1 de 1

Siemens 6ES7647-6BB10-0GB1 SIMATIC Box PC 627B Industrial PC

Siemens 6ES7647-6BB10-0GB1 SIMATIC Box PC 627B Industrial PC

Il ne reste que 4 article(s) en stock
  • Fabricant : Siemens

  • N° de produit : 6ES7647-6BB10-0GB1

  • Pays d'origine :Allemagne

  • Type de produit : Industrial PC

  • Code-barres : 84715000

  • Paiement : Virement bancaire, Western Union

  • Poids : 7g

  • Dimensions : 120.5 x 50.5 x 10.0 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Siemens 6ES7647-6BB10-0GB1 is a SIMATIC Box PC 627B designed for robust performance in industrial environments. This unit is equipped with an Intel Celeron M 440 processor running at 1.86 GHz, 512 MB of DDR2 RAM, and a RAID1 storage configuration consisting of two 250 GB SATA hard drives for data redundancy. Connectivity is provided through dual Gigabit Ethernet ports, four high-current USB 2.0 ports, a serial COM port, and an integrated PROFIBUS/MPI interface. The system includes onboard monitoring for temperature and fan status, a watchdog timer for operational reliability, and is powered by a 110/230V AC industrial power supply. This model is pre-installed with Windows XP Professional and includes SIMATIC PC DiagMonitor software. Please note that this product line is designated as obsolete by the manufacturer.

Features

  • Powered by an Intel Celeron M 440 processor with a 533 MHz Front Side Bus.
  • Onboard RAID1 controller with two 250 GB SATA hard drives for enhanced data protection.
  • Integrated PROFIBUS/MPI interface for direct field-level communication.
  • Dual 10/100/1000 Mbit/s Ethernet ports for network redundancy or segmentation.
  • System health monitoring with integrated watchdog, temperature, and fan sensors.
  • Four high-current USB 2.0 ports for connecting peripherals.
  • Two available PCI slots for hardware expansion.
  • Front-accessible CompactFlash slot for removable storage or system backup.

Applications

  • PC-based automation and control systems
  • Human-Machine Interface (HMI) server applications
  • Data acquisition, logging, and gateway functions
  • Manufacturing Execution Systems (MES) interface
  • Industrial image processing and quality control

Technical Specifications

Category Specification
Processor Intel Celeron M 440 (1.86 GHz, 1 MB L2 Cache, 533 MHz FSB)
Memory 512 MB DDR2 667 SODIMM
Buffered Memory 2 MB Buffered SRAM
Storage RAID1 Configuration: 2x 250 GB SATA (2.5")
Graphics Onboard, 128 MB Shared Memory
Interfaces 2x 10/100/1000 Mbit/s Ethernet (RJ45)
4x USB V2.0 (High Current)
1x Serial (COM1)
1x PROFIBUS/MPI
Expansion Slots 2x PCI (free)
Removable Media 1x CompactFlash Drive Slot (front-side, without CF card)
Power Supply AC 110/230V Industrial Power Supply with NAMUR
System Monitoring Watchdog, Temperature Monitoring, Fan Monitoring
Operating System Windows XP Professional SP2 (Multi-language)
Included Software SIMATIC PC DiagMonitor Software V3.1
Product Lifecycle Status Obsolete
Manufacturer Siemens
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 120.5 x 50.5 x 10.0 cm
Shipping Weight 7.00 kg
Commodity Code 84715000
ECCN 5D992

Installation Guidelines

CRITICAL WARNING: Electrical Hazard. Disconnect all power sources before installation or maintenance. This equipment must be installed and serviced by qualified personnel only, in accordance with all applicable safety standards and regulations. Failure to comply can result in severe injury or death.
  1. 1 Ensure the mounting location provides adequate ventilation and is free from excessive vibration, moisture, and corrosive contaminants. Maintain specified ambient operating temperature ranges.
  2. 2 Securely mount the Box PC chassis to a stable panel or surface using all provided mounting points. Verify the unit is mechanically stable before connecting any wiring.
  3. 3 Connect the chassis to a dedicated protective earth (PE) ground point using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.
  4. 4 Connect the AC power supply cable to a stable, correctly rated power source. Use a circuit with appropriate overcurrent protection.
  5. 5 Connect all communication and I/O cables (Ethernet, PROFIBUS, USB, Serial). Ensure proper cable shielding is terminated correctly at the connector or chassis ground to minimize electromagnetic interference.
  6. 6 After verifying all connections are secure and correct, re-apply power to the unit and proceed with system configuration and software setup.

What processor is installed in the 6ES7647-6BB10-0GB1?

This SIMATIC Box PC is equipped with an Intel Celeron M 440 processor, which operates at 1.86 GHz and has a 1 MB L2 cache and a 533 MHz front-side bus.

What is the storage configuration of this industrial PC?

The unit features an onboard RAID controller managing a RAID1 configuration, which includes two 2.5-inch 250 GB SATA hard drives for data mirroring and redundancy.

Does this Box PC support PROFIBUS communication?

Yes, this model includes an integrated PROFIBUS/MPI interface for direct connection to industrial automation networks.

What operating system is pre-installed on the device?

The PC comes with Windows XP Professional, Service Pack 2 (Multi-language version) pre-installed.

How many Ethernet ports does the 6ES7647-6BB10-0GB1 have?

It has two Gigabit Ethernet ports (10/100/1000 Mbit/s) with RJ45 connectors, allowing for network redundancy or connection to separate networks.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...