1 de 3

Carte collecteur d'excitateur General Electric IS200ESELH1AAA

Carte collecteur d'excitateur General Electric IS200ESELH1AAA

Il ne reste que 3 article(s) en stock
  • Fabricant : General Electric

  • N° de produit : IS200ESELH1A

  • Pays d'origine :États-Unis

  • Type de produit : Exciter Collector Board

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 850g

  • Dimensions : 25 mm x 330 mm x 178 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The IS200ESELH1AAA serves as an exciter collector board developed for the Mark VI Speedtronic control platform. This electronic assembly functions primarily within turbine control systems to handle continuous management parameters for steam and gas turbines. Operating within either a Simplex infrastructure or a Triple Modular Redundant (TMR) structural setup, the IS200ESELH1AAA receives logic-level gate pulses directly from a linked VME-based EMIO input/output management card. The module interfaces with up to six distinct gate pulse signals, routing these outputs onward to an external EGPA exciter gate pulse amplifier board positioned inside a separate enclosure cabinet. Built with integrated voltage suppression and circuit limitation components spanning over 200 resistors, diodes, transistors, and integrated circuits, this conformal-coated printed circuit board ensures clean data execution pathways across dual multi-pin backplane connectors.

Features

  • Receives up to six distinct logic-level gate pulse signals directly from a host VME-style EMIO management unit.
  • Routes processed gating information to a separate cabinet-mounted EGPA exciter gate pulse amplifier module.
  • Deploys integrated voltage suppression architecture using a network of over 200 resistors, capacitors, transistors, and diodes.
  • Features a slim physical faceplate equipped with three status LEDs designated for Power, Active, and Gating monitoring.
  • Adapts dynamically to simple system configurations using one unit, or TMR setups utilizing two boards driven by M1 and M2 links.
  • Features specialized industrial conformal PCB insulation coating across the active surface layer for hardware durability.

Applications

  • Mark VI Speedtronic Systems: Directing gate pulse synchronization tasks for utility-scale gas and steam turbine controls.
  • Excitation Controls: Interfacing interface logic maps between primary input/output blocks and external gate pulse amplifiers.
  • TMR Redundant Operations: Functioning as an isolated pulse capture node driven concurrently by distinct controller processors.

Technical Specifications

Parameter Value
Manufacturer General Electric
Functional Code / Part Number IS200ESELH1AAA
Functional Abbreviation ESEL
Series Mark VI Speedtronic
Product Type Exciter Collector Board
Assembly Style Normal Assembly
Total Product Revisions 3 Revisions
Backwards Compatibility First two revisions compatible
PCB Coating Treatment Conformal Coated
Input Signal Capability Up to 6 gate pulse inputs
Interface Hardware 2 x Backplane Connectors
Status Indicators 3 x Faceplate LEDs (Power, Active, Gating)
Weight 0.85 KG
Dimensions (W x H x D) 25 mm x 330 mm x 178 mm

 

Connections/Interfaces

Connector Type Function
Backplane Connectors (Dual) Provides bus interface paths and power links within the rack enclosure

 

Installation Guidelines

  • Turn off all main power paths going to the Mark VI turbine control chassis before inserting the module.
  • Slide the board evenly along the designated rack tracks until the dual backplane connectors link fully into the receiver frame.
  • Fasten the top and bottom mounting clips securely over the enclosure frame to prevent loose contact faults.
  • Verify correct tracking behaviors across the faceplate panel by evaluating the Power, Active, and Gating LEDs during system initialization.
Loading product navigation…

Are all three A-rated hardware revisions of the module completely identical?

No. Only the first two A-rated product revisions share identical revision styles to maintain backwards compatibility within the system series.

What functional components drive the module in a triple modular redundant setup?

In a TMR infrastructure, a pair of these units is required, where one board is driven directly by the M1 link and the other board interfaces with the M2 link.

What do the three integrated faceplate indicators monitor?

The three top-mounted LEDs provide clear, local status monitoring for system power, active board status, and active signal gating loops.

From which internal hardware card does the device receive its gate inputs?

The board receives up to six logic-level gate pulse inputs from a connected VME-based EMIO interface module.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Vert
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...