1 de 1

C9900-L100 Clé de licence clé USB pour TwinCAT 3.1

C9900-L100 Clé de licence clé USB pour TwinCAT 3.1

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : C9900-L100

  • Pays d'origine :Allemagne

  • Type de produit : Clé USB de licence pour TwinCAT 3.1

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Product Overview

The C9900-L100 (C9900L100) is a dedicated industrial hardware license carrier designed for the TwinCAT 3.1 software environment. In modern decentralized control architectures and complex machine installations, managing software licenses can be a challenge, especially when hardware is replaced in the field. The C9900-L100 acts as a portable hardware "dongle," allowing TwinCAT 3 licenses to be tied to the physical USB stick rather than a specific Industrial PC (IPC) or Embedded PC. This provides maximum flexibility for maintenance teams and machine builders, as the license remains active even if the controller hardware is swapped, ensuring zero downtime and simplified software asset management across global manufacturing sites.

Technical Configuration

The C9900-L100 features a robust, industrial-grade USB interface optimized for 24/7 operation in harsh environments. Unlike standard consumer-grade USB flash drives, this license carrier is engineered for high electromagnetic compatibility (EMC) and sustained vibration resistance, conforming to the mechanical requirements of industrial control cabinets. Once inserted into a USB 2.0 or 3.0 port of a Beckhoff IPC or CX series controller, the TwinCAT 3 runtime recognizes the unique hardware ID of the stick. Licenses are then activated against this ID, making the software portable and independent of the host PC's unique identifier.

Technical Specifications

Feature Specification
Model C9900-L100
Brand BECKHOFF
Device Type Hardware License Carrier (USB Stick)
Software Version Optimized for TwinCAT 3.1
Interface USB 2.0 (compatible with 3.0/3.1 ports)
Housing Industrial-grade composite/metal
Data Retention High-reliability internal memory for license storage
Origin Germany
Operating Temp 0 to 55 deg C
Shipping Weight 1.0 kg

Technical FAQs

Can I store standard project files or documentation on the C9900-L100?

The C9900-L100 is primarily a security and license carrier. While the system recognizes it as a hardware ID source, it is not intended for general-purpose file storage. Using the stick solely for license management ensures that the critical security certificates and license files are not accidentally overwritten or corrupted by other data.

What happens if the USB stick is removed while the machine is running?

TwinCAT 3.1 periodically checks for the presence of the license carrier. If the C9900-L100 is removed during operation, the TwinCAT runtime will eventually enter a "License Missing" state. This may trigger a system warning or stop the execution of logic depending on the safety and configuration settings of your specific project. It is recommended to secure the stick in an internal USB port or use a cable tie to prevent accidental disconnection.

Can one C9900-L100 hold multiple TwinCAT 3 licenses?

Yes. A single C9900-L100 can act as the carrier for multiple TwinCAT 3 license instances (e.g., PLC, NC, HMI, and various specialized functions). All licenses activated for that specific Hardware ID will be functional as long as the stick is connected to the active runtime.


Engineering & Installation Guide

  • Internal Port Selection: For maximum security and to prevent physical damage or unauthorized removal, it is best practice to install the C9900-L100 in an internal USB port (if available) within the Industrial PC housing. If using an external port on the front panel, ensure the environment is free from excessive mechanical impact.

  • License Activation Process: When activating licenses in the TwinCAT 3 "License Manager" tab, select "Hardware-Dongle" (C9900-L100) as the System ID source instead of the local "Target Hardware." This ensures the generated License Request File (.tsrq) is linked to the USB stick's unique serial number.

  • Firmware and Driver Stability: Ensure the host operating system has the correct TwinCAT 3.1 drivers installed to recognize industrial USB HID devices. In some Windows Embedded environments, USB power management settings should be configured to "Always On" to prevent the OS from putting the USB stick into sleep mode, which would cause a license timeout error.

 

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Argent
Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...