1 of 1

KS4434 | BECKHOFF | Bornier de bus

KS4434 | BECKHOFF | Bornier de bus

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : KS4434

  • Pays d'origine :Allemagne

  • Type de produit : Bornier de bus

  • Paiement : Virement bancaire, Western Union

  • Poids : 75g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered for precise analog automation control, the BECKHOFF KS4434 analog output terminal delivers four channels of high-resolution control signals. Operating within a standard range of -10 to +10 V, this bus terminal features single-ended circuitry designed to drive analog actuators, control valves, and speed-controlled motor drives with precision.

A defining feature of the KS series is its pluggable wiring level, enabling fast, tool-free module replacement without disrupting existing system wiring. Integrating seamlessly into the Beckhoff K-bus system, the module transmits electrically isolated signals back to the automation controller, maintaining process stability and protecting sensitive upstream components from electrical noise.

Features

  • Four single-ended analog output channels.
  • Standard bipolar voltage signal range of -10 to +10 V.
  • 12-bit analog resolution for fine control loop adjustments.
  • Pluggable connection level for swift, minimized-downtime maintenance.
  • Short-circuit proof outputs with active load protection above 5 kOhm.
  • Robust electrical isolation rated up to 500 V between K-bus and signal circuits.
  • Direct DIN rail installation with reliable double-slot side-by-side locking.

Applications

  • Industrial machinery and process control systems.
  • Variable frequency drive speed setting regulation.
  • Proportional valve control in hydraulic and pneumatic systems.
  • HVAC ventilation, damper, and actuator positioning.
  • OEM manufacturing lines and assembly automation.

Technical Specifications

System & Electrical Parameters
Manufacturer BECKHOFF
Part Number / Model KS4434
Number of Outputs 4
Signal Voltage Range -10 to +10 V
Output Load > 5 kOhm (short-circuit proof)
Output Error < +/-0.1 % (relative to full-scale value)
Resolution 12 bit
Conversion Time ~ 4 ms
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus Typ. 20 mA
Process Image Bit Width Output: 4 x 16-bit data (optional 4 x 8-bit control/status)
Current Load Power Contacts Max. 10 A
Mechanical & Environmental Data
Connection Technology Spring actuation (tension clamp)
Solid Wire Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Fine-Strand Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.075 kg
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Operating Temperature 0 to 55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20

Installation Guidelines

  • Mounting: Mount the bus terminal horizontally or vertically on a standard 35 mm DIN rail. Secure the terminal using the integrated lock mechanism.
  • Wiring: Use a flat-blade screwdriver to open the spring clamp terminal. Insert the stripped wire (9 to 10 mm stripping length) and release the clamp.
  • Shielding & Grounding: Ensure the analog signal cables are properly shielded to prevent electromagnetic interference from surrounding power circuits. Connect the shield to the ground plane closest to the entry point.
  • Pluggable Level: When servicing, slide the pluggable terminal connector out of the housing to disconnect wiring safely without terminal-by-terminal rewiring.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • DNV GL
Loading product navigation…

What is the key advantage of the BECKHOFF KS series over the standard KL series?

The KS series, including the KS4434, features a pluggable wiring level. This allows the terminal housing to be pulled out and replaced without disconnecting the field wiring, reducing maintenance time.

What signal range does the BECKHOFF KS4434 analog output terminal use?

The KS4434 outputs a bipolar voltage signal ranging from -10 V to +10 V.

Does the KS4434 require manual address configuration?

No, the KS4434 does not require manual address or hardware configuration settings; it is automatically mapped into the system's process image.

Is the analog output protected against short circuits?

Yes, the analog outputs are short-circuit proof with an active load protection recommended above 5 kOhm.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...