inputs in a compact 12 mm housing width. Operating with negative switching (sink) logic, this module incorporates 1-wire connection technology, allowing direct connection of sensors and signals to the process image without excessive terminal blocks. Designed for seamless integration into K-bus networks, the KL1889 enables efficient signal acquisition in restricted spaces while simplifying wiring and minimizing hardware requirements.

Features

  • Provides 16 digital inputs within a compact 12 mm mechanical footprint.
  • Utilizes negative switching (sink) logic configuration.
  • Employs 1-wire connection technology with direct plug-in connection for solid conductors.
  • Tool-free termination for solid conductors; simple spring actuation by screwdriver for stranded wires and ferrules.
  • Integrated hardware input filter (typ. 3.0 ms) to suppress line bounce and noise.
  • Complete 500 V galvanic isolation between the internal K-bus and the field potential.
  • Address-free configuration for immediate plug-and-play installation within the Bus Coupler process image.

Applications

  • Space-constrained decentralized control systems and distribution cabinets.
  • Automated assembly systems, packaging machinery, and material handling lines.
  • Sensor signal concentration in industrial process automation.
  • General manufacturing and PLC I/O expansion environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model KL1889
Connection Technology 1-wire
Specification Negative switching (sink)
Number of Inputs 16
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage 18 to 30 V
"1" Signal Voltage 0 to 7 V
Input Filter typ. 3.0 ms
Input Current typ. 3 mA
Current Consumption (K-bus) typ. 20 mA
Current Consumption (Power Contacts) typ. 4 mA + load
Electrical Isolation 500 V (K-bus to field potential)
Bit Width in Process Image 16 inputs
Conductor Connection (Solid) Direct plug-in technique (0.08 to 1.5 mm²)
Conductor Connection (Stranded) Spring actuation by screwdriver (0.25 to 1.5 mm²)
Conductor Connection (Ferrule) Spring actuation by screwdriver (0.14 to 0.75 mm²)
Weight approx. 55 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Connections and Interfaces

Connection Type Conductor Type Cross-section Range
Direct Plug-In Solid Wire 0.08 to 1.5 mm²
Screwdriver Spring Actuation Stranded Wire 0.25 to 1.5 mm²
Screwdriver Spring Actuation Ferrule 0.14 to 0.75 mm²

Installation Guidelines

  • Ensure the system power supply is completely disconnected before mounting or removing the terminal.
  • Mount the module onto a standard 35 mm DIN rail (EN 60715) with vertical or horizontal mounting orientation as required.
  • Ensure the side locking mechanism of the bus terminal engages correctly with adjacent terminals to secure reliable K-bus and power contact transmission.
  • Utilize appropriate shielding and grounding procedures for sensor lines to prevent electromagnetic interference from distorting input signals.

Compliance and Certifications

  • CE
  • UL
  • Ex
  • GL
Loading product navigation…

What is the signal logic used by the BECKHOFF KL1889?

The KL1889 uses negative switching (sink) logic with 16 digital inputs.

What type of connection technology does the KL1889 support?

The module utilizes 1-wire connection technology, allowing direct conductor routing for digital signals with minimal wiring overhead.

Does the KL1889 require software addressing during setup?

No, the KL1889 is address-free and does not require software configuration; it integrates automatically into the K-bus process image.

What are the allowed conductor types and sizes for connection?

It supports solid wire (0.08 to 1.5 mm²), stranded wire (0.25 to 1.5 mm²), and ferrules (0.14 to 0.75 mm²).

What is the IP rating of the KL1889 housing?

The KL1889 has an IP20 protection class and must be installed within an appropriate control cabinet or enclosure.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...