Beckhoff KS9570 Bus Terminal Buffer Capacitor Terminal

Description

Designed to stabilize supply voltages in highly dynamic drive systems, the **Beckhoff KS9570** buffer capacitor terminal provides reliable energy storage and overvoltage protection within the standard Bus Terminal system. This module absorbs regenerative energy generated during motor deceleration phases, protecting upstream power supplies and sensitive electronic components from overvoltage transients. Featuring a pluggable wiring level, the **KS9570 buffer capacitor** is fully compatible with all KSxxxx series Bus Terminals, allowing for rapid installation and simplified maintenance in demanding industrial environments.

Features

  • High-capacity 500 uF buffer for effective absorption of regenerative energy.
  • Integrated surge voltage protection threshold set above 56 V to safeguard field-side electronics.
  • Pluggable wiring level design for quick, tool-free terminal replacement without disconnecting field wiring.
  • Support for external braking resistor (recommended model ZB8110) with load-dependent 2-point control.
  • Robust electrical isolation of 1500 V between the K-bus and field potential.
  • Compact 12 mm housing width for optimized space utilization on standard DIN rails.

Applications

  • Dynamic motion control and servo drive systems.
  • Industrial manufacturing and packaging assembly lines.
  • Decentralized control cabinets requiring localized voltage stabilization.
  • Material handling systems with frequent start-stop and deceleration cycles.

Technical Specifications

Manufacturer Beckhoff
Part Number/Model KS9570
Nominal Voltage 50 V
Capacity 500 uF
Ripple Current (max.) 10 A @ 100 kHz
Internal Resistance < 20 mOhm @ 100 kHz
Surge Voltage Protection > 56 V
Recommended Braking Resistor ZB8110
Overvoltage Control Range +/-2 V
Braking Resistor Clock Rate Load-dependent, 2-point control
Electrical Isolation 1500 V (K-bus/field potential)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Housing Material Polycarbonate
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.065 kg

Connections and Interfaces

Connection Parameter Specification
Wiring Method Spring actuation by screwdriver
Solid Wire Connection Cross-Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Stranded Wire Connection Cross-Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Flexible Wire Connection Cross-Section 0.14 to 1.5 mm2 (AWG 26 to 16)
Stripping Length 9 to 10 mm
Current Load Power Contacts (Imax) 10 A

Installation Guidelines

  • Mounting: Mount directly onto a standard 35 mm DIN rail conforming to EN 60715. Secure using the integrated locking mechanism.
  • Side-by-Side Installation: Align adjacent terminals using the double slot and key connection system to ensure proper mechanical stability and electrical contact.
  • Wiring: Use a suitable flat-head screwdriver to actuate the tension clamp spring. Insert stripped wire (9 to 10 mm stripping length) and release the spring to secure.
  • Ventilation: Ensure adequate clearance around the terminal housing to maintain operating temperatures within the specified 0 to +55 degC range.

Compliance and Certifications

  • CE
Loading product navigation…

What is the primary function of the Beckhoff KS9570?

The Beckhoff KS9570 is a buffer capacitor terminal designed to absorb regenerative energy and stabilize supply voltages in dynamic drive systems, protecting upstream components from overvoltage.

Which external braking resistor is recommended for the KS9570?

The recommended external braking resistor for use with the KS9570 terminal is the Beckhoff ZB8110.

What is the electrical isolation rating of this terminal?

The KS9570 features an electrical isolation of 1500 V between the K-bus and the field potential.

What wire sizes are compatible with the KS9570 terminal?

The terminal supports solid and stranded wires from 0.08 to 1.5 mm2 (AWG 28 to 16) and flexible wires from 0.14 to 1.5 mm2 (AWG 26 to 16).

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...