Providing dedicated human-machine visualization, the Omron NS10-TV00B-V1 serves as a high-resolution graphical operator interface designed for real-time monitoring and control inside automated industrial systems. This model features a robust 10.4-inch TFT active matrix display integrated with a highly responsive touchscreen interface, enabling intuitive system diagnostics and process management. Encased in a black bezel housing, the device is engineered with built-in serial and USB ports to ensure seamless connectivity within multi-node PLC architectures.

Features

  • High-durability TFT color LCD screen displaying up to 256 colors for clear, high-contrast diagnostics.
  • Dual integrated RS-232C serial communication ports enabling direct, simultaneous PLC and peripheral interfacing.
  • Dedicated CompactFlash slot for automated screen project backup, event logging, and recipe data storage.
  • USB host and slave interfaces supporting seamless PC programming via CX-Designer and auxiliary data transfer.
  • Modular expansion capability via dedicated rear-panel option slot for Ethernet or Controller Link modules.

Applications

  • Automotive body shop assembly lines and conveyor system visualization.
  • Packaging machinery, palletizers, and material handling systems.
  • Water treatment processing and pump control monitoring stations.
  • Food and beverage batching, mixing, and heating processes.

Technical Specifications

Manufacturer Omron
Model Reference NS10-TV00B-V1
Display Type TFT Color Active Matrix LCD
Screen Size (Diagonal) 10.4 inches
Resolution 640 x 480 pixels (VGA)
Display Colors 256 colors
Rated Input Voltage 24 VDC
Allowable Voltage Range 20.4 to 27.6 VDC
Power Consumption 25 W maximum
Serial Communications 2 x RS-232C ports (9-pin D-sub)
USB Ports 1 x USB Type B (Slave, USB 1.1)
Expansion Slot 1 x Slot (for network interfaces or video input board)
Storage Medium CompactFlash Slot (Type I/II)
Operating Temperature 0 to 50 degC
Ambient Humidity 35% to 85% RH (non-condensing)
Bezel Color Black
Shipping Weight (Calculated) 3.5 kg

Connections and Interfaces

Interface Connection Physical Connector Signal / Function Assignment
Serial Port A 9-pin D-sub (Female) Host Link / NT Link (1:1 or 1:N) protocol interface
Serial Port B 9-pin D-sub (Female) Host Link, NT Link, or temperature controller serial link
USB Slave USB Type B Direct PC programming and screen data transfer
Power Terminals 3-position terminal block 24 VDC (+), 0 VDC (-), Functional Ground (GR)

Empirical Engineering Insights

Alternative Models & Compatibility

The legacy non-V1 version and the updated V1 module are mount-compatible, utilizing identical cabinet cutouts. Note that screen projects compiled for V1 hardware require updating the target HMI system program in CX-Designer before performing a serial or USB download to prevent runtime initialization faults.

Application Pitfalls & Engineering Notes

Thermal behavior inside small, unventilated enclosures can accelerate backlight aging. Always maintain a minimum clearance of 100 mm around all rear chassis surfaces. Do not use standard consumer-grade MLC CompactFlash cards; write endurance limits will trigger localized sectors to corrupt under heavy data-logging cycles. Standardize on SLC industrial-grade media.

Commissioning & Wiring Tips

When wiring high-speed NT Link serial configurations over long distances, route serial runs strictly away from high-current AC motor leads to reduce electromagnetic interference. Ground loops are common if functional ground terminals are bridged back to industrial drive bus commons. Ensure functional ground (GR) is terminated directly to the main cabinet star ground plate.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL RISK

Isolate and lock out all AC/DC power sources feeding the enclosure panel prior to preparing cutouts, executing physical installation, or terminating control wiring. Failure to do so may result in device damage, internal circuit failure, or high-voltage shock.

1
Prepare Panel Cutout: Trace and cut a clear rectanglar opening of 302.0 mm x 228.0 mm (tolerance +1.0 / -0.0 mm) in the enclosure door. Ensure panel thickness is between 1.6 mm and 4.8 mm.
2
Verify Bezel Gasket: Confirm that the waterproof rubber sealing gasket is seated flat inside the outer perimeter groove of the HMI bezel. This is critical to maintain IP65-equivalent protection.
3
Secure Mounting Brackets: Insert the device from the front of the panel cutout, then slide the mounting brackets into the side tracks from behind. Progressively tighten the screws with a torque of 0.5 to 0.6 N-m to ensure an even seal without cracking the bezel.
4
Terminate Power & Ground: Connect 24 VDC power lines using 2 mm2 cross-section wires. Wire the Functional Ground terminal using a green/yellow earth lead directly to the main system electrical ground point.
Loading product navigation…

What configuration tool is required for programming the NS10-TV00B-V1?

The HMI must be configured using Omron CX-Designer software, which is distributed as a component of the standard CX-One automation suite.

Are the older NS10 units cross-compatible with the V1 model?

Yes. The physical footprint, cutout dimensions, and electrical inputs match older units, but you must select the V1 hardware profile in CX-Designer before downloading existing screen programs.

Can the LCD backlight assembly on this screen be replaced?

Yes, the backlight on the NS10-TV00B-V1 HMI is designed to be field-replaceable. Utilize only genuine Omron replacement backlight kits to ensure durability.

What type of storage cards should be used in the integrated card slot?

The device features a CompactFlash (CF) Type I/II slot. For high reliability in data logging and firmware storage, always specify industrial-grade SLC CompactFlash cards.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...