1 de 1

KL4001 BECKHOFF Terminal bus Sortie analogique 1 canal 0-10V

KL4001 BECKHOFF Terminal bus Sortie analogique 1 canal 0-10V

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : KL4001

  • Pays d'origine :Allemagne

  • Type de produit : Bornier de bus

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Product Overview

The KL4001 (KL 4001) is a precision 1-channel analog output terminal designed to transmit analog voltage signals in the 0 to 10 V range. Utilizing a 12-bit resolution and a differential output architecture, this Bus Terminal is engineered for highly accurate control of actuators, frequency inverters, and proportional valves. In demanding industrial sectors such as HVAC regulation, chemical processing, and specialized machine building, the KL4001 serves as a vital control link. Its potential-free output and 500 V electrical isolation between the K-bus and signal voltage ensure superior noise immunity and signal stability, protecting the central controller from field-level electrical interference and preventing ground loops in complex automation networks.

Technical Configuration

The KL4001 architecture is optimized for reliability and precision. It converts digital 16-bit values from the controller into an analog voltage with an output error of less than ±0.1%, ensuring high fidelity in setpoint transmission. The terminal features a conversion time of approximately 1.5 ms and is designed to drive loads greater than 5 kΩ with short-circuit protection. As a standard Bus Terminal, it draws its power directly from the K-bus (typ. 75 mA) and requires no external power contacts. Its "differential" design allows the signal to be measured against its own reference point rather than a shared ground, which is critical for maintaining accuracy over longer cable runs or in environments with fluctuating ground potentials.

Technical Specifications

Attribute Specification Details
Model KL4001
Brand BECKHOFF
Origin Germany
Number of Outputs 1 (Differential)
Signal Voltage 0 to 10 V
Resolution 12 bit
Output Error < ±0.1 % (Relative to end value)
Conversion Time ~ 1.5 ms
Load > 5 kΩ (Short-circuit proof)
Electrical Isolation 500 V (K-bus / Signal voltage)
Current Consumption Typ. 75 mA (K-bus)
Operating Temperature -25 to +60 deg C
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Protection Rating IP20
Weight 85 g
Shipping Weight 2.0 kg
Approvals CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)

Technical FAQs

Does the KL4001 require any software configuration for basic operation?

No, the KL4001 is designed for immediate integration. It uses 1 x 16-bit data in the process image (with an optional 8-bit control/status byte) and does not require manual address or configuration settings, allowing for a seamless "plug-and-play" experience within the TwinCAT environment.

What is the benefit of the potential-free output?

The potential-free output ensures that the signal voltage is electrically isolated from the internal logic and other terminals. This prevents interference from other modules in the terminal segment and eliminates the risk of ground loops that could distort the 0-10 V signal or damage sensitive analog actuators.

How does the KL4001 handle short circuits on the output line?

The module is short-circuit proof. If a short occurs on the signal line, the terminal limits the current to prevent internal hardware damage. Once the fault is cleared, the terminal resumes standard analog output operation without requiring a hardware reset.


Engineering & Installation Guide

Wiring and Signal Grounding:

To achieve the maximum precision of < ±0.1% error, use shielded twisted-pair cabling for the 0-10 V output. The shield should be grounded only at one end (typically at the control cabinet's entry point) to avoid circulating currents. Ensure the stripping length is 8–9 mm for the spring-loaded terminals to guarantee a gas-tight connection. For the differential output of the KL4001, the signal (+) and signal (-) should be connected directly to the high-impedance input (> 5 kΩ) of the receiving device.

Hazardous Area Compliance:

The KL4001 is ATEX rated (Ex nA IIC T4 Gc) for use in Zone 2 hazardous areas. When installing in these environments, the terminal must be mounted in an IP54-rated enclosure and the 35 mm DIN rail must be connected to a clean functional earth. Do not unplug the terminal or disconnect any wiring while the K-bus power is active to prevent potential ignition sources.

Thermal Management and Mounting:

The terminal is rated for operation from -25 to +60 deg C. To ensure long-term stability of the analog conversion circuitry, maintain a minimum vertical clearance of 30 mm above and below the module for airflow. When mounting side-by-side, the double slot and key connection provides the necessary mechanical stability. If the module is used at the end of a segment, ensure a KL9010 bus end terminal is installed to terminate the K-bus correctly.

 

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...