1 de 3

Module d'alimentation GE Fanuc Series 90-70 IC697PWR711M

Module d'alimentation GE Fanuc Series 90-70 IC697PWR711M

Il ne reste que 3 article(s) en stock
  • Fabricant : General Electric

  • N° de produit : IC697PWR711M

  • Pays d'origine :États-Unis

  • Type de produit : Module d'alimentation électrique

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 900g

  • Dimensions : 20 cm x 11,5 cm x 5,7 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Product Overview

The IC697PWR711M (IC697PWR711-M) is a high-performance, 100-Watt capacity power regulation module engineered by GE Fanuc for the advanced Series 90-70 programmable logic controller infrastructure. Functioning as the primary electrical baseplate engine, this module converts wide-range AC or DC input potentials into regulated triple-rail output voltages to drive complex processing substrates. Mission-critical industrial environments—including deep-pit mining extraction rigs, municipal thermal power generation facilities, and continuous chemical distillation operations—rely on the IC697PWR711M (IC697PWR711-M) to maintain high-integrity bus processing logic. By integrating onboard active power factor correction and comprehensive electronic overcurrent clamps, the device cushions sensitive central processing frames against raw grid fluctuations. This prevents unprogrammed logic resets, isolates downstream field inductive transients, and successfully reduces expensive facility unscheduled downtime.

Mechanical Design & Power Distribution Matrix

The underlying hardware topology, multi-rail distribution framework, and fault isolation loops of the IC697PWR711M power assembly govern its real-time operational safety margins.

  • Triple-Potential DC Power Sourcing: Delivers simultaneous, high-stability rails optimized for rack logic and instrumentation interfaces, feeding +5 VDC at up to 20 A for central microprocessors, +12 VDC at 2 A for local communication loops, and -12 VDC at 1 A for operational amplifier inputs.

  • Universal Input Voltage Stage: Houses an active rectifier front-end that accepts flexible nominal incoming power profiles, operating smoothly on 120/240 VAC (90 to 264 VAC utility lines) or 125 VDC (100 to 150 VDC battery banks).

  • Onboard Power Factor Correction: Utilizes internal solid-state filtering circuitry to maintain a power factor greater than 0.93 under full load, minimizing line harmonic injection back into the switchgear cabinet.

  • Integrated Hardware Protective Clamps: Employs precise crowbar overvoltage circuits on the +5 VDC line (tripping between 5.7 and 6.7 V) alongside fast-acting typical overcurrent thresholds at 21 A (+5 VDC), 3.5 A (+12 VDC), and 1.6 A (-12 VDC).

  • Extended Hold-up Retention Loop: Provides a minimum 21-millisecond ride-through buffer upon immediate loss of incoming AC utility power, ensuring the host CPU has adequate time to execute safe shut-down subroutines and preserve volatile memory tables.

Performance Specifications & Engineering Index

Engineering Metric Technical Specification Standard Values
Model Designation IC697PWR711M
Brand Manufacturer GE Fanuc / Emerson Automation Solutions
Control System Line Series 90-70 High-Performance PLC Platform
Module Classification 100-Watt Core Baseplate Power Supply Module
Nominal Input Ranges 120/240 VAC Nominal / 125 VDC Nominal
AC Operational Envelope 90 to 264 VAC, Single Phase (47 to 63 Hz Frequency Window)
DC Operational Envelope 100 to 150 VDC Continuous Battery Power Input
Power Consumption Profiles 135 Watts typical / 160 Watts Maximum Input Draw
Input Inrush Threshold 3 A Typical Half-Cycle Peak Current
Cumulative Output Power 100 Watts Maximum total shared across all 3 rails
Voltage Regulation Precision +5 VDC: 4.90 to 5.25 V / +12 VDC: 11.75 to 12.6 V / -12 VDC: -12.6 to -11.75 V
Diagnostic Status Cluster Dedicated LED indicators for active DC outputs and overload warnings
Operating Ambient Window 0 to 60 deg C Baseplate Ambient Operating Range
Storage Thermal Boundary -40 to +85 deg C Structural Storage Envelope
Atmospheric Humidity Limits 5 to 95 percent Non-Condensing Environmental Ranges

System Operations & Maintenance FAQs

How do engineers manage a vacancy left by a secondary rack power module in an expanded system?

When setting up multi-rack Series 90-70 architectures, engineers deploy the optional IC697CBL700 power supply extension cable kit. This package provides a heavy-duty interconnect cable along with a dedicated faceplate assembly designed to blank off and secure the vacant power supply slot within the expansion baseplate, ensuring proper panel aesthetics and grounding.

What behavioral changes indicate that the IC697PWR711M has entered an overcurrent condition?

The module features a front-mounted LED status array that constantly monitors load conditions. If a downstream module or communication bus draws current exceeding the 21 A clamp on the +5 VDC rail or the 3.5 A threshold on the +12 VDC line, the output rails shut down electronically to protect internal traces, and the front diagnostic LEDs toggle state to alert maintenance personnel of the field fault.

Can this power supply operate reliably when incoming line voltages drop below nominal levels for extended periods?

Yes, but you must consult the factory derating profiles (such as those outlined in standard engineering document GFK-0867B). Running continuously at the absolute lower input bound of 90 VAC decreases the thermal dissipation efficiency of the internal switching elements. To maintain long-term reliability without premature capacitor aging, engineers must derate the total active output power below the 100-Watt threshold.


Engineering & Installation Guide

  • Chassis Grounding Paths and Backplane Locking:

    Mount the IC697PWR711M strictly into the leftmost slot of the Series 90-70 rack chassis. Ensure the upper and lower structural alignment teeth slide fully into the backplane frame slots, and press until the module seats firmly. Tighten all exterior frame securement screws to 0.7 N-m (6.2 inch-lbs). This establishing a low-impedance connection to the common panel earth ground, which is vital for bleeding off high-frequency electromagnetic interference before it impacts signal stability.

  • Input Power Terminal Separation and Safety Shrouding:

    When landing field supply conductors onto the input terminals, use separate, high-temperature wires for AC lines or DC battery feeds. Route these supply loops away from low-voltage I/O lines to avoid capacitive noise coupling. Ensure all terminal connection blocks are protected behind their integrated plastic swing-doors to guard against accidental contact by personnel during routing diagnostics.

  • Thermal Management Clearances and Airflow Routing:

    The 100-Watt power supply generates steady convective heat during continuous operations at full load. Maintain a minimal open clearance gap of 7.5 cm above and below the baseplate chassis assembly inside the cabinet. Periodically clean dust or particulates away from the lower louvers to ensure unrestricted upward airflow, keeping the ambient air around the components safely within the certified 0 to 60 deg C operating window.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Noir
Country of origin
États-Unis
Power source
Alimenté par courant alternatif Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...